Practical single-phase power in a compact steel-frame package. Our BEGY motors use capacitor start–capacitor run (CSR) operation for high starting torque and good running performance, with a choice of foot, flange, or foot-and-flange mounting. Tell us about your application and we'll help you select the right configuration.

Our catalogue and listed selections cover 0.25–1.1 kW at two poles and 0.18–0.75 kW at four poles. The individual datasheets specify 240 V, single-phase, 50 Hz, direct-on-line starting and totally enclosed fan cooling. Our steel-frame product description specifies Class F insulation, S1 continuous duty, IP44 protection, IC411 cooling and manual overload protection, with a one-year warranty. Confirm the warranty terms and fitted protection for your purchase with us.

Before ordering: our website's headline range and some feature text differ from its selection table and attachments. The 0.18 kW four-pole entry also has conflicting frame and bearing details. We retain those differences below so you can confirm the exact motor with our team.

Choose your BEGY configuration

Our 10 listed selections are linked to their individual datasheets and the collected drawing sets. Each distinct PDF appears once in the detailed reference below. A shared archive includes several ratings and mountings; match the power, pole count, frame and mounting on the drawing before using its dimensions. An archive association alone does not prove that every member applies to every selection.

The drawings include IM1001 foot, IM2001 foot and flange, and IM3001 flange arrangements. Our catalogue calls the flange-only steel-frame series BETY; its designation remains unchanged in those tables.

RowWebsite specificationDatasheetDrawings / archive members
403kW Rating: 0.25; Voltage: 240; Phases: 1; No. of Poles: 2; Frame Size: D71Datasheet-510.pdf13 drawings in shared set
404kW Rating: 0.25; Voltage: 240; Phases: 1; No. of Poles: 4; Frame Size: D71Datasheet-516.pdf13 drawings in shared set
405kW Rating: 0.37; Voltage: 240; Phases: 1; No. of Poles: 2; Frame Size: D71Datasheet-511.pdf13 drawings in shared set
406kW Rating: 0.37; Voltage: 240; Phases: 1; No. of Poles: 4; Frame Size: D71Datasheet-517.pdf13 drawings in shared set
407kW Rating: 0.55; Voltage: 240; Phases: 1; No. of Poles: 2; Frame Size: D71Datasheet-512.pdf13 drawings in shared set
408kW Rating: 0.55; Voltage: 240; Phases: 1; No. of Poles: 4; Frame Size: D80Datasheet-518.pdf8 drawings in shared set
409kW Rating: 0.75; Voltage: 240; Phases: 1; No. of Poles: 2; Frame Size: D80Datasheet-513.pdf8 drawings in shared set
410kW Rating: 0.75; Voltage: 240; Phases: 1; No. of Poles: 4; Frame Size: D80Datasheet-519.pdf8 drawings in shared set
411kW Rating: 1.10; Voltage: 240; Phases: 1; No. of Poles: 2; Frame Size: D80Datasheet-514.pdf8 drawings in shared set
412kW Rating: 0.18; Voltage: 240; Phases: 1; No. of Poles: 4; Frame Size: D63Datasheet-515.pdfAvailable upon request

Shared drawing set 1

Original archive membership; choose the matching rating and mounting.

Shared drawing set 2

Original archive membership; choose the matching rating and mounting.

CAD downloads: CADdrawings-517.zip · CADdrawings-519.zip

All 10 3D-drawing fields are available upon request. The 0.18 kW four-pole row also lists its PDF and CAD drawings as available upon request. Drawings naming 0.18 kW exist in other rows' shared archives, but we have not reassigned them to this row or treated them as a confirmed D63 outline. No software download is listed.

Built around your application

Start with your available supply, starting and running torque, operating duty, and mounting space. Our CSR motors use a start capacitor for starting torque and a run capacitor during operation. Exact speed, current, efficiency, torque, power factor and capacitor values are specific to each rating and remain in the tables below.

Our catalogue describes continuous operation at nameplate current, an ambient range of −10 to 40°C, and operation below 1,000 m altitude. Above those conditions, contact us about derating. Its standard specification lists non-hazardous environments, maximum 90% relative humidity, and belt or direct drive. Historical IEC34 and AS1359/1360 references remain with the catalogue; our website names IEC60034 and AS1359. These references are not a current certificate of approval.

For the catalogue's 71–80 frames, construction includes a rolled-steel frame, aluminium-alloy endshields with steel inserts, and a cast-iron drive-end endshield on frame 80. A bidirectional polypropylene fan, pressed-steel fan cover and terminal box, double-shielded pre-greased bearings, copper random-wound stator and dynamically balanced die-cast aluminium rotor complete the assembly. The catalogue describes Class F insulation and a centrifugal switch. It lists a deep-green Munsell 2.5G 6/3 finish and aluminium nameplate for these frames.

The terminal box is shown on the right when viewed from the drive-shaft end, with a left-side option. We can help confirm the available mounting and terminal-box arrangement. For direction changes, terminal connections and protection, follow the original diagrams and instructions for your motor; the catalogue's wiring groups distinguish motors up to 1.1 kW with thermal protection from larger dual-voltage motors. We have not reconstructed wiring from a text extract.

Use the dimensions for the selected mounting and source edition. The original outlines are marked typical dimensions only—ask us for certified dimensions before final installation. Catalogue dimensions are in millimetres; the individual outlines do not explicitly state general dimensional units, so their callouts are retained as printed. Blank entries are not zero or an invitation to infer a missing measurement.

Details to confirm with our team

Where our published information differs, we retain each source's wording or value and identify what needs confirmation.

Selection / sheetFieldDatasheetCatalogue
0.25 kW / 2P · Datasheet-510.pdfFrame designationD71 A71
0.25 kW / 4P · Datasheet-516.pdfFrame designationD71 A71
0.37 kW / 2P · Datasheet-511.pdfPOWER FACTOR / 100% LOAD80 %81.00 %
0.37 kW / 2P · Datasheet-511.pdfFrame designationD71 A71
0.37 kW / 4P · Datasheet-517.pdfFrame designationD71 B71
0.55 kW / 2P · Datasheet-512.pdfFrame designationD71 B71
0.18 kW / 4P · Datasheet-515.pdfFrame designationD71 A71

Catalogue current/torque ratios and power factors were compared on the same percentage basis as the datasheets. Original ratios, supply pairs and frame labels remain unchanged below. Frame designation differences are retained as labels, not automatically treated as equivalent frames.

BEGY catalogue specifications

Our shared single-phase catalogue includes several product families. These tables retain shared operating context, the BEGY performance and spare-parts rows, and the steel-frame mounting schedules—including the flange-only BETY tables. BECY/BEDY and B56-only tables are excluded from this guide. Where a shared paragraph still names another family or voltage, it is explicitly scoped and does not extend the BEGY rating. Every catalogue page remains linked to its original edition.

Catalogue page 1 — Cover and whole-catalogue range; BEGY range stated in guide.

Catalogue range and navigation

Catalogue page 2

Catalogue context / Range

Property Value Unit
BEGY Single Phase Motor, Type CSR; Series BEGY; Frame size 71–80; Output 0.18–1.1kW.

Catalogue context

Property Value Unit
Contents Motor range p2; standard specification p3; general description p4; motor classification and selection p5; connection diagram p5; schematic drawings p6; terminal connection p6; performance data p7; dimension drawings IM1001 p8, IM3001 p9, IM2001 p10, B56 p11; spare parts p11; company addresses p12.

Shared standard specification

Catalogue page 3

Shared catalogue reference: this page also names other frame sizes, outputs, supplies and mountings. Those entries are not blanket BEGY specifications. Use the selected BEGY source and confirm any conflicting limits.

Ratings and specifications / Rating

Property Value Unit
Voltage Rated Voltage 240V/480V
Frequency Rated Frequency 50Hz
Output range 0.18kW – 7.5kW
R.P.M. (Syn.) 3000R.P.M. (2 Pole); 1500R.P.M. (4 Pole)
Duty S1 (Continuous)
Frame size 71 – 132M
Enclosure TEFC Totally Enclosed Fan Cooled
Degree of protection IP 44 (Totally Enclosed, Splash Proof)
Method of cooling IC 0141 External Fan. Surface Cooling
Mounting IM 1001 Foot Mounting; IM 3001 Flange Mounting; IM 2001 Foot & Flange Mounting

Ratings and specifications / Application

Property Value Unit
Power condition Voltage ±10%, Frequency ±5%.
Environment conditions Area = Non Hazardous. Ambient Temperature −10°C to 40°C. Relative Humidity = Max. 90%. Altitude = Max. 1000m (3300ft).
Drive method Belt Drive or Direct Coupling
Direction of rotation Bi-Directional
Method of starting D.O.L. (Direct-On-Line) Full Voltage

Ratings and specifications / Construction

Property Value Unit
Frame 71 – 80 Rolled Steel; 90 – 132 Cast Iron
Endshield 71 – 80 Alum. Alloy with Steel Insert, except Frame 80 DE (Cast Iron); 90 – 132 Cast Iron
External fan Polypropylene
Fan cover Pressed Steel
Bearing Single Row Deep Groove Ball Bearing – Double Shields, Pre-Greased
Terminal box Pressed Steel, with Clearance Hole Cable Entry
Stator winding Polyester Enamelled Copper Wires, Random Wound
Insulation system Class F (Operating Temp. 155°C – Temp. Rise 105°C)
Rotor Squirrel Cage. Alum. Conductor with End-Ring
Painting Phenolic Base Paint, Laquer Surface Finish; 71 – 80 Munsell 2.5G 6/3 (Deep Green); 90 – 132 Munsell N5.0 – SG (Grey)
Name plate 71 – 80 Aluminium; 90 – 132 Stainless Steel
Bolts ISO Metric System (Except B56)

Ratings and specifications / Performance

Property Value Unit
Temperature rise Not Exceeding 90°C by Resistance Method
Over speed 125% Syn. R.P.M. for one min.
Over torque 160% Rated Torque for 15 sec.
Capacitor start Series BEGY/BETY and BECY/BEDY: Capacitor Start – Capacitor Run. Series B56: Cap. Start – Cap. Run and Cap. Start – Induction Run.
Standards Comply with relevant IEC & AS Standards

Ratings, construction and options

Catalogue page 4

Shared catalogue reference: this page also names other frame sizes, outputs, supplies and mountings. Those entries are not blanket BEGY specifications. Use the selected BEGY source and confirm any conflicting limits.

