Product

Product Facts

Product Name
TECO Single Phase Cast Iron Frame - BECY - TECO Electric Motors Australia and New Zealand
Category
Industrial & Commercial Equipment > Electric Motors

TECO · SINGLE-PHASE MOTORS

BECY Single Phase Cast Iron Motors

Dependable single-phase power, with the strength of a cast-iron frame. Our BECY range covers 1.1–7.5 kW, with metric frames 90S–132M, good starting torque and a choice of foot, flange, or foot-and-flange mounting. We can help you match the motor and its options to your application.

Our motors combine capacitor start–capacitor run (CSR) operation, continuous S1 duty, IP44 protection and totally enclosed fan cooling (IC411). Cast-iron construction, a steel terminal/capacitor box and steel fan cover provide a robust package. We use Class H and F insulation materials with low temperature rise for thermal reserve; the catalogue's insulation-class specification is Class F. Our published product offer includes a two-year warranty—please confirm the terms for your purchase with our team.

Supply and protection: motors below 1.5 kW are described as 240 V, single-phase, 50 Hz with manual overload protection. Motors from 1.5 kW are described as 240/480 V, single-phase, 50 Hz. The selection table lists 240 V throughout; the individual datasheets retain their own voltage and paired-current ratings below.

Choose your BECY configuration

Our 13 listed selections are linked below to their individual datasheets and every collected PDF drawing member. We show each distinct source once, even when several selections share it. Match the power, pole count, frame and mounting printed on the source; a shared archive does not make every member interchangeable.

The drawing references include IM1001 foot, IM2001 foot and flange, and IM3001 flange arrangements. In our catalogue, the flange-only range uses the BEDY designation; that name is retained in its tables. The 7.5 kW two-pole selection links to a standalone foot drawing, while other selections link to archives with several mountings. Related archive drawings remain associated with their original rows.

RowWebsite specificationDatasheetDrawings / archive members
413kW Rating: 1.50; Voltage: 240; Phases: 1; No. of Poles: 4; Frame Size: D90LDatasheet-495.pdf2.2BE2 , 1.5BE4.pdf
2.2BF2 , 1.5BF4.pdf
2.2BV2 , 1.5VB4.pdf
414kW Rating: 2.20; Voltage: 240; Phases: 1; No. of Poles: 2; Frame Size: D90LDatasheet-489.pdf2.2BE2 , 1.5BE4.pdf
2.2BF2 , 1.5BF4.pdf
2.2BV2 , 1.5VB4.pdf
415kW Rating: 1.10; Voltage: 240; Phases: 1; No. of Poles: 4; Frame Size: D90SDatasheet-494.pdf1.5BE2 , 1.1BE4.pdf
1.5BF2 , 1.1BF4.pdf
1.5BV2 , 1.1BV4.pdf
416kW Rating: 1.50; Voltage: 240; Phases: 1; No. of Poles: 2; Frame Size: D90SDatasheet-488.pdf1.5BE2 , 1.1BE4.pdf
1.5BF2 , 1.1BF4.pdf
1.5BV2 , 1.1BV4.pdf
417kW Rating: 2.20; Voltage: 240; Phases: 1; No. of Poles: 4; Frame Size: D100LDatasheet-496.pdf3BE2 , 2.2BE4 , 3BE4.pdf
3BF2 , 2.2BF4 , 3BF4.pdf
3BV2 , 2.2BV4 , 3BV4.pdf
418kW Rating: 3.00; Voltage: 240; Phases: 1; No. of Poles: 2; Frame Size: D100LDatasheet-490.pdf3BE2 , 2.2BE4 , 3BE4.pdf
3BF2 , 2.2BF4 , 3BF4.pdf
3BV2 , 2.2BV4 , 3BV4.pdf
419kW Rating: 3.00; Voltage: 240; Phases: 1; No. of Poles: 4; Frame Size: D100LDatasheet-497.pdf3BE2 , 2.2BE4 , 3BE4.pdf
3BF2 , 2.2BF4 , 3BF4.pdf
3BV2 , 2.2BV4 , 3BV4.pdf
420kW Rating: 4.00; Voltage: 240; Phases: 1; No. of Poles: 2; Frame Size: D112MDatasheet-491.pdf4BE2 , 4BE4.pdf
4BF2 , 4BF4.pdf
4BV2 , 4BV4.pdf
421kW Rating: 4.00; Voltage: 240; Phases: 1; No. of Poles: 4; Frame Size: D112MDatasheet-498.pdf4BE2 , 4BE4.pdf
4BF2 , 4BF4.pdf
4BV2 , 4BV4.pdf
422kW Rating: 7.50; Voltage: 240; Phases: 1; No. of Poles: 2; Frame Size: D132MDatasheet-493.pdf5.5BE2-7.5BE2-5.5BE4.pdf
423kW Rating: 7.50; Voltage: 240; Phases: 1; No. of Poles: 4; Frame Size: D132MDatasheet-500.pdf7.5BE4.pdf
7.5BF4.pdf
7.5BV4.pdf
424kW Rating: 5.50; Voltage: 240; Phases: 1; No. of Poles: 2; Frame Size: D132SDatasheet-492.pdf5.5BE2 , 7.5BE2 , 5.5BE4.pdf
5.5BF2 , 7.5BF2 , 5.5BF4.pdf
5.5BV2 , 7.5BV2 , 5.5BV4.pdf
425kW Rating: 5.50; Voltage: 240; Phases: 1; No. of Poles: 4; Frame Size: D132SDatasheet-499.pdf5.5BE2 , 7.5BE2 , 5.5BE4.pdf
5.5BF2 , 7.5BF2 , 5.5BF4.pdf
5.5BV2 , 7.5BV2 , 5.5BV4.pdf

