Practical single-phase power in a compact steel-frame package. Our BEGY motors use capacitor start–capacitor run (CSR) operation for high starting torque and good running performance, with a choice of foot, flange, or foot-and-flange mounting. Tell us about your application and we'll help you select the right configuration.
Our catalogue and listed selections cover 0.25–1.1 kW at two poles and 0.18–0.75 kW at four poles. The individual datasheets specify 240 V, single-phase, 50 Hz, direct-on-line starting and totally enclosed fan cooling. Our steel-frame product description specifies Class F insulation, S1 continuous duty, IP44 protection, IC411 cooling and manual overload protection, with a one-year warranty. Confirm the warranty terms and fitted protection for your purchase with us.
Before ordering: our website's headline range and some feature text differ from its selection table and attachments. The 0.18 kW four-pole entry also has conflicting frame and bearing details. We retain those differences below so you can confirm the exact motor with our team.
Choose your BEGY configuration
Our 10 listed selections are linked to their individual datasheets and the collected drawing sets. Each distinct PDF appears once in the detailed reference below. A shared archive includes several ratings and mountings; match the power, pole count, frame and mounting on the drawing before using its dimensions. An archive association alone does not prove that every member applies to every selection.
The drawings include IM1001 foot, IM2001 foot and flange, and IM3001 flange arrangements. Our catalogue calls the flange-only steel-frame series BETY; its designation remains unchanged in those tables.
| Row | Website specification | Datasheet | Drawings / archive members |
|---|---|---|---|
| 403 | kW Rating: 0.25; Voltage: 240; Phases: 1; No. of Poles: 2; Frame Size: D71 | Datasheet-510.pdf | 13 drawings in shared set |
| 404 | kW Rating: 0.25; Voltage: 240; Phases: 1; No. of Poles: 4; Frame Size: D71 | Datasheet-516.pdf | 13 drawings in shared set |
| 405 | kW Rating: 0.37; Voltage: 240; Phases: 1; No. of Poles: 2; Frame Size: D71 | Datasheet-511.pdf | 13 drawings in shared set |
| 406 | kW Rating: 0.37; Voltage: 240; Phases: 1; No. of Poles: 4; Frame Size: D71 | Datasheet-517.pdf | 13 drawings in shared set |
| 407 | kW Rating: 0.55; Voltage: 240; Phases: 1; No. of Poles: 2; Frame Size: D71 | Datasheet-512.pdf | 13 drawings in shared set |
| 408 | kW Rating: 0.55; Voltage: 240; Phases: 1; No. of Poles: 4; Frame Size: D80 | Datasheet-518.pdf | 8 drawings in shared set |
| 409 | kW Rating: 0.75; Voltage: 240; Phases: 1; No. of Poles: 2; Frame Size: D80 | Datasheet-513.pdf | 8 drawings in shared set |
| 410 | kW Rating: 0.75; Voltage: 240; Phases: 1; No. of Poles: 4; Frame Size: D80 | Datasheet-519.pdf | 8 drawings in shared set |
| 411 | kW Rating: 1.10; Voltage: 240; Phases: 1; No. of Poles: 2; Frame Size: D80 | Datasheet-514.pdf | 8 drawings in shared set |
| 412 | kW Rating: 0.18; Voltage: 240; Phases: 1; No. of Poles: 4; Frame Size: D63 | Datasheet-515.pdf | Available upon request |
Shared drawing set 1
Original archive membership; choose the matching rating and mounting.
Shared drawing set 2
Original archive membership; choose the matching rating and mounting.
CAD downloads: CADdrawings-517.zip · CADdrawings-519.zip
All 10 3D-drawing fields are available upon request. The 0.18 kW four-pole row also lists its PDF and CAD drawings as available upon request. Drawings naming 0.18 kW exist in other rows' shared archives, but we have not reassigned them to this row or treated them as a confirmed D63 outline. No software download is listed.
Built around your application
Start with your available supply, starting and running torque, operating duty, and mounting space. Our CSR motors use a start capacitor for starting torque and a run capacitor during operation. Exact speed, current, efficiency, torque, power factor and capacitor values are specific to each rating and remain in the tables below.
Our catalogue describes continuous operation at nameplate current, an ambient range of −10 to 40°C, and operation below 1,000 m altitude. Above those conditions, contact us about derating. Its standard specification lists non-hazardous environments, maximum 90% relative humidity, and belt or direct drive. Historical IEC34 and AS1359/1360 references remain with the catalogue; our website names IEC60034 and AS1359. These references are not a current certificate of approval.
For the catalogue's 71–80 frames, construction includes a rolled-steel frame, aluminium-alloy endshields with steel inserts, and a cast-iron drive-end endshield on frame 80. A bidirectional polypropylene fan, pressed-steel fan cover and terminal box, double-shielded pre-greased bearings, copper random-wound stator and dynamically balanced die-cast aluminium rotor complete the assembly. The catalogue describes Class F insulation and a centrifugal switch. It lists a deep-green Munsell 2.5G 6/3 finish and aluminium nameplate for these frames.
The terminal box is shown on the right when viewed from the drive-shaft end, with a left-side option. We can help confirm the available mounting and terminal-box arrangement. For direction changes, terminal connections and protection, follow the original diagrams and instructions for your motor; the catalogue's wiring groups distinguish motors up to 1.1 kW with thermal protection from larger dual-voltage motors. We have not reconstructed wiring from a text extract.
Use the dimensions for the selected mounting and source edition. The original outlines are marked typical dimensions only—ask us for certified dimensions before final installation. Catalogue dimensions are in millimetres; the individual outlines do not explicitly state general dimensional units, so their callouts are retained as printed. Blank entries are not zero or an invitation to infer a missing measurement.
Details to confirm with our team
Where our published information differs, we retain each source's wording or value and identify what needs confirmation.
- Range and construction: the website introduction states 0.18–0.75 kW and rolled-steel construction, but also includes “solid cast iron” wording. Its feature list gives 1.1–7.5 kW, frames 90S–132M and cast-iron construction. Those statements conflict with the BEGY catalogue and the page's own smaller-motor selections. The selection table includes 1.1 kW two-pole. Do not apply the larger cast-iron specifications or 240/480 V claims to these 240 V datasheets.
- 0.18 kW four-pole frame and bearings: the website row states D63; Datasheet-515 states D71, 7.5 kg, and 6201 ZZ at both ends. The catalogue uses A71, with 6202 ZZ at both ends. Its drawings are on request for that website row. An older A71 drawing marked “63 FLANGE” is a flange description, not proof that it matches the listed D63 motor.
- Datasheet weights: nine sheets—510–514 and 516–519—print 6202 ZZ or 6204 ZZ under “WEIGHT OF MOTOR / kgs”. These are nonnumeric source entries, not usable masses. Their literal entries remain in the source tables, with warnings. Catalogue approximate masses remain separate; we have not substituted them as verified datasheet weights.
- Frame designations: the datasheets use D71/D80, while the catalogue distinguishes A71, B71 and 80. Those labels remain separate; confirm the dimensional configuration rather than treating the prefixes as interchangeable.
- Power factor: the 0.37 kW two-pole Datasheet-511 gives 80% at full load; the catalogue gives 0.81 (81%). Both are retained.
- Terminal enclosure clearance: the four 71-frame foot drawings print 147 for the shaft-centre to terminal enclosure outer-edge callout; the corresponding catalogue AD entries are 114 mm. Confirm the envelope before allocating clearance.
- Flange fits and projection: individual flange drawings use h7 for the pilot, while the catalogue states N = js6. The three 80-frame flange-only drawings print register projection 3, versus 3.5 mm in the catalogue. Do not transfer these differences to the foot-and-flange drawings, which print 3.5.
- 80-frame flange-only axial lengths: the 0.75 kW two-pole / 0.55 kW four-pole outline prints flange-face-to-fan-end 285, versus catalogue LB 295 mm. The 0.75 kW four-pole and 1.1 kW two-pole outlines print 295, versus catalogue 315 mm. Overall lengths are retained separately. We have not adjusted dimensions to make a chain add up.
- Drawing labels: 0.37BF4 says “FOOT & FLANGE MOUNTED” but prints IM3001. The 0.75 kW two-pole / 0.55 kW four-pole flange file is named 0.75VB2 , 0.55BV4.pdf, while its title block says 0.75BV2. Original filenames and printed labels remain traceable.
- Insulation, cooling and operating limits: the steel-frame description and catalogue specify Class F; the conflicting website feature text mentions Class H/F materials. Datasheet insulation fields are blank. The catalogue prints IC0141 versus the website's IC411, distinguishes ±10% supply tolerance from ±5% for rated performance, and states both a 105°C Class F rise and a performance rise not exceeding 90°C by resistance method. Keep those statements in their original contexts.
| Selection / sheet | Field | Datasheet | Catalogue |
|---|---|---|---|
| 0.25 kW / 2P · Datasheet-510.pdf | Frame designation | D71 | A71 |
| 0.25 kW / 4P · Datasheet-516.pdf | Frame designation | D71 | A71 |
| 0.37 kW / 2P · Datasheet-511.pdf | POWER FACTOR / 100% LOAD | 80 % | 81.00 % |
| 0.37 kW / 2P · Datasheet-511.pdf | Frame designation | D71 | A71 |
| 0.37 kW / 4P · Datasheet-517.pdf | Frame designation | D71 | B71 |
| 0.55 kW / 2P · Datasheet-512.pdf | Frame designation | D71 | B71 |
| 0.18 kW / 4P · Datasheet-515.pdf | Frame designation | D71 | A71 |
Catalogue current/torque ratios and power factors were compared on the same percentage basis as the datasheets. Original ratios, supply pairs and frame labels remain unchanged below. Frame designation differences are retained as labels, not automatically treated as equivalent frames.
BEGY catalogue specifications
Our shared single-phase catalogue includes several product families. These tables retain shared operating context, the BEGY performance and spare-parts rows, and the steel-frame mounting schedules—including the flange-only BETY tables. BECY/BEDY and B56-only tables are excluded from this guide. Where a shared paragraph still names another family or voltage, it is explicitly scoped and does not extend the BEGY rating. Every catalogue page remains linked to its original edition.
Catalogue page 1 — Cover and whole-catalogue range; BEGY range stated in guide.
Catalogue range and navigation
Catalogue context / Range
| Property | Value | Unit |
|---|---|---|
| BEGY | Single Phase Motor, Type CSR; Series BEGY; Frame size 71–80; Output 0.18–1.1kW. |
Catalogue context
| Property | Value | Unit |
|---|---|---|
| Contents | Motor range p2; standard specification p3; general description p4; motor classification and selection p5; connection diagram p5; schematic drawings p6; terminal connection p6; performance data p7; dimension drawings IM1001 p8, IM3001 p9, IM2001 p10, B56 p11; spare parts p11; company addresses p12. |
Shared standard specification
Shared catalogue reference: this page also names other frame sizes, outputs, supplies and mountings. Those entries are not blanket BEGY specifications. Use the selected BEGY source and confirm any conflicting limits.
Ratings and specifications / Rating
| Property | Value | Unit |
|---|---|---|
| Voltage | Rated Voltage 240V/480V | |
| Frequency | Rated Frequency 50Hz | |
| Output range | 0.18kW – 7.5kW | |
| R.P.M. (Syn.) | 3000R.P.M. (2 Pole); 1500R.P.M. (4 Pole) | |
| Duty | S1 (Continuous) | |
| Frame size | 71 – 132M | |
| Enclosure | TEFC Totally Enclosed Fan Cooled | |
| Degree of protection | IP 44 (Totally Enclosed, Splash Proof) | |
| Method of cooling | IC 0141 External Fan. Surface Cooling | |
| Mounting | IM 1001 Foot Mounting; IM 3001 Flange Mounting; IM 2001 Foot & Flange Mounting |
Ratings and specifications / Application
| Property | Value | Unit |
|---|---|---|
| Power condition | Voltage ±10%, Frequency ±5%. | |
| Environment conditions | Area = Non Hazardous. Ambient Temperature −10°C to 40°C. Relative Humidity = Max. 90%. Altitude = Max. 1000m (3300ft). | |
| Drive method | Belt Drive or Direct Coupling | |
| Direction of rotation | Bi-Directional | |
| Method of starting | D.O.L. (Direct-On-Line) Full Voltage |
Ratings and specifications / Construction
| Property | Value | Unit |
|---|---|---|
| Frame | 71 – 80 Rolled Steel; 90 – 132 Cast Iron | |
| Endshield | 71 – 80 Alum. Alloy with Steel Insert, except Frame 80 DE (Cast Iron); 90 – 132 Cast Iron | |
| External fan | Polypropylene | |
| Fan cover | Pressed Steel | |
| Bearing | Single Row Deep Groove Ball Bearing – Double Shields, Pre-Greased | |
| Terminal box | Pressed Steel, with Clearance Hole Cable Entry | |
| Stator winding | Polyester Enamelled Copper Wires, Random Wound | |
| Insulation system | Class F (Operating Temp. 155°C – Temp. Rise 105°C) | |
| Rotor | Squirrel Cage. Alum. Conductor with End-Ring | |
| Painting | Phenolic Base Paint, Laquer Surface Finish; 71 – 80 Munsell 2.5G 6/3 (Deep Green); 90 – 132 Munsell N5.0 – SG (Grey) | |
| Name plate | 71 – 80 Aluminium; 90 – 132 Stainless Steel | |
| Bolts | ISO Metric System (Except B56) |
Ratings and specifications / Performance
| Property | Value | Unit |
|---|---|---|
| Temperature rise | Not Exceeding 90°C by Resistance Method | |
| Over speed | 125% Syn. R.P.M. for one min. | |
| Over torque | 160% Rated Torque for 15 sec. | |
| Capacitor start | Series BEGY/BETY and BECY/BEDY: Capacitor Start – Capacitor Run. Series B56: Cap. Start – Cap. Run and Cap. Start – Induction Run. | |
| Standards | Comply with relevant IEC & AS Standards |
Ratings, construction and options
Shared catalogue reference: this page also names other frame sizes, outputs, supplies and mountings. Those entries are not blanket BEGY specifications. Use the selected BEGY source and confirm any conflicting limits.