Catalogue context

Property Value Unit
Connection 240 Volts Single Phase 50Hz for motors of 0.18kW to 7.5kW. 240/480 Volts Single Phase 50Hz from 1.5 to 7.5kW. The motors will produce their rated performance with voltage +/−5 per cent.
Rating Continuously rated at name plate current defined as S1 to AS 1359 within an ambient temperature −10 to 40°C, and altitude below 1000 metres. For higher ambients and/or altitudes the output rating must be adjusted accordingly; contact TECO.
Performance Standard motors are designed with performance in accordance with relevant standards within IEC34 and AS 1359 & 1360.
Direction of rotation Suitable for operation in either direction. Reversing direction uses the connection link within the terminal box; source refers to page 6. Original diagrams remain the authority.
Mounting Foot: IM1001, 1011, 1031, 1051, 1061, 1071. Flange: IM3001, 3011, 3031. Foot and Flange: IM2001. According to AS 1359 and IEC72.
Frame Two pole motors up to 1.1kW, four pole motors up to 0.75kW and Series B56 motors are rolled steel. Larger motors are high-grade cast iron with longitudinal cooling fins and integrally cast feet.
Fan and fan cowl Bi-directional cooling fans of polypropylene; pressed-steel fan cowl painted internally and externally to resist corrosion.
Bearings and lubrication Double shielded, pre-packed ball bearings sealed against dust and moisture; source states no further attention for the life of the bearing.
Stator winding and insulation High-grade insulated cold-rolled electromagnetic steel laminations; Class F insulation system. Source states resistance to tropical and high-humidity conditions. All motors incorporate a centrifugal switch between the starting and running windings.
Rotor assembly One-piece pressure die-cast aluminium rotor conductors and end rings; rotating parts dynamically balanced to minimise vibration.
Terminal box Pressed steel terminal box at the right-hand side when looking at the drive shaft end; left-hand side optional. Connections shown on source page 6.
Capacitors BEGY 0.25–1.1kW (2P) and BECY 1.1kW (4P) to 7.5kW are capacitor start capacitor run. B56 0.75kW 2-pole and 0.25–0.55kW 4-pole are capacitor start induction run; B56 0.75kW 4-pole is capacitor start capacitor run.
Paint finish Castings and steel parts have a phenolic-base prime coat and synthetic enamel paint finish.

Starting arrangements and selection

Catalogue page 5

Shared catalogue reference: this page also names other frame sizes, outputs, supplies and mountings. Those entries are not blanket BEGY specifications. Use the selected BEGY source and confirm any conflicting limits.

Catalogue context

Property Value Unit
Classification CSIR = Capacitor Start – Induction Run. CSR = Capacitor Start – Capacitor Run.
Selection Selection depends on starting and running torque requirements, duty cycle and power-supply starting/running current limits. Source says TECO can manufacture single-phase motors for various applications.
CSIR characteristics High starting torque and medium starting current; source describes suitability for heavier duty applications and power supplies with higher voltage variation.
CSR characteristics Combines high starting torque and good running performance. Source describes use for integral-rating applications with heavier starting torque requirements.
Source stock and protector note Source states CSIR and CSR motors are stocked by TECO Australia, and single-voltage motors are normally fitted with thermal protectors. Historical catalogue statement; not current inventory proof.
Connection diagram context Separate C.C.W. and C.W. rotation diagrams for CSIR at 240V and CSR at 240V/480V. No wiring connections reconstructed; consult original page.

Terminal connection reference

Catalogue page 6

Shared catalogue reference: this page also names other frame sizes, outputs, supplies and mountings. Those entries are not blanket BEGY specifications. Use the selected BEGY source and confirm any conflicting limits.

Catalogue context

Property Value Unit
Terminal connection context Printed groups: 1.1kW and below with Thermal Protector (240V), and 1.5kW and above without Thermal Protector (240V/480V); C.C.W. and C.W. diagrams. Original diagrams govern connections; geometry is not encoded here.

Schematic legend / Frame 71–80

Property Value Unit
1 Fan Cover part label
2 Fan part label
3 End shield N-End part label
4 Centrifugal Switch part label
5 Stator Frame part label
6 Stator part label
7 Rotor part label
8 End shield D-End part label
9 Bearing part label
10 Shaft part label
11 Terminal Box part label
12 Capacitor Box part label

BEGY performance data

Catalogue page 7

Performance data

Conditions: Four printed row groups: main-range 2-pole, main-range 4-pole, B56 2-pole, B56 4-pole. A dash is preserved as a source dash, not zero. Only the listed frame/output/pole combination is covered; source association with a product does not make all rows applicable to that product. 240/480V supply distinctions and start/run capacitors remain separate. Notes/formulas are retained in the page commentary.

Poles (poles) Rated output (kW) Frame size Speed (RPM) Efficiency (%) Power factor cosφ (dimensionless) Full-load current 240V (A) Full-load current 480V (A) Starting current ratio 240V (Ist/IN) Starting current ratio 480V (Ist/IN) Full-load torque (Nm) Starting torque ratio (Tst/TN) Breakdown torque ratio (Tb/TN) Start capacitor (µF) Start capacitor rated voltage (Vac) Run capacitor (µF) Run capacitor rated voltage (Vac)
2 0.25 A71 2880 65.9 0.80 1.96 — 5.1 — 0.78 2.6 2.8 40 250 4 440
2 0.37 A71 2870 72.4 0.81 2.66 — 4.9 — 1.27 2.3 2.3 50 250 5 440
2 0.55 B71 2865 73 0.86 3.74 — 5.9 — 1.86 2.7 2.4 80 250 8 440
2 0.75 80 2900 74 0.87 4.84 — 7 — 2.45 3.2 2.8 100 250 10 440
2 1.1 80 2880 75.5 0.94 6.6 — 6.5 — 3.6 2.4 2.5 125 250 15 440
4 0.18 A71 1430 63.5 0.72 1.7 — 4.7 — 1.18 2.7 2.4 40 250 4 440
4 0.25 A71 1420 64.3 0.75 2.12 — 4.7 — 1.66 2.3 2.3 40 250 4 440
4 0.37 B71 1415 68.7 0.78 2.9 — 5.2 — 2.45 2.2 2.3 70 250 6 440
4 0.55 80 1425 70.1 0.77 4.3 — 5.1 — 3.7 2.6 1.8 80 250 8 440
4 0.75 80 1425 72.1 0.86 5 — 5.8 — 5 2.5 2.2 100 250 12 440

Source conditions: Tolerances according to IEC 34-1 and AS 1359.60. Efficiency — 15(1−η)% when P2 ≤50kW. Power factor cosφ — (1−cosφ)/6, minimum 0.02, maximum 0.07. Torque TN = (9550 × kW)/RPM Nm. Data subject to change without notice.

Catalogue context

Property Value Unit
Definitions and conversions 1kW = 1.34HP; 1HP = 0.746kW; 1Nm = 0.102kgmf. Ist/IN = Starting Current/Nominal F.L. Current; Tst/TN = Starting Torque/Nominal F.L. Torque; Tb/TN = Break down Torque/Nominal F.L. Torque.

Foot mounting IM1001

Catalogue page 8

IM1001 overall and mounting dimensions

Conditions: Dimensions in mm unless an explicit inch, rating, part or mass unit is printed. Values in explicitly merged cells are repeated only within their source row span. Empty output cells remain blank, not an inferred additional variant. Geometry remains in the original. Design, data and dimensions subject to modification without notice.