CAD downloads: CADdrawings-495.zip · CADdrawings-494.zip · CADdrawings-497.zip · CADdrawings-498.zip · CADdrawings-500.zip · CADdrawings-499.zip

All 13 3D-drawing fields are available upon request. These are availability notices, not downloaded models. No software download is listed on this product page.

Built around your application

Tell us about your load's starting and running torque, operating duty, available supply and mounting requirements. Our CSR motors use a start capacitor for starting torque and a run capacitor during operation. The catalogue describes high starting torque with good running performance; the exact current, torque, speed, efficiency and power factor remain specific to the selected motor.

Our catalogue describes continuous operation at nameplate current, an ambient range of −10 to 40°C, and operation below 1,000 m altitude, with derating required above those conditions. Its standard specification gives a non-hazardous environment, maximum 90% relative humidity, and belt or direct drive. It lists IEC 34 and AS1359/1360 references; our product page names IEC60034 and AS1359. These source statements are not a current certificate of approval.

The cast-iron frame and endshields, cooling fins, bidirectional polypropylene fan, double-shielded pre-packed bearings and dynamically balanced die-cast aluminium rotor support dependable operation. The catalogue describes a centrifugal switch, copper random-wound stator, phenolic-base primer and synthetic enamel finish. For frames 90–132, its standard specification lists a grey Munsell N5.0-SG finish and stainless-steel nameplate. The terminal box is shown on the right viewed from the drive shaft end, with a left-side option. Confirm any modification with us.

We offer foot, flange and combined mounting options. Use each mounting's own dimensions and tolerances; do not transfer a foot dimension to a flange version. The outlines are marked typical dimensions only—contact us for certified dimensions before final installation. The catalogue states millimetres, while the individual outline sheets do not explicitly state general dimensional units. Their values remain as printed. Synchronous speed and full-load speed are separately identified.

For rotation changes and terminal connections, use the original diagrams and the instructions for your motor. The catalogue separates motors up to 1.1 kW with thermal protection from 1.5 kW and above without thermal protection in its wiring diagrams. Its spare-parts schedule nevertheless lists thermal-overload part codes for the 1.5 kW rows. Ask us to confirm the fitted protection and wiring; do not infer it from a spare-parts entry alone.