Catalogue context
| Property | Value | Unit |
|---|---|---|
| Connection | 240 Volts Single Phase 50Hz for motors of 0.18kW to 7.5kW. 240/480 Volts Single Phase 50Hz from 1.5 to 7.5kW. The motors will produce their rated performance with voltage +/−5 per cent. | |
| Rating | Continuously rated at name plate current defined as S1 to AS 1359 within an ambient temperature −10 to 40°C, and altitude below 1000 metres. For higher ambients and/or altitudes the output rating must be adjusted accordingly; contact TECO. | |
| Performance | Standard motors are designed with performance in accordance with relevant standards within IEC34 and AS 1359 & 1360. | |
| Direction of rotation | Suitable for operation in either direction. Reversing direction uses the connection link within the terminal box; source refers to page 6. Original diagrams remain the authority. | |
| Mounting | Foot: IM1001, 1011, 1031, 1051, 1061, 1071. Flange: IM3001, 3011, 3031. Foot and Flange: IM2001. According to AS 1359 and IEC72. | |
| Frame | Two pole motors up to 1.1kW, four pole motors up to 0.75kW and Series B56 motors are rolled steel. Larger motors are high-grade cast iron with longitudinal cooling fins and integrally cast feet. | |
| Fan and fan cowl | Bi-directional cooling fans of polypropylene; pressed-steel fan cowl painted internally and externally to resist corrosion. | |
| Bearings and lubrication | Double shielded, pre-packed ball bearings sealed against dust and moisture; source states no further attention for the life of the bearing. | |
| Stator winding and insulation | High-grade insulated cold-rolled electromagnetic steel laminations; Class F insulation system. Source states resistance to tropical and high-humidity conditions. All motors incorporate a centrifugal switch between the starting and running windings. | |
| Rotor assembly | One-piece pressure die-cast aluminium rotor conductors and end rings; rotating parts dynamically balanced to minimise vibration. | |
| Terminal box | Pressed steel terminal box at the right-hand side when looking at the drive shaft end; left-hand side optional. Connections shown on source page 6. | |
| Capacitors | BEGY 0.25–1.1kW (2P) and BECY 1.1kW (4P) to 7.5kW are capacitor start capacitor run. B56 0.75kW 2-pole and 0.25–0.55kW 4-pole are capacitor start induction run; B56 0.75kW 4-pole is capacitor start capacitor run. | |
| Paint finish | Castings and steel parts have a phenolic-base prime coat and synthetic enamel paint finish. |
Starting arrangements and selection
Shared catalogue reference: this page also names other frame sizes, outputs, supplies and mountings. Those entries are not blanket BEGY specifications. Use the selected BEGY source and confirm any conflicting limits.
Catalogue context
| Property | Value | Unit |
|---|---|---|
| Classification | CSIR = Capacitor Start – Induction Run. CSR = Capacitor Start – Capacitor Run. | |
| Selection | Selection depends on starting and running torque requirements, duty cycle and power-supply starting/running current limits. Source says TECO can manufacture single-phase motors for various applications. | |
| CSIR characteristics | High starting torque and medium starting current; source describes suitability for heavier duty applications and power supplies with higher voltage variation. | |
| CSR characteristics | Combines high starting torque and good running performance. Source describes use for integral-rating applications with heavier starting torque requirements. | |
| Source stock and protector note | Source states CSIR and CSR motors are stocked by TECO Australia, and single-voltage motors are normally fitted with thermal protectors. Historical catalogue statement; not current inventory proof. | |
| Connection diagram context | Separate C.C.W. and C.W. rotation diagrams for CSIR at 240V and CSR at 240V/480V. No wiring connections reconstructed; consult original page. |
Terminal connection reference
Shared catalogue reference: this page also names other frame sizes, outputs, supplies and mountings. Those entries are not blanket BEGY specifications. Use the selected BEGY source and confirm any conflicting limits.
Catalogue context
| Property | Value | Unit |
|---|---|---|
| Terminal connection context | Printed groups: 1.1kW and below with Thermal Protector (240V), and 1.5kW and above without Thermal Protector (240V/480V); C.C.W. and C.W. diagrams. Original diagrams govern connections; geometry is not encoded here. |
Schematic legend / Frame 71–80
| Property | Value | Unit |
|---|---|---|
| 1 | Fan Cover | part label |
| 2 | Fan | part label |
| 3 | End shield N-End | part label |
| 4 | Centrifugal Switch | part label |
| 5 | Stator Frame | part label |
| 6 | Stator | part label |
| 7 | Rotor | part label |
| 8 | End shield D-End | part label |
| 9 | Bearing | part label |
| 10 | Shaft | part label |
| 11 | Terminal Box | part label |
| 12 | Capacitor Box | part label |
BEGY performance data
Performance data
Conditions: Four printed row groups: main-range 2-pole, main-range 4-pole, B56 2-pole, B56 4-pole. A dash is preserved as a source dash, not zero. Only the listed frame/output/pole combination is covered; source association with a product does not make all rows applicable to that product. 240/480V supply distinctions and start/run capacitors remain separate. Notes/formulas are retained in the page commentary.
| Poles (poles) | Rated output (kW) | Frame size | Speed (RPM) | Efficiency (%) | Power factor cosφ (dimensionless) | Full-load current 240V (A) | Full-load current 480V (A) | Starting current ratio 240V (Ist/IN) | Starting current ratio 480V (Ist/IN) | Full-load torque (Nm) | Starting torque ratio (Tst/TN) | Breakdown torque ratio (Tb/TN) | Start capacitor (µF) | Start capacitor rated voltage (Vac) | Run capacitor (µF) | Run capacitor rated voltage (Vac) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2 | 0.25 | A71 | 2880 | 65.9 | 0.80 | 1.96 | — | 5.1 | — | 0.78 | 2.6 | 2.8 | 40 | 250 | 4 | 440 |
| 2 | 0.37 | A71 | 2870 | 72.4 | 0.81 | 2.66 | — | 4.9 | — | 1.27 | 2.3 | 2.3 | 50 | 250 | 5 | 440 |
| 2 | 0.55 | B71 | 2865 | 73 | 0.86 | 3.74 | — | 5.9 | — | 1.86 | 2.7 | 2.4 | 80 | 250 | 8 | 440 |
| 2 | 0.75 | 80 | 2900 | 74 | 0.87 | 4.84 | — | 7 | — | 2.45 | 3.2 | 2.8 | 100 | 250 | 10 | 440 |
| 2 | 1.1 | 80 | 2880 | 75.5 | 0.94 | 6.6 | — | 6.5 | — | 3.6 | 2.4 | 2.5 | 125 | 250 | 15 | 440 |
| 4 | 0.18 | A71 | 1430 | 63.5 | 0.72 | 1.7 | — | 4.7 | — | 1.18 | 2.7 | 2.4 | 40 | 250 | 4 | 440 |
| 4 | 0.25 | A71 | 1420 | 64.3 | 0.75 | 2.12 | — | 4.7 | — | 1.66 | 2.3 | 2.3 | 40 | 250 | 4 | 440 |
| 4 | 0.37 | B71 | 1415 | 68.7 | 0.78 | 2.9 | — | 5.2 | — | 2.45 | 2.2 | 2.3 | 70 | 250 | 6 | 440 |
| 4 | 0.55 | 80 | 1425 | 70.1 | 0.77 | 4.3 | — | 5.1 | — | 3.7 | 2.6 | 1.8 | 80 | 250 | 8 | 440 |
| 4 | 0.75 | 80 | 1425 | 72.1 | 0.86 | 5 | — | 5.8 | — | 5 | 2.5 | 2.2 | 100 | 250 | 12 | 440 |
Source conditions: Tolerances according to IEC 34-1 and AS 1359.60. Efficiency — 15(1−η)% when P2 ≤50kW. Power factor cosφ — (1−cosφ)/6, minimum 0.02, maximum 0.07. Torque TN = (9550 × kW)/RPM Nm. Data subject to change without notice.
Catalogue context
| Property | Value | Unit |
|---|---|---|
| Definitions and conversions | 1kW = 1.34HP; 1HP = 0.746kW; 1Nm = 0.102kgmf. Ist/IN = Starting Current/Nominal F.L. Current; Tst/TN = Starting Torque/Nominal F.L. Torque; Tb/TN = Break down Torque/Nominal F.L. Torque. |
Foot mounting IM1001
IM1001 overall and mounting dimensions
Conditions: Dimensions in mm unless an explicit inch, rating, part or mass unit is printed. Values in explicitly merged cells are repeated only within their source row span. Empty output cells remain blank, not an inferred additional variant. Geometry remains in the original. Design, data and dimensions subject to modification without notice.
| Series | Frame | Output 2P (kW) | Output 4P (kW) | Figure (figure reference) | A (mm) | AA (mm) | AB (mm) | AC (mm) | AD (mm) | AE (mm) | B (mm) | BA (mm) | BB (mm) | C (mm) | H (mm) | HA (mm) | HC (mm) | HD (mm) | HE (mm) | K (mm) | KK (mm) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BEGY | A71 | 0.25 | 0.18 | 1 | 112 | 40 | 150 | 144 | 114 | 86 | 90 | 30 | 120 | 45 | 71 | 3.2 | 177 | 31 | 10 | 22 | |
| BEGY | A71 | 0.37 | 0.25 | 1 | 112 | 40 | 150 | 144 | 114 | 86 | 90 | 30 | 120 | 45 | 71 | 3.2 | 182 | 31 | 10 | 22 | |
| BEGY | B71 | 0.37 | 1 | 112 | 40 | 150 | 144 | 114 | 86 | 90 | 30 | 120 | 45 | 71 | 3.2 | 182 | 31 | 10 | 22 | ||
| BEGY | B71 | 0.55 | 1 | 112 | 40 | 150 | 144 | 114 | 86 | 90 | 30 | 120 | 45 | 71 | 3.2 | 187 | 31 | 10 | 22 | ||
| BEGY | 80 | 0.75 | 0.55 | 1 | 125 | 40 | 165 | 163 | 122 | 94 | 100 | 30 | 130 | 50 | 80 | 3.2 | 205 | 40 | 10 | 22 | |
| BEGY | 80 | 0.75 | 1 | 125 | 40 | 165 | 163 | 122 | 94 | 100 | 30 | 130 | 50 | 80 | 3.2 | 205 | 40 | 10 | 22 | ||
| BEGY | 80 | 1.1 | 1 | 125 | 40 | 165 | 163 | 122 | 94 | 100 | 30 | 130 | 50 | 80 | 3.2 | 211 | 40 | 10 | 22 |
IM1001 shaft bearing and approximate mass
| Series | Frame | Output 2P (kW) | Output 4P (kW) | Figure (figure reference) | L (mm) | LE (mm) | LL (mm) | Z (mm) | D (mm) | E (mm) | ED (mm) | F (mm) | G (mm) | GA (mm) | Bearing D-END | Bearing ND-END | Approx. mass 2P (kg) | Approx. mass 4P (kg) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BEGY | A71 | 0.25 | 0.18 | 1 | 269 | 104 | 104 | 20 | 14 | 30 | 14 | 5 | 11 | 16 | 6202 ZZ | 6202 ZZ | 7.5 | 7.5 |
| BEGY | A71 | 0.37 | 0.25 | 1 | 269 | 104 | 104 | 20 | 14 | 30 | 14 | 5 | 11 | 16 | 6202 ZZ | 6202 ZZ | 8.3 | 8.5 |
| BEGY | B71 | 0.37 | 1 | 287 | 122 | 122 | 20 | 14 | 30 | 14 | 5 | 11 | 16 | 6202 ZZ | 6202 ZZ | 10 | ||
| BEGY | B71 | 0.55 | 1 | 287 | 122 | 122 | 20 | 14 | 30 | 14 | 5 | 11 | 16 | 6202 ZZ | 6202 ZZ | 9.7 | ||
| BEGY | 80 | 0.75 | 0.55 | 1 | 307 | 117 | 123 | 20 | 19 | 40 | 25 | 6 | 15.5 | 21.5 | 6204 ZZ | 6202 ZZ | 13.5 | 12 |
| BEGY | 80 | 0.75 | 1 | 307 | 117 | 123 | 20 | 19 | 40 | 25 | 6 | 15.5 | 21.5 | 6204 ZZ | 6202 ZZ | 14 | ||
| BEGY | 80 | 1.1 | 1 | 307 | 117 | 123 | 20 | 19 | 40 | 25 | 6 | 15.5 | 21.5 | 6204 ZZ | 6202 ZZ | 15.5 |
Flange mounting IM3001 — BETY catalogue designation
IM3001 flange dimensions
Conditions: Dimensions in mm unless an explicit inch, rating, part or mass unit is printed. Values in explicitly merged cells are repeated only within their source row span. Empty output cells remain blank, not an inferred additional variant. Geometry remains in the original. Design, data and dimensions subject to modification without notice. Series are BETY/BEDY on this page; not silently relabelled BEGY/BECY.