Series Frame Output 2P (kW) Output 4P (kW) Figure (figure reference) A (mm) AA (mm) AB (mm) AC (mm) AD (mm) AE (mm) B (mm) BA (mm) BB (mm) C (mm) H (mm) HA (mm) HC (mm) HD (mm) HE (mm) K (mm) KK (mm)
BEGY A71 0.25 0.18 1 112 40 150 144 114 86 90 30 120 45 71 3.2 177 31 10 22
BEGY A71 0.37 0.25 1 112 40 150 144 114 86 90 30 120 45 71 3.2 182 31 10 22
BEGY B71 0.37 1 112 40 150 144 114 86 90 30 120 45 71 3.2 182 31 10 22
BEGY B71 0.55 1 112 40 150 144 114 86 90 30 120 45 71 3.2 187 31 10 22
BEGY 80 0.75 0.55 1 125 40 165 163 122 94 100 30 130 50 80 3.2 205 40 10 22
BEGY 80 0.75 1 125 40 165 163 122 94 100 30 130 50 80 3.2 205 40 10 22
BEGY 80 1.1 1 125 40 165 163 122 94 100 30 130 50 80 3.2 211 40 10 22

IM1001 shaft bearing and approximate mass

Series Frame Output 2P (kW) Output 4P (kW) Figure (figure reference) L (mm) LE (mm) LL (mm) Z (mm) D (mm) E (mm) ED (mm) F (mm) G (mm) GA (mm) Bearing D-END Bearing ND-END Approx. mass 2P (kg) Approx. mass 4P (kg)
BEGY A71 0.25 0.18 1 269 104 104 20 14 30 14 5 11 16 6202 ZZ 6202 ZZ 7.5 7.5
BEGY A71 0.37 0.25 1 269 104 104 20 14 30 14 5 11 16 6202 ZZ 6202 ZZ 8.3 8.5
BEGY B71 0.37 1 287 122 122 20 14 30 14 5 11 16 6202 ZZ 6202 ZZ 10
BEGY B71 0.55 1 287 122 122 20 14 30 14 5 11 16 6202 ZZ 6202 ZZ 9.7
BEGY 80 0.75 0.55 1 307 117 123 20 19 40 25 6 15.5 21.5 6204 ZZ 6202 ZZ 13.5 12
BEGY 80 0.75 1 307 117 123 20 19 40 25 6 15.5 21.5 6204 ZZ 6202 ZZ 14
BEGY 80 1.1 1 307 117 123 20 19 40 25 6 15.5 21.5 6204 ZZ 6202 ZZ 15.5

Flange mounting IM3001 — BETY catalogue designation

Catalogue page 9

IM3001 flange dimensions

Conditions: Dimensions in mm unless an explicit inch, rating, part or mass unit is printed. Values in explicitly merged cells are repeated only within their source row span. Empty output cells remain blank, not an inferred additional variant. Geometry remains in the original. Design, data and dimensions subject to modification without notice. Series are BETY/BEDY on this page; not silently relabelled BEGY/BECY.

Series Frame Output 2P (kW) Output 4P (kW) Figure (figure reference) AD (mm) AE (mm) HB (mm) HC (mm) KK (mm) L (mm) LA (mm) LB (mm) M (mm) N (mm) P (mm) S (mm) T (mm)
BETY A71 0.25 0.18 1 114 86 180 22 294 10 271 115 95 140 10 3
BETY A71 0.25 1 114 86 186 22 301 10 271 130 110 160 10 3.5
BETY A71 0.37 1 114 86 191 22 301 10 271 130 110 160 10 3.5
BETY B71 0.37 1 114 86 191 22 319 10 289 130 110 160 10 3.5
BETY B71 0.55 1 114 86 196 22 319 10 289 130 110 160 10 3.5
BETY 80 0.75 0.55 1 122 94 225 22 325 12 295 165 130 200 12 3.5
BETY 80 0.75 1 122 94 225 22 335 12 315 165 130 200 12 3.5
BETY 80 1.1 1 122 94 231 22 335 12 315 165 130 200 12 3.5

IM3001 shaft and bearing dimensions

Conditions: Dimensions in mm unless an explicit inch, rating, part or mass unit is printed. Values in explicitly merged cells are repeated only within their source row span. Empty output cells remain blank, not an inferred additional variant. Geometry remains in the original. Design, data and dimensions subject to modification without notice. Printed tolerance text: D = <28-j6, 38k6; F = h9; H = +0 −0.5; N = js6. Do not infer an unstated D=28 tolerance.

Series Frame Output 2P (kW) Output 4P (kW) Figure (figure reference) D (mm) E (mm) ED (mm) F (mm) G (mm) GA (mm) Bearing D-END Bearing ND-END
BETY A71 0.25 0.18 1 11 23 10 4 8.5 12.5 6202 ZZ 6202 ZZ
BETY A71 0.25 1 14 30 14 5 11 16 6202 ZZ 6202 ZZ
BETY A71 0.37 1 14 30 14 5 11 16 6202 ZZ 6202 ZZ
BETY B71 0.37 1 14 30 14 5 11 16 6202 ZZ 6202 ZZ
BETY B71 0.55 1 14 30 14 5 11 16 6202 ZZ 6202 ZZ
BETY 80 0.75 0.55 1 19 40 25 6 15.5 21.5 6204 ZZ 6202 ZZ
BETY 80 0.75 1 19 40 25 6 15.5 21.5 6204 ZZ 6202 ZZ
BETY 80 1.1 1 19 40 25 6 15.5 21.5 6204 ZZ 6202 ZZ

IM3001 tolerance

Property Value Unit
D <28-j6, 38k6
F h9
H +0 −0.5
N js6

Drawing callout

Property Value Unit
Flange figures 1–3 45°

Foot and flange mounting IM2001

Catalogue page 10

IM2001 foot and flange dimensions

Conditions: Dimensions in mm unless an explicit inch, rating, part or mass unit is printed. Values in explicitly merged cells are repeated only within their source row span. Empty output cells remain blank, not an inferred additional variant. Geometry remains in the original. Design, data and dimensions subject to modification without notice.

Series Frame Output 2P (kW) Output 4P (kW) Figure (figure reference) A (mm) AA (mm) AB (mm) AD (mm) AE (mm) B (mm) BA (mm) BB (mm) C (mm) H (mm) HA (mm) HC (mm) HD (mm) HE (mm) K (mm) KK (mm) L (mm) LA (mm) LB (mm)
BEGY A71 0.25 0.18 1 112 40 150 114 86 90 30 120 77 71 3.2 177 31 10 22 301 10 271
BEGY A71 0.25 1 112 40 150 114 86 90 30 120 77 71 3.2 177 31 10 22 301 10 271
BEGY A71 0.37 1 112 40 150 114 86 90 30 120 77 71 3.2 182 31 10 22 301 10 271
BEGY B71 0.37 112 40 150 114 86 90 30 120 77 71 3.2 182 31 10 22 319 10 289
BEGY B71 0.55 112 40 150 114 86 90 30 120 77 71 3.2 187 31 10 22 319 10 289
BEGY 80 0.75 0.55 1 125 40 165 122 94 100 30 130 77.5 80 3.2 205 40 10 22 335 12 295
BEGY 80 0.75 1 125 40 165 122 94 100 30 130 77.5 80 3.2 205 40 10 22 355 12 315
BEGY 80 1.1 1 125 40 165 122 94 100 30 130 77.5 80 3.2 211 40 10 22 355 12 315

IM2001 flange shaft and bearing dimensions

Series Frame Output 2P (kW) Output 4P (kW) Figure (figure reference) LL (mm) M (mm) N (mm) P (mm) S (mm) T (mm) Z (mm) D (mm) E (mm) ED (mm) F (mm) G (mm) GA (mm) Bearing D-END Bearing ND-END
BEGY A71 0.25 0.18 1 104 130 110 160 10 3.5 20 14 30 14 5 11 16 6202 ZZ 6202 ZZ
BEGY A71 0.25 1 104 130 110 160 10 3.5 20 14 30 14 5 11 16 6202 ZZ 6202 ZZ
BEGY A71 0.37 1 104 130 110 160 10 3.5 20 14 30 14 5 11 16 6202 ZZ 6202 ZZ
BEGY B71 0.37 122 130 110 160 10 3.5 20 14 30 14 5 11 16 6202 ZZ 6202 ZZ
BEGY B71 0.55 122 130 110 160 10 3.5 20 14 30 14 5 11 16 6202 ZZ 6202 ZZ
BEGY 80 0.75 0.55 1 123 165 130 200 12 3.5 20 19 40 25 6 15.5 21.5 6204 ZZ 6202 ZZ
BEGY 80 0.75 1 143 165 130 200 12 3.5 20 19 40 25 6 15.5 21.5 6204 ZZ 6202 ZZ
BEGY 80 1.1 1 143 165 130 200 12 3.5 20 19 40 25 6 15.5 21.5 6204 ZZ 6202 ZZ

BEGY spare parts

Catalogue page 11

Spare parts list

Conditions: Dimensions in mm unless an explicit inch, rating, part or mass unit is printed. Values in explicitly merged cells are repeated only within their source row span. Empty output cells remain blank, not an inferred additional variant. Geometry remains in the original. Design, data and dimensions subject to modification without notice. Original kW–P column is split into output and pole count only. Capacitor ranges and x2/x4 multiplicity remain verbatim; no summed/replacement capacitor is inferred. Dashes are printed source dashes, not zeros.

Type Output (kW) Poles (poles) Centrifugal switch (part code) Capacitor START Capacitor RUN Thermal overload (part code) Bearing D-END Bearing ND-END
BEGYBS 0.18 4 TS1RA4517 40uf 250V AC 4uf 440V AC MRA 68164 6202 ZZ 6202 ZZ
BEGYBS 0.25 2 TS1RA2517 40uf 250V AC 4uf 440V AC MRA 68163 6202 ZZ 6202 ZZ
BEGYBS 0.25 4 TS1RA4517 40uf 250V AC 4uf 440V AC MRA 68163 6202 ZZ 6202 ZZ
BEGYBS 0.37 2 TS1RA2517 50uf 250V AC 5uf 440V AC MRA 68225 6202 ZZ 6202 ZZ
BEGYBS 0.37 4 TS1RA4517 70uf 250V AC 6uf 440V AC MRA 68225 6202 ZZ 6202 ZZ
BEGYBS 0.55 2 TS1RA2517 80uf 250V AC 8uf 440V AC MRA 68223 6202 ZZ 6202 ZZ
BEGYBS 0.55 4 TS1RA4517 80uf 250V AC 8uf 440V AC MRA 68223 6204 ZZ 6202 ZZ
BEGYBS 0.75 2 TS1RA2517 100uf 250V AC 10uf 440V AC MRA 68363 6204 ZZ 6202 ZZ
BEGYBS 0.75 4 TS1RA4517 100uf 250V AC 12uf 440V AC MRA 68363 6204 ZZ 6202 ZZ
BEGYBS 1.1 2 TS1RA2517 125uf 250V AC 15uf 440V AC MRA 68364 6204 ZZ 6202 ZZ

Catalogue page 12 — Historical contact back cover; current contact linked.

Individual datasheets and drawings

Each source retains its own ratings, missing fields and qualifications. The drawing sections also include 535 named dimensional callouts read from the 21 original outlines, including fits, shaft details, mounting holes and flange dimensions. Use the linked originals for geometry and datum positions; these tables do not replace a certified drawing.

0.18BE4 , 0.25BE2.pdf

Associated selection rows: 403, 404, 405, 406, 407

PDFdrawings-517.zip > 71 FRAME/A71/0.18BE4 , 0.25BE2.pdf.

Source page 1

Conditions for this section:

  • C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / frame_as_printed A71 as printed —
Drawing / Phase 1 as printed C1
Drawing / Construction Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor as printed C1
Drawing note / 1 Foot mounted IM1001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 For belt or direct drive. as printed —

Printed rating table — P049, 0.18BE4 , 0.25BE2.pdf, page 1

Conditions for this section:

  • C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 0.25 kW 0.33 HP 3000 rpm (synchronous, as headed) C1
2 4 poles 0.18 kW 0.25 HP 1500 rpm (synchronous, as headed) C1

Dimensions read from this original outline

Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.

Drawing callout Printed value
Transverse mounting-hole centres 112
Foot overall width 150
Foot slot-group width callout 40
Foot thickness 3.2
Shaft height and tolerance 71 +0/−0.5
Lower terminal enclosure height above foot plane 31
Axial foot slot-group callout 30
Axial mounting-hole centres 90
Foot overall axial length 120
Cable-entry diameter Ø22
Shaft diameter and fit Ø14 j6
Key width 5
Shaft keyseat lower-height callout 11
Shaft-and-key top height 16
Shaft-end thread and depth M5 TAP DEEP 7.5
Foot slot detail: length × width 20 × 10
Shaft extension 30
Key length callout 14
Overall axial length 269
Shaft-centre to terminal enclosure outer edge 147
Shaft-centre to cable-entry axis 86
Front-view body width callout 144
Front-view overall vertical envelope 177
Shaft shoulder to nearer foot-hole centre 45
Rear foot-hole centre to fan end 104
Upper axial callout from fan end to drawn reference 104

0.18BV4 , 0.25BV2.pdf

Associated selection rows: 403, 404, 405, 406, 407

PDFdrawings-517.zip > 71 FRAME/A71/0.18BV4 , 0.25BV2.pdf.

Source page 1

Conditions for this section:

  • C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / frame_as_printed A71 (63 FLANGE) as printed —
Drawing / Phase 1 as printed C1
Drawing / Construction Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor as printed C1
Drawing note / 1 Flange mounted IM3001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 For belt or direct drive. as printed —

Printed rating table — P049, 0.18BV4 , 0.25BV2.pdf, page 1

Conditions for this section:

  • C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 0.25 kW 0.33 HP 3000 rpm (synchronous, as headed) C1
2 4 poles 0.18 kW 0.25 HP 1500 rpm (synchronous, as headed) C1

Dimensions read from this original outline

Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.

Drawing callout Printed value
Overall axial length 294
Flange face to fan end 271
Shaft extension 23
Key length callout 10
Shaft-centre to terminal enclosure outer edge 114
Shaft-centre to cable-entry axis 86
Front-view overall vertical envelope 180
Cable-entry diameter Ø22
Shaft diameter and fit Ø11 j6
Key width 4
Shaft keyseat lower-height callout 8.5
Shaft-and-key top height 12.5
Shaft-end thread and depth M4 TAP DEEP 6
Flange bolt pitch-circle diameter Ø115
Flange pilot diameter and fit Ø95 h7
Flange outer diameter Ø140
Flange bolt holes 4-Ø10 Holes
Flange thickness 10
Flange register projection 3
Flange-hole angular offset 45

0.25BF2 , 0.18BF4 , 0.25BF4.pdf

Associated selection rows: 403, 404, 405, 406, 407

PDFdrawings-517.zip > 71 FRAME/A71/0.25BF2 , 0.18BF4 , 0.25BF4.pdf.

Source page 1

Conditions for this section:

  • C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / frame_as_printed A71 as printed —
Drawing / Phase 1 as printed C1
Drawing / Construction Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor as printed C1
Drawing note / 1 Foot & flange mounted IM2001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 For belt or direct drive. as printed —

Printed rating table — P049, 0.25BF2 , 0.18BF4 , 0.25BF4.pdf, page 1

Conditions for this section:

  • C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 0.25 kW 0.33 HP 3000 rpm (synchronous, as headed) C1
2 4 poles 0.18/0.25 kW 0.25/0.33 HP 1500 rpm (synchronous, as headed) C1

Dimensions read from this original outline

Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.

Drawing callout Printed value
Transverse mounting-hole centres 112
Foot overall width 150
Foot slot-group width callout 40
Foot thickness 3.2
Shaft height and tolerance 71 +0/−0.5
Lower terminal enclosure height above foot plane 31
Axial foot slot-group callout 30
Axial mounting-hole centres 90
Foot overall axial length 120
Cable-entry diameter Ø22
Shaft diameter and fit Ø14 j6
Key width 5
Shaft keyseat lower-height callout 11
Shaft-and-key top height 16
Shaft-end thread and depth M5 TAP DEEP 7.5
Foot slot detail: length × width 20 × 10
Shaft extension 30
Key length callout 14
Flange bolt pitch-circle diameter Ø130
Flange pilot diameter and fit Ø110 h7
Flange outer diameter Ø160
Flange bolt holes 4-Ø10 Holes
Flange thickness 10
Flange register projection 3.5
Overall axial length 301
Flange face to fan end 271
Shaft-centre to terminal enclosure outer edge 114
Shaft-centre to cable-entry axis 86
Front-view overall vertical envelope 177
Axial front mounting offset as drawn 77
Rear foot-hole centre to fan end 115
Upper axial callout from fan end to drawn reference 104

0.25BV4.pdf

Associated selection rows: 403, 404, 405, 406, 407

PDFdrawings-517.zip > 71 FRAME/A71/0.25BV4.pdf.

Source page 1

Conditions for this section:

  • C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / frame_as_printed A71 as printed —
Drawing / Phase 1 as printed C1
Drawing / Construction Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor as printed C1
Drawing note / 1 Flange mounted IM3001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 For belt or direct drive. as printed —

Printed rating table — P049, 0.25BV4.pdf, page 1

Conditions for this section:

  • C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 4 poles 0.25 kW 0.33 HP 1500 rpm (synchronous, as headed) C1

Dimensions read from this original outline

Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.

Drawing callout Printed value
Cable-entry diameter Ø22
Shaft diameter and fit Ø14 j6
Key width 5
Shaft keyseat lower-height callout 11
Shaft-and-key top height 16
Shaft-end thread and depth M5 TAP DEEP 7.5
Shaft extension 30
Key length callout 14
Flange bolt pitch-circle diameter Ø130
Flange pilot diameter and fit Ø110 h7
Flange outer diameter Ø160
Flange bolt holes 4-Ø10 Holes
Flange thickness 10
Flange register projection 3.5
Flange-hole angular offset 45
Overall axial length 301
Flange face to fan end 271
Shaft-centre to terminal enclosure outer edge 114
Shaft-centre to cable-entry axis 86
Front-view overall vertical envelope 186

0.37BE2 , 0.25BE4.pdf

Associated selection rows: 403, 404, 405, 406, 407

PDFdrawings-517.zip > 71 FRAME/A71/0.37BE2 , 0.25BE4.pdf.

Source page 1

Conditions for this section:

  • C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / frame_as_printed A71 as printed —
Drawing / Phase 1 as printed C1
Drawing / Construction Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor as printed C1
Drawing note / 1 Foot mounted IM1001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 For belt or direct drive. as printed —

Printed rating table — P049, 0.37BE2 , 0.25BE4.pdf, page 1

Conditions for this section:

  • C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 0.37 kW 0.50 HP 3000 rpm (synchronous, as headed) C1
2 4 poles 0.25 kW 0.33 HP 1500 rpm (synchronous, as headed) C1

Dimensions read from this original outline

Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.