| Series | Frame | Output 2P (kW) | Output 4P (kW) | Figure (figure reference) | AD (mm) | AE (mm) | HB (mm) | HC (mm) | KK (mm) | L (mm) | LA (mm) | LB (mm) | M (mm) | N (mm) | P (mm) | S (mm) | T (mm) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BETY | A71 | 0.25 | 0.18 | 1 | 114 | 86 | 180 | 22 | 294 | 10 | 271 | 115 | 95 | 140 | 10 | 3 | |
| BETY | A71 | 0.25 | 1 | 114 | 86 | 186 | 22 | 301 | 10 | 271 | 130 | 110 | 160 | 10 | 3.5 | ||
| BETY | A71 | 0.37 | 1 | 114 | 86 | 191 | 22 | 301 | 10 | 271 | 130 | 110 | 160 | 10 | 3.5 | ||
| BETY | B71 | 0.37 | 1 | 114 | 86 | 191 | 22 | 319 | 10 | 289 | 130 | 110 | 160 | 10 | 3.5 | ||
| BETY | B71 | 0.55 | 1 | 114 | 86 | 196 | 22 | 319 | 10 | 289 | 130 | 110 | 160 | 10 | 3.5 | ||
| BETY | 80 | 0.75 | 0.55 | 1 | 122 | 94 | 225 | 22 | 325 | 12 | 295 | 165 | 130 | 200 | 12 | 3.5 | |
| BETY | 80 | 0.75 | 1 | 122 | 94 | 225 | 22 | 335 | 12 | 315 | 165 | 130 | 200 | 12 | 3.5 | ||
| BETY | 80 | 1.1 | 1 | 122 | 94 | 231 | 22 | 335 | 12 | 315 | 165 | 130 | 200 | 12 | 3.5 |
IM3001 shaft and bearing dimensions
Conditions: Dimensions in mm unless an explicit inch, rating, part or mass unit is printed. Values in explicitly merged cells are repeated only within their source row span. Empty output cells remain blank, not an inferred additional variant. Geometry remains in the original. Design, data and dimensions subject to modification without notice. Printed tolerance text: D = <28-j6, 38k6; F = h9; H = +0 −0.5; N = js6. Do not infer an unstated D=28 tolerance.
| Series | Frame | Output 2P (kW) | Output 4P (kW) | Figure (figure reference) | D (mm) | E (mm) | ED (mm) | F (mm) | G (mm) | GA (mm) | Bearing D-END | Bearing ND-END |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BETY | A71 | 0.25 | 0.18 | 1 | 11 | 23 | 10 | 4 | 8.5 | 12.5 | 6202 ZZ | 6202 ZZ |
| BETY | A71 | 0.25 | 1 | 14 | 30 | 14 | 5 | 11 | 16 | 6202 ZZ | 6202 ZZ | |
| BETY | A71 | 0.37 | 1 | 14 | 30 | 14 | 5 | 11 | 16 | 6202 ZZ | 6202 ZZ | |
| BETY | B71 | 0.37 | 1 | 14 | 30 | 14 | 5 | 11 | 16 | 6202 ZZ | 6202 ZZ | |
| BETY | B71 | 0.55 | 1 | 14 | 30 | 14 | 5 | 11 | 16 | 6202 ZZ | 6202 ZZ | |
| BETY | 80 | 0.75 | 0.55 | 1 | 19 | 40 | 25 | 6 | 15.5 | 21.5 | 6204 ZZ | 6202 ZZ |
| BETY | 80 | 0.75 | 1 | 19 | 40 | 25 | 6 | 15.5 | 21.5 | 6204 ZZ | 6202 ZZ | |
| BETY | 80 | 1.1 | 1 | 19 | 40 | 25 | 6 | 15.5 | 21.5 | 6204 ZZ | 6202 ZZ |
IM3001 tolerance
| Property | Value | Unit |
|---|---|---|
| D | <28-j6, 38k6 | |
| F | h9 | |
| H | +0 −0.5 | |
| N | js6 |
Drawing callout
| Property | Value | Unit |
|---|---|---|
| Flange figures 1–3 | 45° |
Foot and flange mounting IM2001
IM2001 foot and flange dimensions
Conditions: Dimensions in mm unless an explicit inch, rating, part or mass unit is printed. Values in explicitly merged cells are repeated only within their source row span. Empty output cells remain blank, not an inferred additional variant. Geometry remains in the original. Design, data and dimensions subject to modification without notice.
| Series | Frame | Output 2P (kW) | Output 4P (kW) | Figure (figure reference) | A (mm) | AA (mm) | AB (mm) | AD (mm) | AE (mm) | B (mm) | BA (mm) | BB (mm) | C (mm) | H (mm) | HA (mm) | HC (mm) | HD (mm) | HE (mm) | K (mm) | KK (mm) | L (mm) | LA (mm) | LB (mm) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BEGY | A71 | 0.25 | 0.18 | 1 | 112 | 40 | 150 | 114 | 86 | 90 | 30 | 120 | 77 | 71 | 3.2 | 177 | 31 | 10 | 22 | 301 | 10 | 271 | |
| BEGY | A71 | 0.25 | 1 | 112 | 40 | 150 | 114 | 86 | 90 | 30 | 120 | 77 | 71 | 3.2 | 177 | 31 | 10 | 22 | 301 | 10 | 271 | ||
| BEGY | A71 | 0.37 | 1 | 112 | 40 | 150 | 114 | 86 | 90 | 30 | 120 | 77 | 71 | 3.2 | 182 | 31 | 10 | 22 | 301 | 10 | 271 | ||
| BEGY | B71 | 0.37 | 112 | 40 | 150 | 114 | 86 | 90 | 30 | 120 | 77 | 71 | 3.2 | 182 | 31 | 10 | 22 | 319 | 10 | 289 | |||
| BEGY | B71 | 0.55 | 112 | 40 | 150 | 114 | 86 | 90 | 30 | 120 | 77 | 71 | 3.2 | 187 | 31 | 10 | 22 | 319 | 10 | 289 | |||
| BEGY | 80 | 0.75 | 0.55 | 1 | 125 | 40 | 165 | 122 | 94 | 100 | 30 | 130 | 77.5 | 80 | 3.2 | 205 | 40 | 10 | 22 | 335 | 12 | 295 | |
| BEGY | 80 | 0.75 | 1 | 125 | 40 | 165 | 122 | 94 | 100 | 30 | 130 | 77.5 | 80 | 3.2 | 205 | 40 | 10 | 22 | 355 | 12 | 315 | ||
| BEGY | 80 | 1.1 | 1 | 125 | 40 | 165 | 122 | 94 | 100 | 30 | 130 | 77.5 | 80 | 3.2 | 211 | 40 | 10 | 22 | 355 | 12 | 315 |
IM2001 flange shaft and bearing dimensions
| Series | Frame | Output 2P (kW) | Output 4P (kW) | Figure (figure reference) | LL (mm) | M (mm) | N (mm) | P (mm) | S (mm) | T (mm) | Z (mm) | D (mm) | E (mm) | ED (mm) | F (mm) | G (mm) | GA (mm) | Bearing D-END | Bearing ND-END |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BEGY | A71 | 0.25 | 0.18 | 1 | 104 | 130 | 110 | 160 | 10 | 3.5 | 20 | 14 | 30 | 14 | 5 | 11 | 16 | 6202 ZZ | 6202 ZZ |
| BEGY | A71 | 0.25 | 1 | 104 | 130 | 110 | 160 | 10 | 3.5 | 20 | 14 | 30 | 14 | 5 | 11 | 16 | 6202 ZZ | 6202 ZZ | |
| BEGY | A71 | 0.37 | 1 | 104 | 130 | 110 | 160 | 10 | 3.5 | 20 | 14 | 30 | 14 | 5 | 11 | 16 | 6202 ZZ | 6202 ZZ | |
| BEGY | B71 | 0.37 | 122 | 130 | 110 | 160 | 10 | 3.5 | 20 | 14 | 30 | 14 | 5 | 11 | 16 | 6202 ZZ | 6202 ZZ | ||
| BEGY | B71 | 0.55 | 122 | 130 | 110 | 160 | 10 | 3.5 | 20 | 14 | 30 | 14 | 5 | 11 | 16 | 6202 ZZ | 6202 ZZ | ||
| BEGY | 80 | 0.75 | 0.55 | 1 | 123 | 165 | 130 | 200 | 12 | 3.5 | 20 | 19 | 40 | 25 | 6 | 15.5 | 21.5 | 6204 ZZ | 6202 ZZ |
| BEGY | 80 | 0.75 | 1 | 143 | 165 | 130 | 200 | 12 | 3.5 | 20 | 19 | 40 | 25 | 6 | 15.5 | 21.5 | 6204 ZZ | 6202 ZZ | |
| BEGY | 80 | 1.1 | 1 | 143 | 165 | 130 | 200 | 12 | 3.5 | 20 | 19 | 40 | 25 | 6 | 15.5 | 21.5 | 6204 ZZ | 6202 ZZ |
BEGY spare parts
Spare parts list
Conditions: Dimensions in mm unless an explicit inch, rating, part or mass unit is printed. Values in explicitly merged cells are repeated only within their source row span. Empty output cells remain blank, not an inferred additional variant. Geometry remains in the original. Design, data and dimensions subject to modification without notice. Original kW–P column is split into output and pole count only. Capacitor ranges and x2/x4 multiplicity remain verbatim; no summed/replacement capacitor is inferred. Dashes are printed source dashes, not zeros.
| Type | Output (kW) | Poles (poles) | Centrifugal switch (part code) | Capacitor START | Capacitor RUN | Thermal overload (part code) | Bearing D-END | Bearing ND-END |
|---|---|---|---|---|---|---|---|---|
| BEGYBS | 0.18 | 4 | TS1RA4517 | 40uf 250V AC | 4uf 440V AC | MRA 68164 | 6202 ZZ | 6202 ZZ |
| BEGYBS | 0.25 | 2 | TS1RA2517 | 40uf 250V AC | 4uf 440V AC | MRA 68163 | 6202 ZZ | 6202 ZZ |
| BEGYBS | 0.25 | 4 | TS1RA4517 | 40uf 250V AC | 4uf 440V AC | MRA 68163 | 6202 ZZ | 6202 ZZ |
| BEGYBS | 0.37 | 2 | TS1RA2517 | 50uf 250V AC | 5uf 440V AC | MRA 68225 | 6202 ZZ | 6202 ZZ |
| BEGYBS | 0.37 | 4 | TS1RA4517 | 70uf 250V AC | 6uf 440V AC | MRA 68225 | 6202 ZZ | 6202 ZZ |
| BEGYBS | 0.55 | 2 | TS1RA2517 | 80uf 250V AC | 8uf 440V AC | MRA 68223 | 6202 ZZ | 6202 ZZ |
| BEGYBS | 0.55 | 4 | TS1RA4517 | 80uf 250V AC | 8uf 440V AC | MRA 68223 | 6204 ZZ | 6202 ZZ |
| BEGYBS | 0.75 | 2 | TS1RA2517 | 100uf 250V AC | 10uf 440V AC | MRA 68363 | 6204 ZZ | 6202 ZZ |
| BEGYBS | 0.75 | 4 | TS1RA4517 | 100uf 250V AC | 12uf 440V AC | MRA 68363 | 6204 ZZ | 6202 ZZ |
| BEGYBS | 1.1 | 2 | TS1RA2517 | 125uf 250V AC | 15uf 440V AC | MRA 68364 | 6204 ZZ | 6202 ZZ |
Catalogue page 12 — Historical contact back cover; current contact linked.
Individual datasheets and drawings
Each source retains its own ratings, missing fields and qualifications. The drawing sections also include 535 named dimensional callouts read from the 21 original outlines, including fits, shaft details, mounting holes and flange dimensions. Use the linked originals for geometry and datum positions; these tables do not replace a certified drawing.
0.18BE4 , 0.25BE2.pdf
Associated selection rows: 403, 404, 405, 406, 407
PDFdrawings-517.zip > 71 FRAME/A71/0.18BE4 , 0.25BE2.pdf.
Source page 1
Conditions for this section:
- C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| Identity / frame_as_printed | A71 | as printed | — |
| Drawing / Phase | 1 | as printed | C1 |
| Drawing / Construction | Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor | as printed | C1 |
| Drawing note / 1 | Foot mounted IM1001. | as printed | — |
| Drawing note / 2 | TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. | as printed | — |
| Drawing note / 3 | For belt or direct drive. | as printed | — |
Printed rating table — P049, 0.18BE4 , 0.25BE2.pdf, page 1
Conditions for this section:
- C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Configuration / printed row | POLES | kW | HP | SYNCH RPM | Conditions |
|---|---|---|---|---|---|
| 1 | 2 poles | 0.25 kW | 0.33 HP | 3000 rpm (synchronous, as headed) | C1 |
| 2 | 4 poles | 0.18 kW | 0.25 HP | 1500 rpm (synchronous, as headed) | C1 |
Dimensions read from this original outline
Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.
| Drawing callout | Printed value |
|---|---|
| Transverse mounting-hole centres | 112 |
| Foot overall width | 150 |
| Foot slot-group width callout | 40 |
| Foot thickness | 3.2 |
| Shaft height and tolerance | 71 +0/−0.5 |
| Lower terminal enclosure height above foot plane | 31 |
| Axial foot slot-group callout | 30 |
| Axial mounting-hole centres | 90 |
| Foot overall axial length | 120 |
| Cable-entry diameter | Ø22 |
| Shaft diameter and fit | Ø14 j6 |
| Key width | 5 |
| Shaft keyseat lower-height callout | 11 |
| Shaft-and-key top height | 16 |
| Shaft-end thread and depth | M5 TAP DEEP 7.5 |
| Foot slot detail: length × width | 20 × 10 |
| Shaft extension | 30 |
| Key length callout | 14 |
| Overall axial length | 269 |
| Shaft-centre to terminal enclosure outer edge | 147 |
| Shaft-centre to cable-entry axis | 86 |
| Front-view body width callout | 144 |
| Front-view overall vertical envelope | 177 |
| Shaft shoulder to nearer foot-hole centre | 45 |
| Rear foot-hole centre to fan end | 104 |
| Upper axial callout from fan end to drawn reference | 104 |
0.18BV4 , 0.25BV2.pdf
Associated selection rows: 403, 404, 405, 406, 407
PDFdrawings-517.zip > 71 FRAME/A71/0.18BV4 , 0.25BV2.pdf.
Source page 1
Conditions for this section:
- C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| Identity / frame_as_printed | A71 (63 FLANGE) | as printed | — |
| Drawing / Phase | 1 | as printed | C1 |
| Drawing / Construction | Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor | as printed | C1 |
| Drawing note / 1 | Flange mounted IM3001. | as printed | — |
| Drawing note / 2 | TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. | as printed | — |
| Drawing note / 3 | For belt or direct drive. | as printed | — |
Printed rating table — P049, 0.18BV4 , 0.25BV2.pdf, page 1
Conditions for this section:
- C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Configuration / printed row | POLES | kW | HP | SYNCH RPM | Conditions |
|---|---|---|---|---|---|
| 1 | 2 poles | 0.25 kW | 0.33 HP | 3000 rpm (synchronous, as headed) | C1 |
| 2 | 4 poles | 0.18 kW | 0.25 HP | 1500 rpm (synchronous, as headed) | C1 |
Dimensions read from this original outline
Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.
| Drawing callout | Printed value |
|---|---|
| Overall axial length | 294 |
| Flange face to fan end | 271 |
| Shaft extension | 23 |
| Key length callout | 10 |
| Shaft-centre to terminal enclosure outer edge | 114 |
| Shaft-centre to cable-entry axis | 86 |
| Front-view overall vertical envelope | 180 |
| Cable-entry diameter | Ø22 |
| Shaft diameter and fit | Ø11 j6 |
| Key width | 4 |
| Shaft keyseat lower-height callout | 8.5 |
| Shaft-and-key top height | 12.5 |
| Shaft-end thread and depth | M4 TAP DEEP 6 |
| Flange bolt pitch-circle diameter | Ø115 |
| Flange pilot diameter and fit | Ø95 h7 |
| Flange outer diameter | Ø140 |
| Flange bolt holes | 4-Ø10 Holes |
| Flange thickness | 10 |
| Flange register projection | 3 |
| Flange-hole angular offset | 45 |
0.25BF2 , 0.18BF4 , 0.25BF4.pdf
Associated selection rows: 403, 404, 405, 406, 407
PDFdrawings-517.zip > 71 FRAME/A71/0.25BF2 , 0.18BF4 , 0.25BF4.pdf.
Source page 1
Conditions for this section:
- C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| Identity / frame_as_printed | A71 | as printed | — |
| Drawing / Phase | 1 | as printed | C1 |
| Drawing / Construction | Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor | as printed | C1 |
| Drawing note / 1 | Foot & flange mounted IM2001. | as printed | — |
| Drawing note / 2 | TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. | as printed | — |
| Drawing note / 3 | For belt or direct drive. | as printed | — |
Printed rating table — P049, 0.25BF2 , 0.18BF4 , 0.25BF4.pdf, page 1
Conditions for this section:
- C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Configuration / printed row | POLES | kW | HP | SYNCH RPM | Conditions |
|---|---|---|---|---|---|
| 1 | 2 poles | 0.25 kW | 0.33 HP | 3000 rpm (synchronous, as headed) | C1 |
| 2 | 4 poles | 0.18/0.25 kW | 0.25/0.33 HP | 1500 rpm (synchronous, as headed) | C1 |
Dimensions read from this original outline
Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.
| Drawing callout | Printed value |
|---|---|
| Transverse mounting-hole centres | 112 |
| Foot overall width | 150 |
| Foot slot-group width callout | 40 |
| Foot thickness | 3.2 |
| Shaft height and tolerance | 71 +0/−0.5 |
| Lower terminal enclosure height above foot plane | 31 |
| Axial foot slot-group callout | 30 |
| Axial mounting-hole centres | 90 |
| Foot overall axial length | 120 |
| Cable-entry diameter | Ø22 |
| Shaft diameter and fit | Ø14 j6 |
| Key width | 5 |
| Shaft keyseat lower-height callout | 11 |
| Shaft-and-key top height | 16 |
| Shaft-end thread and depth | M5 TAP DEEP 7.5 |
| Foot slot detail: length × width | 20 × 10 |
| Shaft extension | 30 |
| Key length callout | 14 |
| Flange bolt pitch-circle diameter | Ø130 |
| Flange pilot diameter and fit | Ø110 h7 |
| Flange outer diameter | Ø160 |
| Flange bolt holes | 4-Ø10 Holes |
| Flange thickness | 10 |
| Flange register projection | 3.5 |
| Overall axial length | 301 |
| Flange face to fan end | 271 |
| Shaft-centre to terminal enclosure outer edge | 114 |
| Shaft-centre to cable-entry axis | 86 |
| Front-view overall vertical envelope | 177 |
| Axial front mounting offset as drawn | 77 |
| Rear foot-hole centre to fan end | 115 |
| Upper axial callout from fan end to drawn reference | 104 |
0.25BV4.pdf
Associated selection rows: 403, 404, 405, 406, 407
PDFdrawings-517.zip > 71 FRAME/A71/0.25BV4.pdf.
Source page 1
Conditions for this section:
- C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| Identity / frame_as_printed | A71 | as printed | — |
| Drawing / Phase | 1 | as printed | C1 |
| Drawing / Construction | Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor | as printed | C1 |
| Drawing note / 1 | Flange mounted IM3001. | as printed | — |
| Drawing note / 2 | TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. | as printed | — |
| Drawing note / 3 | For belt or direct drive. | as printed | — |
Printed rating table — P049, 0.25BV4.pdf, page 1
Conditions for this section:
- C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Configuration / printed row | POLES | kW | HP | SYNCH RPM | Conditions |
|---|---|---|---|---|---|
| 1 | 4 poles | 0.25 kW | 0.33 HP | 1500 rpm (synchronous, as headed) | C1 |
Dimensions read from this original outline
Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.
| Drawing callout | Printed value |
|---|---|
| Cable-entry diameter | Ø22 |
| Shaft diameter and fit | Ø14 j6 |
| Key width | 5 |
| Shaft keyseat lower-height callout | 11 |
| Shaft-and-key top height | 16 |
| Shaft-end thread and depth | M5 TAP DEEP 7.5 |
| Shaft extension | 30 |
| Key length callout | 14 |
| Flange bolt pitch-circle diameter | Ø130 |
| Flange pilot diameter and fit | Ø110 h7 |
| Flange outer diameter | Ø160 |
| Flange bolt holes | 4-Ø10 Holes |
| Flange thickness | 10 |
| Flange register projection | 3.5 |
| Flange-hole angular offset | 45 |
| Overall axial length | 301 |
| Flange face to fan end | 271 |
| Shaft-centre to terminal enclosure outer edge | 114 |
| Shaft-centre to cable-entry axis | 86 |
| Front-view overall vertical envelope | 186 |
0.37BE2 , 0.25BE4.pdf
Associated selection rows: 403, 404, 405, 406, 407
PDFdrawings-517.zip > 71 FRAME/A71/0.37BE2 , 0.25BE4.pdf.
Source page 1
Conditions for this section:
- C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| Identity / frame_as_printed | A71 | as printed | — |
| Drawing / Phase | 1 | as printed | C1 |
| Drawing / Construction | Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor | as printed | C1 |
| Drawing note / 1 | Foot mounted IM1001. | as printed | — |
| Drawing note / 2 | TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. | as printed | — |
| Drawing note / 3 | For belt or direct drive. | as printed | — |
Printed rating table — P049, 0.37BE2 , 0.25BE4.pdf, page 1
Conditions for this section:
- C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Configuration / printed row | POLES | kW | HP | SYNCH RPM | Conditions |
|---|---|---|---|---|---|
| 1 | 2 poles | 0.37 kW | 0.50 HP | 3000 rpm (synchronous, as headed) | C1 |
| 2 | 4 poles | 0.25 kW | 0.33 HP | 1500 rpm (synchronous, as headed) | C1 |
Dimensions read from this original outline
Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.
| Drawing callout | Printed value |
|---|---|
| Transverse mounting-hole centres | 112 |
| Foot overall width | 150 |
| Foot slot-group width callout | 40 |
| Foot thickness | 3.2 |
| Shaft height and tolerance | 71 +0/−0.5 |
| Lower terminal enclosure height above foot plane | 31 |
| Axial foot slot-group callout | 30 |
| Axial mounting-hole centres | 90 |
| Foot overall axial length | 120 |
| Cable-entry diameter | Ø22 |
| Shaft diameter and fit | Ø14 j6 |
| Key width | 5 |
| Shaft keyseat lower-height callout | 11 |
| Shaft-and-key top height | 16 |
| Shaft-end thread and depth | M5 TAP DEEP 7.5 |
| Foot slot detail: length × width | 20 × 10 |
| Shaft extension | 30 |
| Key length callout | 14 |
| Overall axial length | 269 |
| Shaft-centre to terminal enclosure outer edge | 147 |
| Shaft-centre to cable-entry axis | 86 |
| Front-view body width callout | 144 |
| Front-view overall vertical envelope | 182 |
| Shaft shoulder to nearer foot-hole centre | 45 |
| Rear foot-hole centre to fan end | 104 |
| Upper axial callout from fan end to drawn reference | 104 |
0.37BE4.pdf
Associated selection rows: 403, 404, 405, 406, 407
PDFdrawings-517.zip > 71 FRAME/B71/0.37BE4.pdf.
Source page 1
Conditions for this section:
- C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| Identity / frame_as_printed | B71 | as printed | — |
| Drawing / Phase | 1 | as printed | C1 |
| Drawing / Construction | Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor | as printed | C1 |
| Drawing note / 1 | Foot mounted IM1001. | as printed | — |
| Drawing note / 2 | TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. | as printed | — |
| Drawing note / 3 | For belt or direct drive. | as printed | — |
Printed rating table — P049, 0.37BE4.pdf, page 1
Conditions for this section:
- C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Configuration / printed row | POLES | kW | HP | SYNCH RPM | Conditions |
|---|---|---|---|---|---|
| 1 | 4 poles | 0.37 kW | 0.50 HP | 1500 rpm (synchronous, as headed) | C1 |
Dimensions read from this original outline
Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.
| Drawing callout | Printed value |
|---|---|
| Transverse mounting-hole centres | 112 |
| Foot overall width | 150 |
| Foot slot-group width callout | 40 |
| Foot thickness | 3.2 |
| Shaft height and tolerance | 71 +0/−0.5 |
| Lower terminal enclosure height above foot plane | 31 |
| Axial foot slot-group callout | 30 |
| Axial mounting-hole centres | 90 |
| Foot overall axial length | 120 |
| Cable-entry diameter | Ø22 |
| Shaft diameter and fit | Ø14 j6 |
| Key width | 5 |
| Shaft keyseat lower-height callout | 11 |
| Shaft-and-key top height | 16 |
| Shaft-end thread and depth | M5 TAP DEEP 7.5 |
| Foot slot detail: length × width | 20 × 10 |
| Shaft extension | 30 |
| Key length callout | 14 |
| Overall axial length | 287 |
| Shaft-centre to terminal enclosure outer edge | 147 |
| Shaft-centre to cable-entry axis | 86 |
| Front-view body width callout | 144 |
| Front-view overall vertical envelope | 182 |
| Shaft shoulder to nearer foot-hole centre | 45 |
| Rear foot-hole centre to fan end | 122 |
| Upper axial callout from fan end to drawn reference | 122 |
0.37BF2.pdf
Associated selection rows: 403, 404, 405, 406, 407
PDFdrawings-517.zip > 71 FRAME/A71/0.37BF2.pdf.
Source page 1
Conditions for this section:
- C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| Identity / frame_as_printed | A71 | as printed | — |
| Drawing / Phase | 1 | as printed | C1 |
| Drawing / Construction | Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor | as printed | C1 |
| Drawing note / 1 | Foot & flange mounted IM2001. | as printed | — |
| Drawing note / 2 | TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. | as printed | — |
| Drawing note / 3 | For belt or direct drive. | as printed | — |
Printed rating table — P049, 0.37BF2.pdf, page 1
Conditions for this section:
- C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Configuration / printed row | POLES | kW | HP | SYNCH RPM | Conditions |
|---|---|---|---|---|---|
| 1 | 2 poles | 0.37 kW | 0.50 HP | 3000 rpm (synchronous, as headed) | C1 |
Dimensions read from this original outline
Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.
| Drawing callout | Printed value |
|---|---|
| Transverse mounting-hole centres | 112 |
| Foot overall width | 150 |
| Foot slot-group width callout | 40 |
| Foot thickness | 3.2 |
| Shaft height and tolerance | 71 +0/−0.5 |
| Lower terminal enclosure height above foot plane | 31 |
| Axial foot slot-group callout | 30 |
| Axial mounting-hole centres | 90 |
| Foot overall axial length | 120 |
| Cable-entry diameter | Ø22 |
| Shaft diameter and fit | Ø14 j6 |
| Key width | 5 |
| Shaft keyseat lower-height callout | 11 |
| Shaft-and-key top height | 16 |
| Shaft-end thread and depth | M5 TAP DEEP 7.5 |
| Foot slot detail: length × width | 20 × 10 |
| Shaft extension | 30 |
| Key length callout | 14 |
| Flange bolt pitch-circle diameter | Ø130 |
| Flange pilot diameter and fit | Ø110 h7 |
| Flange outer diameter | Ø160 |
| Flange bolt holes | 4-Ø10 Holes |
| Flange thickness | 10 |
| Flange register projection | 3.5 |
| Overall axial length | 301 |
| Flange face to fan end | 271 |
| Shaft-centre to terminal enclosure outer edge | 114 |
| Shaft-centre to cable-entry axis | 86 |
| Front-view overall vertical envelope | 182 |
| Axial front mounting offset as drawn | 77 |
| Rear foot-hole centre to fan end | 115 |
| Upper axial callout from fan end to drawn reference | 104 |
0.37BF4.pdf
Associated selection rows: 403, 404, 405, 406, 407
PDFdrawings-517.zip > 71 FRAME/B71/0.37BF4.pdf.
Source differences and limitations
- Printed note says foot & flange mounted IM3001; wording and code retained together.