Drawing callout Printed value
Transverse mounting-hole centres 112
Foot overall width 150
Foot slot-group width callout 40
Foot thickness 3.2
Shaft height and tolerance 71 +0/−0.5
Lower terminal enclosure height above foot plane 31
Axial foot slot-group callout 30
Axial mounting-hole centres 90
Foot overall axial length 120
Cable-entry diameter Ø22
Shaft diameter and fit Ø14 j6
Key width 5
Shaft keyseat lower-height callout 11
Shaft-and-key top height 16
Shaft-end thread and depth M5 TAP DEEP 7.5
Foot slot detail: length × width 20 × 10
Shaft extension 30
Key length callout 14
Overall axial length 269
Shaft-centre to terminal enclosure outer edge 147
Shaft-centre to cable-entry axis 86
Front-view body width callout 144
Front-view overall vertical envelope 182
Shaft shoulder to nearer foot-hole centre 45
Rear foot-hole centre to fan end 104
Upper axial callout from fan end to drawn reference 104

0.37BE4.pdf

Associated selection rows: 403, 404, 405, 406, 407

PDFdrawings-517.zip > 71 FRAME/B71/0.37BE4.pdf.

Source page 1

Conditions for this section:

  • C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / frame_as_printed B71 as printed —
Drawing / Phase 1 as printed C1
Drawing / Construction Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor as printed C1
Drawing note / 1 Foot mounted IM1001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 For belt or direct drive. as printed —

Printed rating table — P049, 0.37BE4.pdf, page 1

Conditions for this section:

  • C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 4 poles 0.37 kW 0.50 HP 1500 rpm (synchronous, as headed) C1

Dimensions read from this original outline

Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.

Drawing callout Printed value
Transverse mounting-hole centres 112
Foot overall width 150
Foot slot-group width callout 40
Foot thickness 3.2
Shaft height and tolerance 71 +0/−0.5
Lower terminal enclosure height above foot plane 31
Axial foot slot-group callout 30
Axial mounting-hole centres 90
Foot overall axial length 120
Cable-entry diameter Ø22
Shaft diameter and fit Ø14 j6
Key width 5
Shaft keyseat lower-height callout 11
Shaft-and-key top height 16
Shaft-end thread and depth M5 TAP DEEP 7.5
Foot slot detail: length × width 20 × 10
Shaft extension 30
Key length callout 14
Overall axial length 287
Shaft-centre to terminal enclosure outer edge 147
Shaft-centre to cable-entry axis 86
Front-view body width callout 144
Front-view overall vertical envelope 182
Shaft shoulder to nearer foot-hole centre 45
Rear foot-hole centre to fan end 122
Upper axial callout from fan end to drawn reference 122

0.37BF2.pdf

Associated selection rows: 403, 404, 405, 406, 407

PDFdrawings-517.zip > 71 FRAME/A71/0.37BF2.pdf.

Source page 1

Conditions for this section:

  • C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / frame_as_printed A71 as printed —
Drawing / Phase 1 as printed C1
Drawing / Construction Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor as printed C1
Drawing note / 1 Foot & flange mounted IM2001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 For belt or direct drive. as printed —

Printed rating table — P049, 0.37BF2.pdf, page 1

Conditions for this section:

  • C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 0.37 kW 0.50 HP 3000 rpm (synchronous, as headed) C1

Dimensions read from this original outline

Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.

Drawing callout Printed value
Transverse mounting-hole centres 112
Foot overall width 150
Foot slot-group width callout 40
Foot thickness 3.2
Shaft height and tolerance 71 +0/−0.5
Lower terminal enclosure height above foot plane 31
Axial foot slot-group callout 30
Axial mounting-hole centres 90
Foot overall axial length 120
Cable-entry diameter Ø22
Shaft diameter and fit Ø14 j6
Key width 5
Shaft keyseat lower-height callout 11
Shaft-and-key top height 16
Shaft-end thread and depth M5 TAP DEEP 7.5
Foot slot detail: length × width 20 × 10
Shaft extension 30
Key length callout 14
Flange bolt pitch-circle diameter Ø130
Flange pilot diameter and fit Ø110 h7
Flange outer diameter Ø160
Flange bolt holes 4-Ø10 Holes
Flange thickness 10
Flange register projection 3.5
Overall axial length 301
Flange face to fan end 271
Shaft-centre to terminal enclosure outer edge 114
Shaft-centre to cable-entry axis 86
Front-view overall vertical envelope 182
Axial front mounting offset as drawn 77
Rear foot-hole centre to fan end 115
Upper axial callout from fan end to drawn reference 104

0.37BF4.pdf

Associated selection rows: 403, 404, 405, 406, 407

PDFdrawings-517.zip > 71 FRAME/B71/0.37BF4.pdf.

Source differences and limitations

  • Printed note says foot & flange mounted IM3001; wording and code retained together.

Source page 1

Conditions for this section:

  • C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / frame_as_printed B71 as printed —
Drawing / Phase 1 as printed C1
Drawing / Construction Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor as printed C1
Drawing note / 1 Foot & flange mounted IM3001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 For belt or direct drive. as printed —

Printed rating table — P049, 0.37BF4.pdf, page 1

Conditions for this section:

  • C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 4 poles 0.37 kW 0.50 HP 1500 rpm (synchronous, as headed) C1

Dimensions read from this original outline

Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.

Drawing callout Printed value
Transverse mounting-hole centres 112
Foot overall width 150
Foot slot-group width callout 40
Foot thickness 3.2
Shaft height and tolerance 71 +0/−0.5
Lower terminal enclosure height above foot plane 31
Axial foot slot-group callout 30
Axial mounting-hole centres 90
Foot overall axial length 120
Cable-entry diameter Ø22
Shaft diameter and fit Ø14 j6
Key width 5
Shaft keyseat lower-height callout 11
Shaft-and-key top height 16
Shaft-end thread and depth M5 TAP DEEP 7.5
Foot slot detail: length × width 20 × 10
Shaft extension 30
Key length callout 14
Flange bolt pitch-circle diameter Ø130
Flange pilot diameter and fit Ø110 h7
Flange outer diameter Ø160
Flange bolt holes 4-Ø10 Holes
Flange thickness 10
Flange register projection 3.5
Overall axial length 319
Flange face to fan end 289
Shaft-centre to terminal enclosure outer edge 114
Shaft-centre to cable-entry axis 86
Front-view overall vertical envelope 182
Axial front mounting offset as drawn 77
Rear foot-hole centre to fan end 122
Upper axial callout from fan end to drawn reference 122

0.37BV2.pdf

Associated selection rows: 403, 404, 405, 406, 407

PDFdrawings-517.zip > 71 FRAME/A71/0.37BV2.pdf.

Source page 1

Conditions for this section:

  • C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / frame_as_printed A71 as printed —
Drawing / Phase 1 as printed C1
Drawing / Construction Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor as printed C1
Drawing note / 1 Flange mounted IM3001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 For belt or direct drive. as printed —

Printed rating table — P049, 0.37BV2.pdf, page 1

Conditions for this section:

  • C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 0.37 kW 0.50 HP 3000 rpm (synchronous, as headed) C1

Dimensions read from this original outline

Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.

Drawing callout Printed value
Cable-entry diameter Ø22
Shaft diameter and fit Ø14 j6
Key width 5
Shaft keyseat lower-height callout 11
Shaft-and-key top height 16
Shaft-end thread and depth M5 TAP DEEP 7.5
Shaft extension 30
Key length callout 14
Flange bolt pitch-circle diameter Ø130
Flange pilot diameter and fit Ø110 h7
Flange outer diameter Ø160
Flange bolt holes 4-Ø10 Holes
Flange thickness 10
Flange register projection 3.5
Flange-hole angular offset 45
Overall axial length 301
Flange face to fan end 271
Shaft-centre to terminal enclosure outer edge 114
Shaft-centre to cable-entry axis 86
Front-view overall vertical envelope 191

0.37BV4.pdf

Associated selection rows: 403, 404, 405, 406, 407

PDFdrawings-517.zip > 71 FRAME/B71/0.37BV4.pdf.

Source page 1

Conditions for this section:

  • C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / frame_as_printed B71 as printed —
Drawing / Phase 1 as printed C1
Drawing / Construction Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor as printed C1
Drawing note / 1 Flange mounted IM3001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 For belt or direct drive. as printed —

Printed rating table — P049, 0.37BV4.pdf, page 1

Conditions for this section:

  • C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 4 poles 0.37 kW 0.50 HP 1500 rpm (synchronous, as headed) C1

Dimensions read from this original outline

Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.

Drawing callout Printed value
Cable-entry diameter Ø22
Shaft diameter and fit Ø14 j6
Key width 5
Shaft keyseat lower-height callout 11
Shaft-and-key top height 16
Shaft-end thread and depth M5 TAP DEEP 7.5
Shaft extension 30
Key length callout 14
Flange bolt pitch-circle diameter Ø130
Flange pilot diameter and fit Ø110 h7
Flange outer diameter Ø160
Flange bolt holes 4-Ø10 Holes
Flange thickness 10
Flange register projection 3.5
Flange-hole angular offset 45
Overall axial length 319
Flange face to fan end 289
Shaft-centre to terminal enclosure outer edge 114
Shaft-centre to cable-entry axis 86
Front-view overall vertical envelope 191

0.55BE2.pdf

Associated selection rows: 403, 404, 405, 406, 407

PDFdrawings-517.zip > 71 FRAME/B71/0.55BE2.pdf.

Source page 1

Conditions for this section:

  • C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / frame_as_printed B71 as printed —
Drawing / Phase 1 as printed C1
Drawing / Construction Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor as printed C1
Drawing note / 1 Foot mounted IM1001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 For belt or direct drive. as printed —

Printed rating table — P049, 0.55BE2.pdf, page 1

Conditions for this section:

  • C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 0.55 kW 0.75 HP 3000 rpm (synchronous, as headed) C1

Dimensions read from this original outline

Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.