Source page 1
Conditions for this section:
- C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| Identity / frame_as_printed | B71 | as printed | — |
| Drawing / Phase | 1 | as printed | C1 |
| Drawing / Construction | Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor | as printed | C1 |
| Drawing note / 1 | Foot & flange mounted IM3001. | as printed | — |
| Drawing note / 2 | TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. | as printed | — |
| Drawing note / 3 | For belt or direct drive. | as printed | — |
Printed rating table — P049, 0.37BF4.pdf, page 1
Conditions for this section:
- C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Configuration / printed row | POLES | kW | HP | SYNCH RPM | Conditions |
|---|---|---|---|---|---|
| 1 | 4 poles | 0.37 kW | 0.50 HP | 1500 rpm (synchronous, as headed) | C1 |
Dimensions read from this original outline
Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.
| Drawing callout | Printed value |
|---|---|
| Transverse mounting-hole centres | 112 |
| Foot overall width | 150 |
| Foot slot-group width callout | 40 |
| Foot thickness | 3.2 |
| Shaft height and tolerance | 71 +0/−0.5 |
| Lower terminal enclosure height above foot plane | 31 |
| Axial foot slot-group callout | 30 |
| Axial mounting-hole centres | 90 |
| Foot overall axial length | 120 |
| Cable-entry diameter | Ø22 |
| Shaft diameter and fit | Ø14 j6 |
| Key width | 5 |
| Shaft keyseat lower-height callout | 11 |
| Shaft-and-key top height | 16 |
| Shaft-end thread and depth | M5 TAP DEEP 7.5 |
| Foot slot detail: length × width | 20 × 10 |
| Shaft extension | 30 |
| Key length callout | 14 |
| Flange bolt pitch-circle diameter | Ø130 |
| Flange pilot diameter and fit | Ø110 h7 |
| Flange outer diameter | Ø160 |
| Flange bolt holes | 4-Ø10 Holes |
| Flange thickness | 10 |
| Flange register projection | 3.5 |
| Overall axial length | 319 |
| Flange face to fan end | 289 |
| Shaft-centre to terminal enclosure outer edge | 114 |
| Shaft-centre to cable-entry axis | 86 |
| Front-view overall vertical envelope | 182 |
| Axial front mounting offset as drawn | 77 |
| Rear foot-hole centre to fan end | 122 |
| Upper axial callout from fan end to drawn reference | 122 |
0.37BV2.pdf
Associated selection rows: 403, 404, 405, 406, 407
PDFdrawings-517.zip > 71 FRAME/A71/0.37BV2.pdf.
Source page 1
Conditions for this section:
- C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| Identity / frame_as_printed | A71 | as printed | — |
| Drawing / Phase | 1 | as printed | C1 |
| Drawing / Construction | Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor | as printed | C1 |
| Drawing note / 1 | Flange mounted IM3001. | as printed | — |
| Drawing note / 2 | TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. | as printed | — |
| Drawing note / 3 | For belt or direct drive. | as printed | — |
Printed rating table — P049, 0.37BV2.pdf, page 1
Conditions for this section:
- C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Configuration / printed row | POLES | kW | HP | SYNCH RPM | Conditions |
|---|---|---|---|---|---|
| 1 | 2 poles | 0.37 kW | 0.50 HP | 3000 rpm (synchronous, as headed) | C1 |
Dimensions read from this original outline
Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.
| Drawing callout | Printed value |
|---|---|
| Cable-entry diameter | Ø22 |
| Shaft diameter and fit | Ø14 j6 |
| Key width | 5 |
| Shaft keyseat lower-height callout | 11 |
| Shaft-and-key top height | 16 |
| Shaft-end thread and depth | M5 TAP DEEP 7.5 |
| Shaft extension | 30 |
| Key length callout | 14 |
| Flange bolt pitch-circle diameter | Ø130 |
| Flange pilot diameter and fit | Ø110 h7 |
| Flange outer diameter | Ø160 |
| Flange bolt holes | 4-Ø10 Holes |
| Flange thickness | 10 |
| Flange register projection | 3.5 |
| Flange-hole angular offset | 45 |
| Overall axial length | 301 |
| Flange face to fan end | 271 |
| Shaft-centre to terminal enclosure outer edge | 114 |
| Shaft-centre to cable-entry axis | 86 |
| Front-view overall vertical envelope | 191 |
0.37BV4.pdf
Associated selection rows: 403, 404, 405, 406, 407
PDFdrawings-517.zip > 71 FRAME/B71/0.37BV4.pdf.
Source page 1
Conditions for this section:
- C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| Identity / frame_as_printed | B71 | as printed | — |
| Drawing / Phase | 1 | as printed | C1 |
| Drawing / Construction | Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor | as printed | C1 |
| Drawing note / 1 | Flange mounted IM3001. | as printed | — |
| Drawing note / 2 | TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. | as printed | — |
| Drawing note / 3 | For belt or direct drive. | as printed | — |
Printed rating table — P049, 0.37BV4.pdf, page 1
Conditions for this section:
- C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Configuration / printed row | POLES | kW | HP | SYNCH RPM | Conditions |
|---|---|---|---|---|---|
| 1 | 4 poles | 0.37 kW | 0.50 HP | 1500 rpm (synchronous, as headed) | C1 |
Dimensions read from this original outline
Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.
| Drawing callout | Printed value |
|---|---|
| Cable-entry diameter | Ø22 |
| Shaft diameter and fit | Ø14 j6 |
| Key width | 5 |
| Shaft keyseat lower-height callout | 11 |
| Shaft-and-key top height | 16 |
| Shaft-end thread and depth | M5 TAP DEEP 7.5 |
| Shaft extension | 30 |
| Key length callout | 14 |
| Flange bolt pitch-circle diameter | Ø130 |
| Flange pilot diameter and fit | Ø110 h7 |
| Flange outer diameter | Ø160 |
| Flange bolt holes | 4-Ø10 Holes |
| Flange thickness | 10 |
| Flange register projection | 3.5 |
| Flange-hole angular offset | 45 |
| Overall axial length | 319 |
| Flange face to fan end | 289 |
| Shaft-centre to terminal enclosure outer edge | 114 |
| Shaft-centre to cable-entry axis | 86 |
| Front-view overall vertical envelope | 191 |
0.55BE2.pdf
Associated selection rows: 403, 404, 405, 406, 407
PDFdrawings-517.zip > 71 FRAME/B71/0.55BE2.pdf.
Source page 1
Conditions for this section:
- C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| Identity / frame_as_printed | B71 | as printed | — |
| Drawing / Phase | 1 | as printed | C1 |
| Drawing / Construction | Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor | as printed | C1 |
| Drawing note / 1 | Foot mounted IM1001. | as printed | — |
| Drawing note / 2 | TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. | as printed | — |
| Drawing note / 3 | For belt or direct drive. | as printed | — |
Printed rating table — P049, 0.55BE2.pdf, page 1
Conditions for this section:
- C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Configuration / printed row | POLES | kW | HP | SYNCH RPM | Conditions |
|---|---|---|---|---|---|
| 1 | 2 poles | 0.55 kW | 0.75 HP | 3000 rpm (synchronous, as headed) | C1 |
Dimensions read from this original outline
Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.
| Drawing callout | Printed value |
|---|---|
| Transverse mounting-hole centres | 112 |
| Foot overall width | 150 |
| Foot slot-group width callout | 40 |
| Foot thickness | 3.2 |
| Shaft height and tolerance | 71 +0/−0.5 |
| Lower terminal enclosure height above foot plane | 31 |
| Axial foot slot-group callout | 30 |
| Axial mounting-hole centres | 90 |
| Foot overall axial length | 120 |
| Cable-entry diameter | Ø22 |
| Shaft diameter and fit | Ø14 j6 |
| Key width | 5 |
| Shaft keyseat lower-height callout | 11 |
| Shaft-and-key top height | 16 |
| Shaft-end thread and depth | M5 TAP DEEP 7.5 |
| Foot slot detail: length × width | 20 × 10 |
| Shaft extension | 30 |
| Key length callout | 14 |
| Overall axial length | 287 |
| Shaft-centre to terminal enclosure outer edge | 147 |
| Shaft-centre to cable-entry axis | 86 |
| Front-view body width callout | 144 |
| Front-view overall vertical envelope | 187 |
| Shaft shoulder to nearer foot-hole centre | 45 |
| Rear foot-hole centre to fan end | 122 |
| Upper axial callout from fan end to drawn reference | 122 |
0.55BF2.pdf
Associated selection rows: 403, 404, 405, 406, 407
PDFdrawings-517.zip > 71 FRAME/B71/0.55BF2.pdf.
Source page 1
Conditions for this section:
- C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| Identity / frame_as_printed | B71 | as printed | — |
| Drawing / Phase | 1 | as printed | C1 |
| Drawing / Construction | Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor | as printed | C1 |
| Drawing note / 1 | Foot & flange mounted IM2001. | as printed | — |
| Drawing note / 2 | TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. | as printed | — |
| Drawing note / 3 | For belt or direct drive. | as printed | — |
Printed rating table — P049, 0.55BF2.pdf, page 1
Conditions for this section:
- C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Configuration / printed row | POLES | kW | HP | SYNCH RPM | Conditions |
|---|---|---|---|---|---|
| 1 | 2 poles | 0.55 kW | 0.75 HP | 3000 rpm (synchronous, as headed) | C1 |
Dimensions read from this original outline
Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.
| Drawing callout | Printed value |
|---|---|
| Transverse mounting-hole centres | 112 |
| Foot overall width | 150 |
| Foot slot-group width callout | 40 |
| Foot thickness | 3.2 |
| Shaft height and tolerance | 71 +0/−0.5 |
| Lower terminal enclosure height above foot plane | 31 |
| Axial foot slot-group callout | 30 |
| Axial mounting-hole centres | 90 |
| Foot overall axial length | 120 |
| Cable-entry diameter | Ø22 |
| Shaft diameter and fit | Ø14 j6 |
| Key width | 5 |
| Shaft keyseat lower-height callout | 11 |
| Shaft-and-key top height | 16 |
| Shaft-end thread and depth | M5 TAP DEEP 7.5 |
| Foot slot detail: length × width | 20 × 10 |
| Shaft extension | 30 |
| Key length callout | 14 |
| Flange bolt pitch-circle diameter | Ø130 |
| Flange pilot diameter and fit | Ø110 h7 |
| Flange outer diameter | Ø160 |
| Flange bolt holes | 4-Ø10 Holes |
| Flange thickness | 10 |
| Flange register projection | 3.5 |
| Overall axial length | 319 |
| Flange face to fan end | 289 |
| Shaft-centre to terminal enclosure outer edge | 114 |
| Shaft-centre to cable-entry axis | 86 |
| Front-view overall vertical envelope | 187 |
| Axial front mounting offset as drawn | 77 |
| Rear foot-hole centre to fan end | 122 |
| Upper axial callout from fan end to drawn reference | 122 |
0.55BV2.pdf
Associated selection rows: 403, 404, 405, 406, 407
PDFdrawings-517.zip > 71 FRAME/B71/0.55BV2.pdf.
Source page 1
Conditions for this section:
- C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| Identity / frame_as_printed | B71 | as printed | — |
| Drawing / Phase | 1 | as printed | C1 |
| Drawing / Construction | Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor | as printed | C1 |
| Drawing note / 1 | Flange mounted IM3001. | as printed | — |
| Drawing note / 2 | TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. | as printed | — |
| Drawing note / 3 | For belt or direct drive. | as printed | — |
Printed rating table — P049, 0.55BV2.pdf, page 1
Conditions for this section:
- C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Configuration / printed row | POLES | kW | HP | SYNCH RPM | Conditions |
|---|---|---|---|---|---|
| 1 | 2 poles | 0.55 kW | 0.75 HP | 3000 rpm (synchronous, as headed) | C1 |
Dimensions read from this original outline
Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.
| Drawing callout | Printed value |
|---|---|
| Cable-entry diameter | Ø22 |
| Shaft diameter and fit | Ø14 j6 |
| Key width | 5 |
| Shaft keyseat lower-height callout | 11 |
| Shaft-and-key top height | 16 |
| Shaft-end thread and depth | M5 TAP DEEP 7.5 |
| Shaft extension | 30 |
| Key length callout | 14 |
| Flange bolt pitch-circle diameter | Ø130 |
| Flange pilot diameter and fit | Ø110 h7 |
| Flange outer diameter | Ø160 |
| Flange bolt holes | 4-Ø10 Holes |
| Flange thickness | 10 |
| Flange register projection | 3.5 |
| Flange-hole angular offset | 45 |
| Overall axial length | 319 |
| Flange face to fan end | 289 |
| Shaft-centre to terminal enclosure outer edge | 114 |
| Shaft-centre to cable-entry axis | 86 |
| Front-view overall vertical envelope | 196 |
Datasheet-510.pdf
The source prints a bearing code in WEIGHT OF MOTOR. This is not a usable mass. The original entry remains below for traceability; catalogue approximate masses are separately labelled.
Associated selection rows: 403
Source page 1
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| MOTOR SERIES | TECO BEGY SINGLE PHASE TEFC | — | |
| START METHOD | DIRECT ONLINE | — | |
| KW RATING | 0.25 | — | |
| VOLTAGE | 240 | (V) | — |
| PHASES | 1 | — | |
| FREQUENCY | 50 | (Hz) | — |
| NO OF POLES | 2 | — | |
| FRAME | D71 | — | |
| SPEED / SYNCHRONOUS | 3000 | (rpm) | — |
| SPEED / FULL LOAD | 2880 | (rpm) | — |
| CURRENT / FULL LOAD | 1.96 | (Amps) | — |
| CURRENT / LOCKED ROTOR | 510 | % | — |
| TORQUE / FULL LOAD TORQUE | 0.78 | (Nm) | — |
| TORQUE / STARTING TORQUE | 260 | % | — |
| TORQUE / MINIMUM TORQUE | Not stated (blank in source) | % | — |
| TORQUE / BREAKDOWN TORQUE | 280 | % | — |
| ROTOR INERTIA (J = GD²/4) | Not stated (blank in source) | (Kgm²) | — |
| EFFICIENCY / 100% LOAD | 65.9 | % | — |
| EFFICIENCY / 75% LOAD | Not stated (blank in source) | % | — |
| EFFICIENCY / 50% LOAD | Not stated (blank in source) | % | — |
| POWER FACTOR / 100% LOAD | 80 | % | — |
| POWER FACTOR / 75% LOAD | Not stated (blank in source) | % | — |
| POWER FACTOR / 50% LOAD | Not stated (blank in source) | % | — |
| INSULATION CLASS | Not stated (blank in source) | — | |
| ENCLOSURE TYPE | TEFC | — | |
| IP RATING | Not stated (blank in source) | — | |
| WEIGHT OF MOTOR | 6202 ZZ | kgs | — |
| BEARINGS / DRIVE END | 6202 ZZ | — | |
| BEARINGS / NON DRIVE END | 6202 ZZ | — | |
| NO LOAD SOUND PRESSURE LEVEL @ 1M | Not stated (blank in source) | dbA | — |
| DESIGN STANDARD | AS1359 | — | |
| CERTIFICATION | Not stated (blank in source) | — | |
| TEMPERATURE RISE ABOVE AMBIENT | Not stated (blank in source) | — |
Datasheet-516.pdf
The source prints a bearing code in WEIGHT OF MOTOR. This is not a usable mass. The original entry remains below for traceability; catalogue approximate masses are separately labelled.
Associated selection rows: 404
Source page 1
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| MOTOR SERIES | TECO BEGY SINGLE PHASE TEFC | — | |
| START METHOD | DIRECT ONLINE | — | |
| KW RATING | 0.25 | — | |
| VOLTAGE | 240 | (V) | — |
| PHASES | 1 | — | |
| FREQUENCY | 50 | (Hz) | — |
| NO OF POLES | 4 | — | |
| FRAME | D71 | — | |
| SPEED / SYNCHRONOUS | 1500 | (rpm) | — |
| SPEED / FULL LOAD | 1420 | (rpm) | — |
| CURRENT / FULL LOAD | 2.12 | (Amps) | — |
| CURRENT / LOCKED ROTOR | 470 | % | — |
| TORQUE / FULL LOAD TORQUE | 1.66 | (Nm) | — |
| TORQUE / STARTING TORQUE | 230 | % | — |
| TORQUE / MINIMUM TORQUE | Not stated (blank in source) | % | — |
| TORQUE / BREAKDOWN TORQUE | 230 | % | — |
| ROTOR INERTIA (J = GD²/4) | Not stated (blank in source) | (Kgm²) | — |
| EFFICIENCY / 100% LOAD | 64.3 | % | — |
| EFFICIENCY / 75% LOAD | Not stated (blank in source) | % | — |
| EFFICIENCY / 50% LOAD | Not stated (blank in source) | % | — |
| POWER FACTOR / 100% LOAD | 75 | % | — |
| POWER FACTOR / 75% LOAD | Not stated (blank in source) | % | — |
| POWER FACTOR / 50% LOAD | Not stated (blank in source) | % | — |
| INSULATION CLASS | Not stated (blank in source) | — | |
| ENCLOSURE TYPE | TEFC | — | |
| IP RATING | Not stated (blank in source) | — | |
| WEIGHT OF MOTOR | 6202 ZZ | kgs | — |
| BEARINGS / DRIVE END | 6202 ZZ | — | |
| BEARINGS / NON DRIVE END | 6202 ZZ | — | |
| NO LOAD SOUND PRESSURE LEVEL @ 1M | Not stated (blank in source) | dbA | — |
| DESIGN STANDARD | AS1359 | — | |
| CERTIFICATION | Not stated (blank in source) | — | |
| TEMPERATURE RISE ABOVE AMBIENT | Not stated (blank in source) | — |
Datasheet-511.pdf
The source prints a bearing code in WEIGHT OF MOTOR. This is not a usable mass. The original entry remains below for traceability; catalogue approximate masses are separately labelled.
Associated selection rows: 405
Source page 1
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| MOTOR SERIES | TECO BEGY SINGLE PHASE TEFC | — | |
| START METHOD | DIRECT ONLINE | — | |
| KW RATING | 0.37 | — | |
| VOLTAGE | 240 | (V) | — |
| PHASES | 1 | — | |
| FREQUENCY | 50 | (Hz) | — |
| NO OF POLES | 2 | — | |
| FRAME | D71 | — | |
| SPEED / SYNCHRONOUS | 3000 | (rpm) | — |
| SPEED / FULL LOAD | 2870 | (rpm) | — |
| CURRENT / FULL LOAD | 2.66 | (Amps) | — |
| CURRENT / LOCKED ROTOR | 490 | % | — |
| TORQUE / FULL LOAD TORQUE | 1.27 | (Nm) | — |
| TORQUE / STARTING TORQUE | 230 | % | — |
| TORQUE / MINIMUM TORQUE | Not stated (blank in source) | % | — |
| TORQUE / BREAKDOWN TORQUE | 230 | % | — |
| ROTOR INERTIA (J = GD²/4) | Not stated (blank in source) | (Kgm²) | — |
| EFFICIENCY / 100% LOAD | 72.4 | % | — |
| EFFICIENCY / 75% LOAD | Not stated (blank in source) | % | — |
| EFFICIENCY / 50% LOAD | Not stated (blank in source) | % | — |
| POWER FACTOR / 100% LOAD | 80 | % | — |
| POWER FACTOR / 75% LOAD | Not stated (blank in source) | % | — |
| POWER FACTOR / 50% LOAD | Not stated (blank in source) | % | — |
| INSULATION CLASS | Not stated (blank in source) | — | |
| ENCLOSURE TYPE | TEFC | — | |
| IP RATING | Not stated (blank in source) | — | |
| WEIGHT OF MOTOR | 6202 ZZ | kgs | — |
| BEARINGS / DRIVE END | 6202 ZZ | — | |
| BEARINGS / NON DRIVE END | 6202 ZZ | — | |
| NO LOAD SOUND PRESSURE LEVEL @ 1M | Not stated (blank in source) | dbA | — |
| DESIGN STANDARD | AS1359 | — | |
| CERTIFICATION | Not stated (blank in source) | — | |
| TEMPERATURE RISE ABOVE AMBIENT | Not stated (blank in source) | — |
Datasheet-517.pdf
The source prints a bearing code in WEIGHT OF MOTOR. This is not a usable mass. The original entry remains below for traceability; catalogue approximate masses are separately labelled.
Associated selection rows: 406
Source page 1
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| MOTOR SERIES | TECO BEGY SINGLE PHASE TEFC | — | |
| START METHOD | DIRECT ONLINE | — | |
| KW RATING | 0.37 | — | |
| VOLTAGE | 240 | (V) | — |
| PHASES | 1 | — | |
| FREQUENCY | 50 | (Hz) | — |
| NO OF POLES | 4 | — | |
| FRAME | D71 | — | |
| SPEED / SYNCHRONOUS | 1500 | (rpm) | — |
| SPEED / FULL LOAD | 1415 | (rpm) | — |
| CURRENT / FULL LOAD | 2.9 | (Amps) | — |
| CURRENT / LOCKED ROTOR | 520 | % | — |
| TORQUE / FULL LOAD TORQUE | 2.45 | (Nm) | — |
| TORQUE / STARTING TORQUE | 220 | % | — |
| TORQUE / MINIMUM TORQUE | Not stated (blank in source) | % | — |
| TORQUE / BREAKDOWN TORQUE | 230 | % | — |
| ROTOR INERTIA (J = GD²/4) | Not stated (blank in source) | (Kgm²) | — |
| EFFICIENCY / 100% LOAD | 68.7 | % | — |
| EFFICIENCY / 75% LOAD | Not stated (blank in source) | % | — |
| EFFICIENCY / 50% LOAD | Not stated (blank in source) | % | — |
| POWER FACTOR / 100% LOAD | 78 | % | — |
| POWER FACTOR / 75% LOAD | Not stated (blank in source) | % | — |
| POWER FACTOR / 50% LOAD | Not stated (blank in source) | % | — |
| INSULATION CLASS | Not stated (blank in source) | — | |
| ENCLOSURE TYPE | TEFC | — | |
| IP RATING | Not stated (blank in source) | — | |
| WEIGHT OF MOTOR | 6202 ZZ | kgs | — |
| BEARINGS / DRIVE END | 6202 ZZ | — | |
| BEARINGS / NON DRIVE END | 6202 ZZ | — | |
| NO LOAD SOUND PRESSURE LEVEL @ 1M | Not stated (blank in source) | dbA | — |
| DESIGN STANDARD | AS1359 | — | |
| CERTIFICATION | Not stated (blank in source) | — | |
| TEMPERATURE RISE ABOVE AMBIENT | Not stated (blank in source) | — |
Datasheet-512.pdf
The source prints a bearing code in WEIGHT OF MOTOR. This is not a usable mass. The original entry remains below for traceability; catalogue approximate masses are separately labelled.
Associated selection rows: 407
Source page 1
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| MOTOR SERIES | TECO BEGY SINGLE PHASE TEFC | — | |
| START METHOD | DIRECT ONLINE | — | |
| KW RATING | 0.55 | — | |
| VOLTAGE | 240 | (V) | — |
| PHASES | 1 | — | |
| FREQUENCY | 50 | (Hz) | — |
| NO OF POLES | 2 | — | |
| FRAME | D71 | — | |
| SPEED / SYNCHRONOUS | 3000 | (rpm) | — |
| SPEED / FULL LOAD | 2865 | (rpm) | — |
| CURRENT / FULL LOAD | 3.74 | (Amps) | — |
| CURRENT / LOCKED ROTOR | 590 | % | — |
| TORQUE / FULL LOAD TORQUE | 1.86 | (Nm) | — |
| TORQUE / STARTING TORQUE | 270 | % | — |
| TORQUE / MINIMUM TORQUE | Not stated (blank in source) | % | — |
| TORQUE / BREAKDOWN TORQUE | 240 | % | — |
| ROTOR INERTIA (J = GD²/4) | Not stated (blank in source) | (Kgm²) | — |
| EFFICIENCY / 100% LOAD | 73 | % | — |
| EFFICIENCY / 75% LOAD | Not stated (blank in source) | % | — |
| EFFICIENCY / 50% LOAD | Not stated (blank in source) | % | — |
| POWER FACTOR / 100% LOAD | 86 | % | — |
| POWER FACTOR / 75% LOAD | Not stated (blank in source) | % | — |
| POWER FACTOR / 50% LOAD | Not stated (blank in source) | % | — |
| INSULATION CLASS | Not stated (blank in source) | — | |
| ENCLOSURE TYPE | TEFC | — | |
| IP RATING | Not stated (blank in source) | — | |
| WEIGHT OF MOTOR | 6202 ZZ | kgs | — |
| BEARINGS / DRIVE END | 6202 ZZ | — | |
| BEARINGS / NON DRIVE END | 6202 ZZ | — | |
| NO LOAD SOUND PRESSURE LEVEL @ 1M | Not stated (blank in source) | dbA | — |
| DESIGN STANDARD | AS1359 | — | |
| CERTIFICATION | Not stated (blank in source) | — | |
| TEMPERATURE RISE ABOVE AMBIENT | Not stated (blank in source) | — |
0.75BE2 , 0.55BE4 , 0.75BE4.pdf
Associated selection rows: 408, 409, 410, 411
PDFdrawings-519.zip > 80 FRAME/0.75BE2 , 0.55BE4 , 0.75BE4.pdf.
Source page 1
Conditions for this section:
- C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| Identity / frame_as_printed | D80 | as printed | — |
| Drawing / Phase | 1 | as printed | C1 |
| Drawing / Construction | Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor | as printed | C1 |
| Drawing note / 1 | Foot mounted IM1001. | as printed | — |
| Drawing note / 2 | TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. | as printed | — |
| Drawing note / 3 | For belt or direct drive. | as printed | — |
Printed rating table — P049, 0.75BE2 , 0.55BE4 , 0.75BE4.pdf, page 1
Conditions for this section:
- C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Configuration / printed row | POLES | kW | HP | SYNCH RPM | Conditions |
|---|---|---|---|---|---|
| 1 | 2 poles | 0.75 kW | 1 HP | 3000 rpm (synchronous, as headed) | C1 |
| 2 | 4 poles | 0.55/0.75 kW | 0.75/1 HP | 1500 rpm (synchronous, as headed) | C1 |
Dimensions read from this original outline
Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.
| Drawing callout | Printed value |
|---|---|
| Transverse mounting-hole centres | 125 |
| Foot overall width | 165 |
| Foot slot-group width callout | 40 |
| Foot thickness | 3.2 |
| Shaft height and tolerance | 80 +0/−0.5 |
| Lower terminal enclosure height above foot plane | 40 |
| Axial mounting-hole centres | 100 |
| Foot overall axial length | 130 |
| Cable-entry diameter | Ø22 |
| Shaft diameter and fit | Ø19 j6 |
| Key width | 6 |
| Shaft keyseat lower-height callout | 15.5 |
| Shaft-and-key top height | 21.5 |
| Shaft-end thread and depth | M6 TAP DEEP 9 |
| Foot slot detail: length × width | 20 × 10 |
| Shaft extension | 40 |
| Key length callout | 25 |
| Overall axial length | 307 |
| Shaft-centre to terminal enclosure outer edge | 122 |
| Shaft-centre to cable-entry axis | 94 |
| Front-view body width callout | 163 |
| Front-view overall vertical envelope | 205 |
| Shaft shoulder to nearer foot-hole centre | 50 |
| Rear foot-hole centre to fan end | 117 |
| Upper axial callout from fan end to drawn reference | 123 |
0.75BF2 , 0.55BF4.pdf
Associated selection rows: 408, 409, 410, 411
PDFdrawings-519.zip > 80 FRAME/0.75BF2 , 0.55BF4.pdf.