Drawing callout Printed value
Transverse mounting-hole centres 112
Foot overall width 150
Foot slot-group width callout 40
Foot thickness 3.2
Shaft height and tolerance 71 +0/−0.5
Lower terminal enclosure height above foot plane 31
Axial foot slot-group callout 30
Axial mounting-hole centres 90
Foot overall axial length 120
Cable-entry diameter Ø22
Shaft diameter and fit Ø14 j6
Key width 5
Shaft keyseat lower-height callout 11
Shaft-and-key top height 16
Shaft-end thread and depth M5 TAP DEEP 7.5
Foot slot detail: length × width 20 × 10
Shaft extension 30
Key length callout 14
Overall axial length 287
Shaft-centre to terminal enclosure outer edge 147
Shaft-centre to cable-entry axis 86
Front-view body width callout 144
Front-view overall vertical envelope 187
Shaft shoulder to nearer foot-hole centre 45
Rear foot-hole centre to fan end 122
Upper axial callout from fan end to drawn reference 122

0.55BF2.pdf

Associated selection rows: 403, 404, 405, 406, 407

PDFdrawings-517.zip > 71 FRAME/B71/0.55BF2.pdf.

Source page 1

Conditions for this section:

  • C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / frame_as_printed B71 as printed —
Drawing / Phase 1 as printed C1
Drawing / Construction Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor as printed C1
Drawing note / 1 Foot & flange mounted IM2001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 For belt or direct drive. as printed —

Printed rating table — P049, 0.55BF2.pdf, page 1

Conditions for this section:

  • C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 0.55 kW 0.75 HP 3000 rpm (synchronous, as headed) C1

Dimensions read from this original outline

Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.

Drawing callout Printed value
Transverse mounting-hole centres 112
Foot overall width 150
Foot slot-group width callout 40
Foot thickness 3.2
Shaft height and tolerance 71 +0/−0.5
Lower terminal enclosure height above foot plane 31
Axial foot slot-group callout 30
Axial mounting-hole centres 90
Foot overall axial length 120
Cable-entry diameter Ø22
Shaft diameter and fit Ø14 j6
Key width 5
Shaft keyseat lower-height callout 11
Shaft-and-key top height 16
Shaft-end thread and depth M5 TAP DEEP 7.5
Foot slot detail: length × width 20 × 10
Shaft extension 30
Key length callout 14
Flange bolt pitch-circle diameter Ø130
Flange pilot diameter and fit Ø110 h7
Flange outer diameter Ø160
Flange bolt holes 4-Ø10 Holes
Flange thickness 10
Flange register projection 3.5
Overall axial length 319
Flange face to fan end 289
Shaft-centre to terminal enclosure outer edge 114
Shaft-centre to cable-entry axis 86
Front-view overall vertical envelope 187
Axial front mounting offset as drawn 77
Rear foot-hole centre to fan end 122
Upper axial callout from fan end to drawn reference 122

0.55BV2.pdf

Associated selection rows: 403, 404, 405, 406, 407

PDFdrawings-517.zip > 71 FRAME/B71/0.55BV2.pdf.

Source page 1

Conditions for this section:

  • C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / frame_as_printed B71 as printed —
Drawing / Phase 1 as printed C1
Drawing / Construction Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor as printed C1
Drawing note / 1 Flange mounted IM3001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 For belt or direct drive. as printed —

Printed rating table — P049, 0.55BV2.pdf, page 1

Conditions for this section:

  • C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 0.55 kW 0.75 HP 3000 rpm (synchronous, as headed) C1

Dimensions read from this original outline

Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.

Drawing callout Printed value
Cable-entry diameter Ø22
Shaft diameter and fit Ø14 j6
Key width 5
Shaft keyseat lower-height callout 11
Shaft-and-key top height 16
Shaft-end thread and depth M5 TAP DEEP 7.5
Shaft extension 30
Key length callout 14
Flange bolt pitch-circle diameter Ø130
Flange pilot diameter and fit Ø110 h7
Flange outer diameter Ø160
Flange bolt holes 4-Ø10 Holes
Flange thickness 10
Flange register projection 3.5
Flange-hole angular offset 45
Overall axial length 319
Flange face to fan end 289
Shaft-centre to terminal enclosure outer edge 114
Shaft-centre to cable-entry axis 86
Front-view overall vertical envelope 196

Datasheet-510.pdf

The source prints a bearing code in WEIGHT OF MOTOR. This is not a usable mass. The original entry remains below for traceability; catalogue approximate masses are separately labelled.

Associated selection rows: 403

Datasheet-510.pdf.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BEGY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 0.25 —
VOLTAGE 240 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 2 —
FRAME D71 —
SPEED / SYNCHRONOUS 3000 (rpm) —
SPEED / FULL LOAD 2880 (rpm) —
CURRENT / FULL LOAD 1.96 (Amps) —
CURRENT / LOCKED ROTOR 510 % —
TORQUE / FULL LOAD TORQUE 0.78 (Nm) —
TORQUE / STARTING TORQUE 260 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 280 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 65.9 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 80 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING Not stated (blank in source) —
WEIGHT OF MOTOR 6202 ZZ kgs —
BEARINGS / DRIVE END 6202 ZZ —
BEARINGS / NON DRIVE END 6202 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

Datasheet-516.pdf

The source prints a bearing code in WEIGHT OF MOTOR. This is not a usable mass. The original entry remains below for traceability; catalogue approximate masses are separately labelled.

Associated selection rows: 404

Datasheet-516.pdf.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BEGY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 0.25 —
VOLTAGE 240 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 4 —
FRAME D71 —
SPEED / SYNCHRONOUS 1500 (rpm) —
SPEED / FULL LOAD 1420 (rpm) —
CURRENT / FULL LOAD 2.12 (Amps) —
CURRENT / LOCKED ROTOR 470 % —
TORQUE / FULL LOAD TORQUE 1.66 (Nm) —
TORQUE / STARTING TORQUE 230 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 230 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 64.3 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 75 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING Not stated (blank in source) —
WEIGHT OF MOTOR 6202 ZZ kgs —
BEARINGS / DRIVE END 6202 ZZ —
BEARINGS / NON DRIVE END 6202 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

Datasheet-511.pdf

The source prints a bearing code in WEIGHT OF MOTOR. This is not a usable mass. The original entry remains below for traceability; catalogue approximate masses are separately labelled.

Associated selection rows: 405

Datasheet-511.pdf.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BEGY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 0.37 —
VOLTAGE 240 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 2 —
FRAME D71 —
SPEED / SYNCHRONOUS 3000 (rpm) —
SPEED / FULL LOAD 2870 (rpm) —
CURRENT / FULL LOAD 2.66 (Amps) —
CURRENT / LOCKED ROTOR 490 % —
TORQUE / FULL LOAD TORQUE 1.27 (Nm) —
TORQUE / STARTING TORQUE 230 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 230 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 72.4 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 80 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING Not stated (blank in source) —
WEIGHT OF MOTOR 6202 ZZ kgs —
BEARINGS / DRIVE END 6202 ZZ —
BEARINGS / NON DRIVE END 6202 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

Datasheet-517.pdf

The source prints a bearing code in WEIGHT OF MOTOR. This is not a usable mass. The original entry remains below for traceability; catalogue approximate masses are separately labelled.

Associated selection rows: 406

Datasheet-517.pdf.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BEGY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 0.37 —
VOLTAGE 240 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 4 —
FRAME D71 —
SPEED / SYNCHRONOUS 1500 (rpm) —
SPEED / FULL LOAD 1415 (rpm) —
CURRENT / FULL LOAD 2.9 (Amps) —
CURRENT / LOCKED ROTOR 520 % —
TORQUE / FULL LOAD TORQUE 2.45 (Nm) —
TORQUE / STARTING TORQUE 220 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 230 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 68.7 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 78 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING Not stated (blank in source) —
WEIGHT OF MOTOR 6202 ZZ kgs —
BEARINGS / DRIVE END 6202 ZZ —
BEARINGS / NON DRIVE END 6202 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

Datasheet-512.pdf

The source prints a bearing code in WEIGHT OF MOTOR. This is not a usable mass. The original entry remains below for traceability; catalogue approximate masses are separately labelled.

Associated selection rows: 407

Datasheet-512.pdf.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BEGY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 0.55 —
VOLTAGE 240 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 2 —
FRAME D71 —
SPEED / SYNCHRONOUS 3000 (rpm) —
SPEED / FULL LOAD 2865 (rpm) —
CURRENT / FULL LOAD 3.74 (Amps) —
CURRENT / LOCKED ROTOR 590 % —
TORQUE / FULL LOAD TORQUE 1.86 (Nm) —
TORQUE / STARTING TORQUE 270 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 240 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 73 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 86 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING Not stated (blank in source) —
WEIGHT OF MOTOR 6202 ZZ kgs —
BEARINGS / DRIVE END 6202 ZZ —
BEARINGS / NON DRIVE END 6202 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

0.75BE2 , 0.55BE4 , 0.75BE4.pdf

Associated selection rows: 408, 409, 410, 411

PDFdrawings-519.zip > 80 FRAME/0.75BE2 , 0.55BE4 , 0.75BE4.pdf.

Source page 1

Conditions for this section:

  • C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / frame_as_printed D80 as printed —
Drawing / Phase 1 as printed C1
Drawing / Construction Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor as printed C1
Drawing note / 1 Foot mounted IM1001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 For belt or direct drive. as printed —

Printed rating table — P049, 0.75BE2 , 0.55BE4 , 0.75BE4.pdf, page 1

Conditions for this section:

  • C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 0.75 kW 1 HP 3000 rpm (synchronous, as headed) C1
2 4 poles 0.55/0.75 kW 0.75/1 HP 1500 rpm (synchronous, as headed) C1

Dimensions read from this original outline

Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.

Drawing callout Printed value
Transverse mounting-hole centres 125
Foot overall width 165
Foot slot-group width callout 40
Foot thickness 3.2
Shaft height and tolerance 80 +0/−0.5
Lower terminal enclosure height above foot plane 40
Axial mounting-hole centres 100
Foot overall axial length 130
Cable-entry diameter Ø22
Shaft diameter and fit Ø19 j6
Key width 6
Shaft keyseat lower-height callout 15.5
Shaft-and-key top height 21.5
Shaft-end thread and depth M6 TAP DEEP 9
Foot slot detail: length × width 20 × 10
Shaft extension 40
Key length callout 25
Overall axial length 307
Shaft-centre to terminal enclosure outer edge 122
Shaft-centre to cable-entry axis 94
Front-view body width callout 163
Front-view overall vertical envelope 205
Shaft shoulder to nearer foot-hole centre 50
Rear foot-hole centre to fan end 117
Upper axial callout from fan end to drawn reference 123

0.75BF2 , 0.55BF4.pdf

Associated selection rows: 408, 409, 410, 411

PDFdrawings-519.zip > 80 FRAME/0.75BF2 , 0.55BF4.pdf.

Source page 1

Conditions for this section:

  • C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / frame_as_printed D80 as printed —
Drawing / Phase 1 as printed C1
Drawing / Construction Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor as printed C1
Drawing note / 1 Foot & flange mounted IM2001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 For belt or direct drive. as printed —

Printed rating table — P049, 0.75BF2 , 0.55BF4.pdf, page 1

Conditions for this section:

  • C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 0.75 kW 1 HP 3000 rpm (synchronous, as headed) C1
2 4 poles 0.55 kW 0.75 HP 1500 rpm (synchronous, as headed) C1

TECO Single Phase Steel Frame – BEGY — technical configurations, part 2 of 2

Product: P049. Product page: https://electricmotors.teco.com.au/product/teco-single-phase-steel-frame-motors/

Dimensions read from this original outline

Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.

Drawing callout Printed value
Transverse mounting-hole centres 125
Foot overall width 165
Foot slot-group width callout 40
Foot thickness 3.2
Shaft height and tolerance 80 +0/−0.5
Lower terminal enclosure height above foot plane 40
Axial mounting-hole centres 100
Foot overall axial length 130
Cable-entry diameter Ø22
Shaft diameter and fit Ø19 j6
Key width 6
Shaft keyseat lower-height callout 15.5
Shaft-and-key top height 21.5
Shaft-end thread and depth M6 TAP DEEP 9
Foot slot detail: length × width 20 × 10
Shaft extension 40
Key length callout 25
Flange bolt pitch-circle diameter Ø165
Flange pilot diameter and fit Ø130 h7
Flange outer diameter Ø200
Flange bolt holes 4-Ø12 Holes
Flange thickness 12
Flange register projection 3.5
Overall axial length 335
Shaft-centre to terminal enclosure outer edge 122
Shaft-centre to cable-entry axis 94
Front-view overall vertical envelope 205
Axial front mounting offset as drawn 77.5
Rear foot-hole centre to fan end 148
Upper axial callout from fan end to drawn reference 123
Axial foot slot-group callout 30

0.75BF4.pdf

Associated selection rows: 408, 409, 410, 411

PDFdrawings-519.zip > 80 FRAME/0.75BF4.pdf.

Source page 1

Conditions for this section:

  • C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / frame_as_printed D80 as printed —
Drawing / Phase 1 as printed C1
Drawing / Construction Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor as printed C1
Drawing note / 1 Foot & flange mounted IM2001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 For belt or direct drive. as printed —

Printed rating table — P049, 0.75BF4.pdf, page 1

Conditions for this section:

  • C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 4 poles 0.75 kW 1 HP 1500 rpm (synchronous, as headed) C1

Dimensions read from this original outline

Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.

Drawing callout Printed value
Transverse mounting-hole centres 125
Foot overall width 165
Foot slot-group width callout 40
Foot thickness 3.2
Shaft height and tolerance 80 +0/−0.5
Lower terminal enclosure height above foot plane 40
Axial mounting-hole centres 100
Foot overall axial length 130
Cable-entry diameter Ø22
Shaft diameter and fit Ø19 j6
Key width 6
Shaft keyseat lower-height callout 15.5
Shaft-and-key top height 21.5
Shaft-end thread and depth M6 TAP DEEP 9
Foot slot detail: length × width 20 × 10
Shaft extension 40
Key length callout 25
Flange bolt pitch-circle diameter Ø165
Flange pilot diameter and fit Ø130 h7
Flange outer diameter Ø200
Flange bolt holes 4-Ø12 Holes
Flange thickness 12
Flange register projection 3.5
Overall axial length 355
Shaft-centre to terminal enclosure outer edge 122
Shaft-centre to cable-entry axis 94
Front-view overall vertical envelope 205
Axial front mounting offset as drawn 77.5
Rear foot-hole centre to fan end 138
Upper axial callout from fan end to drawn reference 143
Axial foot slot-group callout 30

0.75BV4.pdf

Associated selection rows: 408, 409, 410, 411

PDFdrawings-519.zip > 80 FRAME/0.75BV4.pdf.

Source page 1

Conditions for this section:

  • C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / frame_as_printed D80 as printed —
Drawing / Phase 1 as printed C1
Drawing / Construction Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor as printed C1
Drawing note / 1 Flange mounted IM3001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 For belt or direct drive. as printed —

Printed rating table — P049, 0.75BV4.pdf, page 1

Conditions for this section:

  • C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 4 poles 0.75 kW 1 HP 1500 rpm (synchronous, as headed) C1

Dimensions read from this original outline

Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.

Drawing callout Printed value
Cable-entry diameter Ø22
Shaft diameter and fit Ø19 j6
Key width 6
Shaft keyseat lower-height callout 15.5
Shaft-and-key top height 21.5
Shaft-end thread and depth M6 TAP DEEP 9
Shaft extension 40
Key length callout 25
Flange bolt pitch-circle diameter Ø165
Flange pilot diameter and fit Ø130 h7
Flange outer diameter Ø200
Flange bolt holes 4-Ø12 Holes
Flange thickness 12
Flange register projection 3
Flange-hole angular offset 45
Overall axial length 335
Flange face to fan end 295
Shaft-centre to terminal enclosure outer edge 122
Shaft-centre to cable-entry axis 94
Front-view overall vertical envelope 225

0.75VB2 , 0.55BV4.pdf

Associated selection rows: 408, 409, 410, 411

PDFdrawings-519.zip > 80 FRAME/0.75VB2 , 0.55BV4.pdf.

Source page 1

Conditions for this section:

  • C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / frame_as_printed D80 as printed —
Drawing / Phase 1 as printed C1
Drawing / Construction Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor as printed C1
Drawing note / 1 Flange mounted IM3001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 For belt or direct drive. as printed —

Printed rating table — P049, 0.75VB2 , 0.55BV4.pdf, page 1

Conditions for this section:

  • C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 0.75 kW 1 HP 3000 rpm (synchronous, as headed) C1
2 4 poles 0.55 kW 0.75 HP 1500 rpm (synchronous, as headed) C1

Dimensions read from this original outline

Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.

Drawing callout Printed value
Cable-entry diameter Ø22
Shaft diameter and fit Ø19 j6
Key width 6
Shaft keyseat lower-height callout 15.5
Shaft-and-key top height 21.5
Shaft-end thread and depth M6 TAP DEEP 9
Shaft extension 40
Key length callout 25
Flange bolt pitch-circle diameter Ø165
Flange pilot diameter and fit Ø130 h7
Flange outer diameter Ø200
Flange bolt holes 4-Ø12 Holes
Flange thickness 12
Flange register projection 3
Flange-hole angular offset 45
Overall axial length 325
Flange face to fan end 285
Shaft-centre to terminal enclosure outer edge 122
Shaft-centre to cable-entry axis 94
Front-view overall vertical envelope 225

1.1BE2.pdf

Associated selection rows: 408, 409, 410, 411

PDFdrawings-519.zip > 80 FRAME/1.1BE2.pdf.

Source page 1

Conditions for this section:

  • C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / frame_as_printed D80 as printed —
Drawing / Phase 1 as printed C1
Drawing / Construction Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor as printed C1
Drawing note / 1 Foot mounted IM1001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 For belt or direct drive. as printed —

Printed rating table — P049, 1.1BE2.pdf, page 1

Conditions for this section:

  • C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 1.1 kW 1.5 HP 3000 rpm (synchronous, as headed) C1

Dimensions read from this original outline

Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.