Source page 1
Conditions for this section:
- C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| Identity / frame_as_printed | D80 | as printed | — |
| Drawing / Phase | 1 | as printed | C1 |
| Drawing / Construction | Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor | as printed | C1 |
| Drawing note / 1 | Foot & flange mounted IM2001. | as printed | — |
| Drawing note / 2 | TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. | as printed | — |
| Drawing note / 3 | For belt or direct drive. | as printed | — |
Printed rating table — P049, 0.75BF2 , 0.55BF4.pdf, page 1
Conditions for this section:
- C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Configuration / printed row | POLES | kW | HP | SYNCH RPM | Conditions |
|---|---|---|---|---|---|
| 1 | 2 poles | 0.75 kW | 1 HP | 3000 rpm (synchronous, as headed) | C1 |
| 2 | 4 poles | 0.55 kW | 0.75 HP | 1500 rpm (synchronous, as headed) | C1 |
TECO Single Phase Steel Frame – BEGY — technical configurations, part 2 of 2
Product: P049. Product page: https://electricmotors.teco.com.au/product/teco-single-phase-steel-frame-motors/
Dimensions read from this original outline
Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.
| Drawing callout | Printed value |
|---|---|
| Transverse mounting-hole centres | 125 |
| Foot overall width | 165 |
| Foot slot-group width callout | 40 |
| Foot thickness | 3.2 |
| Shaft height and tolerance | 80 +0/−0.5 |
| Lower terminal enclosure height above foot plane | 40 |
| Axial mounting-hole centres | 100 |
| Foot overall axial length | 130 |
| Cable-entry diameter | Ø22 |
| Shaft diameter and fit | Ø19 j6 |
| Key width | 6 |
| Shaft keyseat lower-height callout | 15.5 |
| Shaft-and-key top height | 21.5 |
| Shaft-end thread and depth | M6 TAP DEEP 9 |
| Foot slot detail: length × width | 20 × 10 |
| Shaft extension | 40 |
| Key length callout | 25 |
| Flange bolt pitch-circle diameter | Ø165 |
| Flange pilot diameter and fit | Ø130 h7 |
| Flange outer diameter | Ø200 |
| Flange bolt holes | 4-Ø12 Holes |
| Flange thickness | 12 |
| Flange register projection | 3.5 |
| Overall axial length | 335 |
| Shaft-centre to terminal enclosure outer edge | 122 |
| Shaft-centre to cable-entry axis | 94 |
| Front-view overall vertical envelope | 205 |
| Axial front mounting offset as drawn | 77.5 |
| Rear foot-hole centre to fan end | 148 |
| Upper axial callout from fan end to drawn reference | 123 |
| Axial foot slot-group callout | 30 |
0.75BF4.pdf
Associated selection rows: 408, 409, 410, 411
PDFdrawings-519.zip > 80 FRAME/0.75BF4.pdf.
Source page 1
Conditions for this section:
- C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| Identity / frame_as_printed | D80 | as printed | — |
| Drawing / Phase | 1 | as printed | C1 |
| Drawing / Construction | Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor | as printed | C1 |
| Drawing note / 1 | Foot & flange mounted IM2001. | as printed | — |
| Drawing note / 2 | TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. | as printed | — |
| Drawing note / 3 | For belt or direct drive. | as printed | — |
Printed rating table — P049, 0.75BF4.pdf, page 1
Conditions for this section:
- C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Configuration / printed row | POLES | kW | HP | SYNCH RPM | Conditions |
|---|---|---|---|---|---|
| 1 | 4 poles | 0.75 kW | 1 HP | 1500 rpm (synchronous, as headed) | C1 |
Dimensions read from this original outline
Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.
| Drawing callout | Printed value |
|---|---|
| Transverse mounting-hole centres | 125 |
| Foot overall width | 165 |
| Foot slot-group width callout | 40 |
| Foot thickness | 3.2 |
| Shaft height and tolerance | 80 +0/−0.5 |
| Lower terminal enclosure height above foot plane | 40 |
| Axial mounting-hole centres | 100 |
| Foot overall axial length | 130 |
| Cable-entry diameter | Ø22 |
| Shaft diameter and fit | Ø19 j6 |
| Key width | 6 |
| Shaft keyseat lower-height callout | 15.5 |
| Shaft-and-key top height | 21.5 |
| Shaft-end thread and depth | M6 TAP DEEP 9 |
| Foot slot detail: length × width | 20 × 10 |
| Shaft extension | 40 |
| Key length callout | 25 |
| Flange bolt pitch-circle diameter | Ø165 |
| Flange pilot diameter and fit | Ø130 h7 |
| Flange outer diameter | Ø200 |
| Flange bolt holes | 4-Ø12 Holes |
| Flange thickness | 12 |
| Flange register projection | 3.5 |
| Overall axial length | 355 |
| Shaft-centre to terminal enclosure outer edge | 122 |
| Shaft-centre to cable-entry axis | 94 |
| Front-view overall vertical envelope | 205 |
| Axial front mounting offset as drawn | 77.5 |
| Rear foot-hole centre to fan end | 138 |
| Upper axial callout from fan end to drawn reference | 143 |
| Axial foot slot-group callout | 30 |
0.75BV4.pdf
Associated selection rows: 408, 409, 410, 411
PDFdrawings-519.zip > 80 FRAME/0.75BV4.pdf.
Source page 1
Conditions for this section:
- C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| Identity / frame_as_printed | D80 | as printed | — |
| Drawing / Phase | 1 | as printed | C1 |
| Drawing / Construction | Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor | as printed | C1 |
| Drawing note / 1 | Flange mounted IM3001. | as printed | — |
| Drawing note / 2 | TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. | as printed | — |
| Drawing note / 3 | For belt or direct drive. | as printed | — |
Printed rating table — P049, 0.75BV4.pdf, page 1
Conditions for this section:
- C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Configuration / printed row | POLES | kW | HP | SYNCH RPM | Conditions |
|---|---|---|---|---|---|
| 1 | 4 poles | 0.75 kW | 1 HP | 1500 rpm (synchronous, as headed) | C1 |
Dimensions read from this original outline
Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.
| Drawing callout | Printed value |
|---|---|
| Cable-entry diameter | Ø22 |
| Shaft diameter and fit | Ø19 j6 |
| Key width | 6 |
| Shaft keyseat lower-height callout | 15.5 |
| Shaft-and-key top height | 21.5 |
| Shaft-end thread and depth | M6 TAP DEEP 9 |
| Shaft extension | 40 |
| Key length callout | 25 |
| Flange bolt pitch-circle diameter | Ø165 |
| Flange pilot diameter and fit | Ø130 h7 |
| Flange outer diameter | Ø200 |
| Flange bolt holes | 4-Ø12 Holes |
| Flange thickness | 12 |
| Flange register projection | 3 |
| Flange-hole angular offset | 45 |
| Overall axial length | 335 |
| Flange face to fan end | 295 |
| Shaft-centre to terminal enclosure outer edge | 122 |
| Shaft-centre to cable-entry axis | 94 |
| Front-view overall vertical envelope | 225 |
0.75VB2 , 0.55BV4.pdf
Associated selection rows: 408, 409, 410, 411
PDFdrawings-519.zip > 80 FRAME/0.75VB2 , 0.55BV4.pdf.
Source page 1
Conditions for this section:
- C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| Identity / frame_as_printed | D80 | as printed | — |
| Drawing / Phase | 1 | as printed | C1 |
| Drawing / Construction | Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor | as printed | C1 |
| Drawing note / 1 | Flange mounted IM3001. | as printed | — |
| Drawing note / 2 | TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. | as printed | — |
| Drawing note / 3 | For belt or direct drive. | as printed | — |
Printed rating table — P049, 0.75VB2 , 0.55BV4.pdf, page 1
Conditions for this section:
- C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Configuration / printed row | POLES | kW | HP | SYNCH RPM | Conditions |
|---|---|---|---|---|---|
| 1 | 2 poles | 0.75 kW | 1 HP | 3000 rpm (synchronous, as headed) | C1 |
| 2 | 4 poles | 0.55 kW | 0.75 HP | 1500 rpm (synchronous, as headed) | C1 |
Dimensions read from this original outline
Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.
| Drawing callout | Printed value |
|---|---|
| Cable-entry diameter | Ø22 |
| Shaft diameter and fit | Ø19 j6 |
| Key width | 6 |
| Shaft keyseat lower-height callout | 15.5 |
| Shaft-and-key top height | 21.5 |
| Shaft-end thread and depth | M6 TAP DEEP 9 |
| Shaft extension | 40 |
| Key length callout | 25 |
| Flange bolt pitch-circle diameter | Ø165 |
| Flange pilot diameter and fit | Ø130 h7 |
| Flange outer diameter | Ø200 |
| Flange bolt holes | 4-Ø12 Holes |
| Flange thickness | 12 |
| Flange register projection | 3 |
| Flange-hole angular offset | 45 |
| Overall axial length | 325 |
| Flange face to fan end | 285 |
| Shaft-centre to terminal enclosure outer edge | 122 |
| Shaft-centre to cable-entry axis | 94 |
| Front-view overall vertical envelope | 225 |
1.1BE2.pdf
Associated selection rows: 408, 409, 410, 411
PDFdrawings-519.zip > 80 FRAME/1.1BE2.pdf.
Source page 1
Conditions for this section:
- C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| Identity / frame_as_printed | D80 | as printed | — |
| Drawing / Phase | 1 | as printed | C1 |
| Drawing / Construction | Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor | as printed | C1 |
| Drawing note / 1 | Foot mounted IM1001. | as printed | — |
| Drawing note / 2 | TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. | as printed | — |
| Drawing note / 3 | For belt or direct drive. | as printed | — |
Printed rating table — P049, 1.1BE2.pdf, page 1
Conditions for this section:
- C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Configuration / printed row | POLES | kW | HP | SYNCH RPM | Conditions |
|---|---|---|---|---|---|
| 1 | 2 poles | 1.1 kW | 1.5 HP | 3000 rpm (synchronous, as headed) | C1 |
Dimensions read from this original outline
Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.
| Drawing callout | Printed value |
|---|---|
| Transverse mounting-hole centres | 125 |
| Foot overall width | 165 |
| Foot slot-group width callout | 40 |
| Foot thickness | 3.2 |
| Shaft height and tolerance | 80 +0/−0.5 |
| Lower terminal enclosure height above foot plane | 40 |
| Axial mounting-hole centres | 100 |
| Foot overall axial length | 130 |
| Cable-entry diameter | Ø22 |
| Shaft diameter and fit | Ø19 j6 |
| Key width | 6 |
| Shaft keyseat lower-height callout | 15.5 |
| Shaft-and-key top height | 21.5 |
| Shaft-end thread and depth | M6 TAP DEEP 9 |
| Foot slot detail: length × width | 20 × 10 |
| Shaft extension | 40 |
| Key length callout | 25 |
| Overall axial length | 307 |
| Shaft-centre to terminal enclosure outer edge | 122 |
| Shaft-centre to cable-entry axis | 94 |
| Front-view body width callout | 163 |
| Front-view overall vertical envelope | 211 |
| Shaft shoulder to nearer foot-hole centre | 50 |
| Rear foot-hole centre to fan end | 117 |
| Upper axial callout from fan end to drawn reference | 123 |
1.1BF2.pdf
Associated selection rows: 408, 409, 410, 411
PDFdrawings-519.zip > 80 FRAME/1.1BF2.pdf.
Source page 1
Conditions for this section:
- C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| Identity / frame_as_printed | D80 | as printed | — |
| Drawing / Phase | 1 | as printed | C1 |
| Drawing / Construction | Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor | as printed | C1 |
| Drawing note / 1 | Foot & flange mounted IM2001. | as printed | — |
| Drawing note / 2 | TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. | as printed | — |
| Drawing note / 3 | For belt or direct drive. | as printed | — |
Printed rating table — P049, 1.1BF2.pdf, page 1
Conditions for this section:
- C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Configuration / printed row | POLES | kW | HP | SYNCH RPM | Conditions |
|---|---|---|---|---|---|
| 1 | 2 poles | 1.1 kW | 1.5 HP | 3000 rpm (synchronous, as headed) | C1 |
Dimensions read from this original outline
Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.
| Drawing callout | Printed value |
|---|---|
| Transverse mounting-hole centres | 125 |
| Foot overall width | 165 |
| Foot slot-group width callout | 40 |
| Foot thickness | 3.2 |
| Shaft height and tolerance | 80 +0/−0.5 |
| Lower terminal enclosure height above foot plane | 40 |
| Axial mounting-hole centres | 100 |
| Foot overall axial length | 130 |
| Cable-entry diameter | Ø22 |
| Shaft diameter and fit | Ø19 j6 |
| Key width | 6 |
| Shaft keyseat lower-height callout | 15.5 |
| Shaft-and-key top height | 21.5 |
| Shaft-end thread and depth | M6 TAP DEEP 9 |
| Foot slot detail: length × width | 20 × 10 |
| Shaft extension | 40 |
| Key length callout | 25 |
| Flange bolt pitch-circle diameter | Ø165 |
| Flange pilot diameter and fit | Ø130 h7 |
| Flange outer diameter | Ø200 |
| Flange bolt holes | 4-Ø12 Holes |
| Flange thickness | 12 |
| Flange register projection | 3.5 |
| Overall axial length | 355 |
| Shaft-centre to terminal enclosure outer edge | 122 |
| Shaft-centre to cable-entry axis | 94 |
| Front-view overall vertical envelope | 211 |
| Axial front mounting offset as drawn | 77.5 |
| Rear foot-hole centre to fan end | 138 |
| Upper axial callout from fan end to drawn reference | 143 |
| Axial foot slot-group callout | 30 |
1.1BV2.pdf
Associated selection rows: 408, 409, 410, 411
PDFdrawings-519.zip > 80 FRAME/1.1BV2.pdf.
Source page 1
Conditions for this section:
- C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| Identity / frame_as_printed | D80 | as printed | — |
| Drawing / Phase | 1 | as printed | C1 |
| Drawing / Construction | Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor | as printed | C1 |
| Drawing note / 1 | Flange mounted IM3001. | as printed | — |
| Drawing note / 2 | TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. | as printed | — |
| Drawing note / 3 | For belt or direct drive. | as printed | — |
Printed rating table — P049, 1.1BV2.pdf, page 1
Conditions for this section:
- C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
| Configuration / printed row | POLES | kW | HP | SYNCH RPM | Conditions |
|---|---|---|---|---|---|
| 1 | 2 poles | 1.1 kW | 1.5 HP | 3000 rpm (synchronous, as headed) | C1 |
Dimensions read from this original outline
Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.
| Drawing callout | Printed value |
|---|---|
| Cable-entry diameter | Ø22 |
| Shaft diameter and fit | Ø19 j6 |
| Key width | 6 |
| Shaft keyseat lower-height callout | 15.5 |
| Shaft-and-key top height | 21.5 |
| Shaft-end thread and depth | M6 TAP DEEP 9 |
| Shaft extension | 40 |
| Key length callout | 25 |
| Flange bolt pitch-circle diameter | Ø165 |
| Flange pilot diameter and fit | Ø130 h7 |
| Flange outer diameter | Ø200 |
| Flange bolt holes | 4-Ø12 Holes |
| Flange thickness | 12 |
| Flange register projection | 3 |
| Flange-hole angular offset | 45 |
| Overall axial length | 335 |
| Flange face to fan end | 295 |
| Shaft-centre to terminal enclosure outer edge | 122 |
| Shaft-centre to cable-entry axis | 94 |
| Front-view overall vertical envelope | 231 |
Datasheet-518.pdf
The source prints a bearing code in WEIGHT OF MOTOR. This is not a usable mass. The original entry remains below for traceability; catalogue approximate masses are separately labelled.