Drawing callout Printed value
Transverse mounting-hole centres 125
Foot overall width 165
Foot slot-group width callout 40
Foot thickness 3.2
Shaft height and tolerance 80 +0/−0.5
Lower terminal enclosure height above foot plane 40
Axial mounting-hole centres 100
Foot overall axial length 130
Cable-entry diameter Ø22
Shaft diameter and fit Ø19 j6
Key width 6
Shaft keyseat lower-height callout 15.5
Shaft-and-key top height 21.5
Shaft-end thread and depth M6 TAP DEEP 9
Foot slot detail: length × width 20 × 10
Shaft extension 40
Key length callout 25
Overall axial length 307
Shaft-centre to terminal enclosure outer edge 122
Shaft-centre to cable-entry axis 94
Front-view body width callout 163
Front-view overall vertical envelope 211
Shaft shoulder to nearer foot-hole centre 50
Rear foot-hole centre to fan end 117
Upper axial callout from fan end to drawn reference 123

1.1BF2.pdf

Associated selection rows: 408, 409, 410, 411

PDFdrawings-519.zip > 80 FRAME/1.1BF2.pdf.

Source page 1

Conditions for this section:

  • C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / frame_as_printed D80 as printed —
Drawing / Phase 1 as printed C1
Drawing / Construction Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor as printed C1
Drawing note / 1 Foot & flange mounted IM2001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 For belt or direct drive. as printed —

Printed rating table — P049, 1.1BF2.pdf, page 1

Conditions for this section:

  • C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 1.1 kW 1.5 HP 3000 rpm (synchronous, as headed) C1

Dimensions read from this original outline

Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.

Drawing callout Printed value
Transverse mounting-hole centres 125
Foot overall width 165
Foot slot-group width callout 40
Foot thickness 3.2
Shaft height and tolerance 80 +0/−0.5
Lower terminal enclosure height above foot plane 40
Axial mounting-hole centres 100
Foot overall axial length 130
Cable-entry diameter Ø22
Shaft diameter and fit Ø19 j6
Key width 6
Shaft keyseat lower-height callout 15.5
Shaft-and-key top height 21.5
Shaft-end thread and depth M6 TAP DEEP 9
Foot slot detail: length × width 20 × 10
Shaft extension 40
Key length callout 25
Flange bolt pitch-circle diameter Ø165
Flange pilot diameter and fit Ø130 h7
Flange outer diameter Ø200
Flange bolt holes 4-Ø12 Holes
Flange thickness 12
Flange register projection 3.5
Overall axial length 355
Shaft-centre to terminal enclosure outer edge 122
Shaft-centre to cable-entry axis 94
Front-view overall vertical envelope 211
Axial front mounting offset as drawn 77.5
Rear foot-hole centre to fan end 138
Upper axial callout from fan end to drawn reference 143
Axial foot slot-group callout 30

1.1BV2.pdf

Associated selection rows: 408, 409, 410, 411

PDFdrawings-519.zip > 80 FRAME/1.1BV2.pdf.

Source page 1

Conditions for this section:

  • C1: Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / frame_as_printed D80 as printed —
Drawing / Phase 1 as printed C1
Drawing / Construction Totally enclosed fan cooled capacitor-start & run type; squirrel-cage rotor as printed C1
Drawing note / 1 Flange mounted IM3001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 For belt or direct drive. as printed —

Printed rating table — P049, 1.1BV2.pdf, page 1

Conditions for this section:

  • C1: Blank or dotted entries mean not stated, never zero. Slash-separated values are alternatives within the printed row; do not combine unrelated rows. Source-specific ratings. Use the original drawing for diagram-only dimensions, fits, tolerances and geometry. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 1.1 kW 1.5 HP 3000 rpm (synchronous, as headed) C1

Dimensions read from this original outline

Drawing does not explicitly state general dimensional units; retain printed values. Angle is in degrees. Typical dimensions only; refer to TECO for certified dimensions. Geometry and datum positions remain in the linked original.

Drawing callout Printed value
Cable-entry diameter Ø22
Shaft diameter and fit Ø19 j6
Key width 6
Shaft keyseat lower-height callout 15.5
Shaft-and-key top height 21.5
Shaft-end thread and depth M6 TAP DEEP 9
Shaft extension 40
Key length callout 25
Flange bolt pitch-circle diameter Ø165
Flange pilot diameter and fit Ø130 h7
Flange outer diameter Ø200
Flange bolt holes 4-Ø12 Holes
Flange thickness 12
Flange register projection 3
Flange-hole angular offset 45
Overall axial length 335
Flange face to fan end 295
Shaft-centre to terminal enclosure outer edge 122
Shaft-centre to cable-entry axis 94
Front-view overall vertical envelope 231

Datasheet-518.pdf

The source prints a bearing code in WEIGHT OF MOTOR. This is not a usable mass. The original entry remains below for traceability; catalogue approximate masses are separately labelled.

Associated selection rows: 408

Datasheet-518.pdf.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BEGY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 0.55 —
VOLTAGE 240 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 4 —
FRAME D80 —
SPEED / SYNCHRONOUS 1500 (rpm) —
SPEED / FULL LOAD 1425 (rpm) —
CURRENT / FULL LOAD 4.3 (Amps) —
CURRENT / LOCKED ROTOR 510 % —
TORQUE / FULL LOAD TORQUE 3.7 (Nm) —
TORQUE / STARTING TORQUE 260 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 180 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 70.1 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 77 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING Not stated (blank in source) —
WEIGHT OF MOTOR 6204 ZZ kgs —
BEARINGS / DRIVE END 6204 ZZ —
BEARINGS / NON DRIVE END 6202 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

Datasheet-513.pdf

The source prints a bearing code in WEIGHT OF MOTOR. This is not a usable mass. The original entry remains below for traceability; catalogue approximate masses are separately labelled.

Associated selection rows: 409

Datasheet-513.pdf.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BEGY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 0.75 —
VOLTAGE 240 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 2 —
FRAME D80 —
SPEED / SYNCHRONOUS 3000 (rpm) —
SPEED / FULL LOAD 2900 (rpm) —
CURRENT / FULL LOAD 4.84 (Amps) —
CURRENT / LOCKED ROTOR 700 % —
TORQUE / FULL LOAD TORQUE 2.45 (Nm) —
TORQUE / STARTING TORQUE 320 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 280 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 74 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 87 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING Not stated (blank in source) —
WEIGHT OF MOTOR 6204 ZZ kgs —
BEARINGS / DRIVE END 6204 ZZ —
BEARINGS / NON DRIVE END 6202 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

Datasheet-519.pdf

The source prints a bearing code in WEIGHT OF MOTOR. This is not a usable mass. The original entry remains below for traceability; catalogue approximate masses are separately labelled.

Associated selection rows: 410

Datasheet-519.pdf.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BEGY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 0.75 —
VOLTAGE 240 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 4 —
FRAME D80 —
SPEED / SYNCHRONOUS 1500 (rpm) —
SPEED / FULL LOAD 1425 (rpm) —
CURRENT / FULL LOAD 5 (Amps) —
CURRENT / LOCKED ROTOR 580 % —
TORQUE / FULL LOAD TORQUE 5 (Nm) —
TORQUE / STARTING TORQUE 250 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 220 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 72.1 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 86 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING Not stated (blank in source) —
WEIGHT OF MOTOR 6204 ZZ kgs —
BEARINGS / DRIVE END 6204 ZZ —
BEARINGS / NON DRIVE END 6202 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

Datasheet-514.pdf

The source prints a bearing code in WEIGHT OF MOTOR. This is not a usable mass. The original entry remains below for traceability; catalogue approximate masses are separately labelled.

Associated selection rows: 411

Datasheet-514.pdf.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BEGY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 1.1 —
VOLTAGE 240 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 2 —
FRAME D80 —
SPEED / SYNCHRONOUS 3000 (rpm) —
SPEED / FULL LOAD 2880 (rpm) —
CURRENT / FULL LOAD 6.6 (Amps) —
CURRENT / LOCKED ROTOR 650 % —
TORQUE / FULL LOAD TORQUE 3.6 (Nm) —
TORQUE / STARTING TORQUE 240 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 250 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 75.5 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 94 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING Not stated (blank in source) —
WEIGHT OF MOTOR 6204 ZZ kgs —
BEARINGS / DRIVE END 6204 ZZ —
BEARINGS / NON DRIVE END 6202 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

Datasheet-515.pdf

Associated selection rows: 412

Datasheet-515.pdf.

Source differences and limitations

  • Website/source difference — FRAME: website D63; PDF page 1 D71. Website row IDs: 412. Neither is automatically substituted for the other.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BEGY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 0.18 —
VOLTAGE 240 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 4 —
FRAME D71 —
SPEED / SYNCHRONOUS 1500 (rpm) —
SPEED / FULL LOAD 1430 (rpm) —
CURRENT / FULL LOAD 1.7 (Amps) —
CURRENT / LOCKED ROTOR 470 % —
TORQUE / FULL LOAD TORQUE 1.18 (Nm) —
TORQUE / STARTING TORQUE 270 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 240 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 63.5 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 72 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING Not stated (blank in source) —
WEIGHT OF MOTOR 7.5 kgs —
BEARINGS / DRIVE END 6201ZZ —
BEARINGS / NON DRIVE END 6201 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

Downloads, customisation and support

Download our single-phase catalogue. Individual datasheets, PDF archives and CAD downloads are linked with the selections above. We can help with mounting options, terminal-box arrangements, 3D files and certified dimensions.

No separate operating manual is attached in the collected BEGY product pack. Contact our team for the installation instructions and modifications relevant to your motor. Historical catalogue contact details are replaced here by our current contact-page link.

Company documents

These company references have their own scope; they are not motor-specific approvals.

Source editions: TECO1PH-032014 catalogue and individual configuration sheets collected 15 October 2026. Product-page wording checked 27 October 2026. Source differences and original document identities remain traceable.