Associated selection rows: 408
Source page 1
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| MOTOR SERIES | TECO BEGY SINGLE PHASE TEFC | — | |
| START METHOD | DIRECT ONLINE | — | |
| KW RATING | 0.55 | — | |
| VOLTAGE | 240 | (V) | — |
| PHASES | 1 | — | |
| FREQUENCY | 50 | (Hz) | — |
| NO OF POLES | 4 | — | |
| FRAME | D80 | — | |
| SPEED / SYNCHRONOUS | 1500 | (rpm) | — |
| SPEED / FULL LOAD | 1425 | (rpm) | — |
| CURRENT / FULL LOAD | 4.3 | (Amps) | — |
| CURRENT / LOCKED ROTOR | 510 | % | — |
| TORQUE / FULL LOAD TORQUE | 3.7 | (Nm) | — |
| TORQUE / STARTING TORQUE | 260 | % | — |
| TORQUE / MINIMUM TORQUE | Not stated (blank in source) | % | — |
| TORQUE / BREAKDOWN TORQUE | 180 | % | — |
| ROTOR INERTIA (J = GD²/4) | Not stated (blank in source) | (Kgm²) | — |
| EFFICIENCY / 100% LOAD | 70.1 | % | — |
| EFFICIENCY / 75% LOAD | Not stated (blank in source) | % | — |
| EFFICIENCY / 50% LOAD | Not stated (blank in source) | % | — |
| POWER FACTOR / 100% LOAD | 77 | % | — |
| POWER FACTOR / 75% LOAD | Not stated (blank in source) | % | — |
| POWER FACTOR / 50% LOAD | Not stated (blank in source) | % | — |
| INSULATION CLASS | Not stated (blank in source) | — | |
| ENCLOSURE TYPE | TEFC | — | |
| IP RATING | Not stated (blank in source) | — | |
| WEIGHT OF MOTOR | 6204 ZZ | kgs | — |
| BEARINGS / DRIVE END | 6204 ZZ | — | |
| BEARINGS / NON DRIVE END | 6202 ZZ | — | |
| NO LOAD SOUND PRESSURE LEVEL @ 1M | Not stated (blank in source) | dbA | — |
| DESIGN STANDARD | AS1359 | — | |
| CERTIFICATION | Not stated (blank in source) | — | |
| TEMPERATURE RISE ABOVE AMBIENT | Not stated (blank in source) | — |
Datasheet-513.pdf
The source prints a bearing code in WEIGHT OF MOTOR. This is not a usable mass. The original entry remains below for traceability; catalogue approximate masses are separately labelled.
Associated selection rows: 409
Source page 1
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| MOTOR SERIES | TECO BEGY SINGLE PHASE TEFC | — | |
| START METHOD | DIRECT ONLINE | — | |
| KW RATING | 0.75 | — | |
| VOLTAGE | 240 | (V) | — |
| PHASES | 1 | — | |
| FREQUENCY | 50 | (Hz) | — |
| NO OF POLES | 2 | — | |
| FRAME | D80 | — | |
| SPEED / SYNCHRONOUS | 3000 | (rpm) | — |
| SPEED / FULL LOAD | 2900 | (rpm) | — |
| CURRENT / FULL LOAD | 4.84 | (Amps) | — |
| CURRENT / LOCKED ROTOR | 700 | % | — |
| TORQUE / FULL LOAD TORQUE | 2.45 | (Nm) | — |
| TORQUE / STARTING TORQUE | 320 | % | — |
| TORQUE / MINIMUM TORQUE | Not stated (blank in source) | % | — |
| TORQUE / BREAKDOWN TORQUE | 280 | % | — |
| ROTOR INERTIA (J = GD²/4) | Not stated (blank in source) | (Kgm²) | — |
| EFFICIENCY / 100% LOAD | 74 | % | — |
| EFFICIENCY / 75% LOAD | Not stated (blank in source) | % | — |
| EFFICIENCY / 50% LOAD | Not stated (blank in source) | % | — |
| POWER FACTOR / 100% LOAD | 87 | % | — |
| POWER FACTOR / 75% LOAD | Not stated (blank in source) | % | — |
| POWER FACTOR / 50% LOAD | Not stated (blank in source) | % | — |
| INSULATION CLASS | Not stated (blank in source) | — | |
| ENCLOSURE TYPE | TEFC | — | |
| IP RATING | Not stated (blank in source) | — | |
| WEIGHT OF MOTOR | 6204 ZZ | kgs | — |
| BEARINGS / DRIVE END | 6204 ZZ | — | |
| BEARINGS / NON DRIVE END | 6202 ZZ | — | |
| NO LOAD SOUND PRESSURE LEVEL @ 1M | Not stated (blank in source) | dbA | — |
| DESIGN STANDARD | AS1359 | — | |
| CERTIFICATION | Not stated (blank in source) | — | |
| TEMPERATURE RISE ABOVE AMBIENT | Not stated (blank in source) | — |
Datasheet-519.pdf
The source prints a bearing code in WEIGHT OF MOTOR. This is not a usable mass. The original entry remains below for traceability; catalogue approximate masses are separately labelled.
Associated selection rows: 410
Source page 1
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| MOTOR SERIES | TECO BEGY SINGLE PHASE TEFC | — | |
| START METHOD | DIRECT ONLINE | — | |
| KW RATING | 0.75 | — | |
| VOLTAGE | 240 | (V) | — |
| PHASES | 1 | — | |
| FREQUENCY | 50 | (Hz) | — |
| NO OF POLES | 4 | — | |
| FRAME | D80 | — | |
| SPEED / SYNCHRONOUS | 1500 | (rpm) | — |
| SPEED / FULL LOAD | 1425 | (rpm) | — |
| CURRENT / FULL LOAD | 5 | (Amps) | — |
| CURRENT / LOCKED ROTOR | 580 | % | — |
| TORQUE / FULL LOAD TORQUE | 5 | (Nm) | — |
| TORQUE / STARTING TORQUE | 250 | % | — |
| TORQUE / MINIMUM TORQUE | Not stated (blank in source) | % | — |
| TORQUE / BREAKDOWN TORQUE | 220 | % | — |
| ROTOR INERTIA (J = GD²/4) | Not stated (blank in source) | (Kgm²) | — |
| EFFICIENCY / 100% LOAD | 72.1 | % | — |
| EFFICIENCY / 75% LOAD | Not stated (blank in source) | % | — |
| EFFICIENCY / 50% LOAD | Not stated (blank in source) | % | — |
| POWER FACTOR / 100% LOAD | 86 | % | — |
| POWER FACTOR / 75% LOAD | Not stated (blank in source) | % | — |
| POWER FACTOR / 50% LOAD | Not stated (blank in source) | % | — |
| INSULATION CLASS | Not stated (blank in source) | — | |
| ENCLOSURE TYPE | TEFC | — | |
| IP RATING | Not stated (blank in source) | — | |
| WEIGHT OF MOTOR | 6204 ZZ | kgs | — |
| BEARINGS / DRIVE END | 6204 ZZ | — | |
| BEARINGS / NON DRIVE END | 6202 ZZ | — | |
| NO LOAD SOUND PRESSURE LEVEL @ 1M | Not stated (blank in source) | dbA | — |
| DESIGN STANDARD | AS1359 | — | |
| CERTIFICATION | Not stated (blank in source) | — | |
| TEMPERATURE RISE ABOVE AMBIENT | Not stated (blank in source) | — |
Datasheet-514.pdf
The source prints a bearing code in WEIGHT OF MOTOR. This is not a usable mass. The original entry remains below for traceability; catalogue approximate masses are separately labelled.
Associated selection rows: 411
Source page 1
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| MOTOR SERIES | TECO BEGY SINGLE PHASE TEFC | — | |
| START METHOD | DIRECT ONLINE | — | |
| KW RATING | 1.1 | — | |
| VOLTAGE | 240 | (V) | — |
| PHASES | 1 | — | |
| FREQUENCY | 50 | (Hz) | — |
| NO OF POLES | 2 | — | |
| FRAME | D80 | — | |
| SPEED / SYNCHRONOUS | 3000 | (rpm) | — |
| SPEED / FULL LOAD | 2880 | (rpm) | — |
| CURRENT / FULL LOAD | 6.6 | (Amps) | — |
| CURRENT / LOCKED ROTOR | 650 | % | — |
| TORQUE / FULL LOAD TORQUE | 3.6 | (Nm) | — |
| TORQUE / STARTING TORQUE | 240 | % | — |
| TORQUE / MINIMUM TORQUE | Not stated (blank in source) | % | — |
| TORQUE / BREAKDOWN TORQUE | 250 | % | — |
| ROTOR INERTIA (J = GD²/4) | Not stated (blank in source) | (Kgm²) | — |
| EFFICIENCY / 100% LOAD | 75.5 | % | — |
| EFFICIENCY / 75% LOAD | Not stated (blank in source) | % | — |
| EFFICIENCY / 50% LOAD | Not stated (blank in source) | % | — |
| POWER FACTOR / 100% LOAD | 94 | % | — |
| POWER FACTOR / 75% LOAD | Not stated (blank in source) | % | — |
| POWER FACTOR / 50% LOAD | Not stated (blank in source) | % | — |
| INSULATION CLASS | Not stated (blank in source) | — | |
| ENCLOSURE TYPE | TEFC | — | |
| IP RATING | Not stated (blank in source) | — | |
| WEIGHT OF MOTOR | 6204 ZZ | kgs | — |
| BEARINGS / DRIVE END | 6204 ZZ | — | |
| BEARINGS / NON DRIVE END | 6202 ZZ | — | |
| NO LOAD SOUND PRESSURE LEVEL @ 1M | Not stated (blank in source) | dbA | — |
| DESIGN STANDARD | AS1359 | — | |
| CERTIFICATION | Not stated (blank in source) | — | |
| TEMPERATURE RISE ABOVE AMBIENT | Not stated (blank in source) | — |
Datasheet-515.pdf
Associated selection rows: 412
Source differences and limitations
- Website/source difference — FRAME: website D63; PDF page 1 D71. Website row IDs: 412. Neither is automatically substituted for the other.
Source page 1
| Specification | Value | Unit / basis | Conditions |
|---|---|---|---|
| MOTOR SERIES | TECO BEGY SINGLE PHASE TEFC | — | |
| START METHOD | DIRECT ONLINE | — | |
| KW RATING | 0.18 | — | |
| VOLTAGE | 240 | (V) | — |
| PHASES | 1 | — | |
| FREQUENCY | 50 | (Hz) | — |
| NO OF POLES | 4 | — | |
| FRAME | D71 | — | |
| SPEED / SYNCHRONOUS | 1500 | (rpm) | — |
| SPEED / FULL LOAD | 1430 | (rpm) | — |
| CURRENT / FULL LOAD | 1.7 | (Amps) | — |
| CURRENT / LOCKED ROTOR | 470 | % | — |
| TORQUE / FULL LOAD TORQUE | 1.18 | (Nm) | — |
| TORQUE / STARTING TORQUE | 270 | % | — |
| TORQUE / MINIMUM TORQUE | Not stated (blank in source) | % | — |
| TORQUE / BREAKDOWN TORQUE | 240 | % | — |
| ROTOR INERTIA (J = GD²/4) | Not stated (blank in source) | (Kgm²) | — |
| EFFICIENCY / 100% LOAD | 63.5 | % | — |
| EFFICIENCY / 75% LOAD | Not stated (blank in source) | % | — |
| EFFICIENCY / 50% LOAD | Not stated (blank in source) | % | — |
| POWER FACTOR / 100% LOAD | 72 | % | — |
| POWER FACTOR / 75% LOAD | Not stated (blank in source) | % | — |
| POWER FACTOR / 50% LOAD | Not stated (blank in source) | % | — |
| INSULATION CLASS | Not stated (blank in source) | — | |
| ENCLOSURE TYPE | TEFC | — | |
| IP RATING | Not stated (blank in source) | — | |
| WEIGHT OF MOTOR | 7.5 | kgs | — |
| BEARINGS / DRIVE END | 6201ZZ | — | |
| BEARINGS / NON DRIVE END | 6201 ZZ | — | |
| NO LOAD SOUND PRESSURE LEVEL @ 1M | Not stated (blank in source) | dbA | — |
| DESIGN STANDARD | AS1359 | — | |
| CERTIFICATION | Not stated (blank in source) | — | |
| TEMPERATURE RISE ABOVE AMBIENT | Not stated (blank in source) | — |
Downloads, customisation and support
Download our single-phase catalogue. Individual datasheets, PDF archives and CAD downloads are linked with the selections above. We can help with mounting options, terminal-box arrangements, 3D files and certified dimensions.
No separate operating manual is attached in the collected BEGY product pack. Contact our team for the installation instructions and modifications relevant to your motor. Historical catalogue contact details are replaced here by our current contact-page link.
Company documents
- TAC-EMD-Standard-Conditions-of-Sale-Final-May-2022.pdf
- ISO9001-Intertek-SAI-Global-Certificate-QEC3088-Expiry-25-May-2029.pdf
- ISO45001-Intertek-SAI-Global-Certificate-0185118-Expiry-22-August-2027.pdf
These company references have their own scope; they are not motor-specific approvals.
Source editions: TECO1PH-032014 catalogue and individual configuration sheets collected 15 October 2026. Product-page wording checked 27 October 2026. Source differences and original document identities remain traceable.