Details to confirm with our team

We retain the source-specific information below wherever our published documents differ. Please confirm the applicable edition and configuration with us before selecting replacement components or fixing installation dimensions.

Selection / sheetFieldDatasheetCatalogue
2.2 kW / 2P · Datasheet-489.pdfFull-load current at 480 V6.55 A6.6 A
7.5 kW / 2P · Datasheet-493.pdfFrame designationD132M 132S

Catalogue current/torque ratios and power factors were compared on the same percentage basis as the datasheets. Original ratios, supply pairs and frame labels remain unchanged below. The 6.55/6.6 A difference may reflect rounding; neither figure is substituted.

BECY catalogue specifications

Our single-phase catalogue covers several families. Below we retain shared operating and construction context, the BECY performance and spare-parts rows, and the cast-iron mounting schedules—including flange-only tables labelled BEDY. BEGY steel-frame and B56-only tables are excluded from this product guide. Every catalogue page remains linked to its original edition.

Catalogue page 1 — Cover and whole-catalogue range; BECY range stated in guide.

Catalogue range and navigation

Catalogue page 2

Catalogue context / Range

Property Value Unit
BECY Single Phase Motor, Type CSR; Series BECY; Frame size 90–132; Output 1.1–7.5kW.

Catalogue context

Property Value Unit
Contents Motor range p2; standard specification p3; general description p4; motor classification and selection p5; connection diagram p5; schematic drawings p6; terminal connection p6; performance data p7; dimension drawings IM1001 p8, IM3001 p9, IM2001 p10, B56 p11; spare parts p11; company addresses p12.

Shared standard specification

Catalogue page 3

Shared catalogue reference: this page also names other frame sizes, outputs, supplies and mountings. Those entries are not blanket BECY specifications. Use the selected BECY source and confirm any conflicting limits.

Ratings and specifications / Rating

Property Value Unit
Voltage Rated Voltage 240V/480V
Frequency Rated Frequency 50Hz
Output range 0.18kW – 7.5kW
R.P.M. (Syn.) 3000R.P.M. (2 Pole); 1500R.P.M. (4 Pole)
Duty S1 (Continuous)
Frame size 71 – 132M
Enclosure TEFC Totally Enclosed Fan Cooled
Degree of protection IP 44 (Totally Enclosed, Splash Proof)
Method of cooling IC 0141 External Fan. Surface Cooling
Mounting IM 1001 Foot Mounting; IM 3001 Flange Mounting; IM 2001 Foot & Flange Mounting

Ratings and specifications / Application

Property Value Unit
Power condition Voltage ±10%, Frequency ±5%.
Environment conditions Area = Non Hazardous. Ambient Temperature −10°C to 40°C. Relative Humidity = Max. 90%. Altitude = Max. 1000m (3300ft).
Drive method Belt Drive or Direct Coupling
Direction of rotation Bi-Directional
Method of starting D.O.L. (Direct-On-Line) Full Voltage

Ratings and specifications / Construction

Property Value Unit
Frame 71 – 80 Rolled Steel; 90 – 132 Cast Iron
Endshield 71 – 80 Alum. Alloy with Steel Insert, except Frame 80 DE (Cast Iron); 90 – 132 Cast Iron
External fan Polypropylene
Fan cover Pressed Steel
Bearing Single Row Deep Groove Ball Bearing – Double Shields, Pre-Greased
Terminal box Pressed Steel, with Clearance Hole Cable Entry
Stator winding Polyester Enamelled Copper Wires, Random Wound
Insulation system Class F (Operating Temp. 155°C – Temp. Rise 105°C)
Rotor Squirrel Cage. Alum. Conductor with End-Ring
Painting Phenolic Base Paint, Laquer Surface Finish; 71 – 80 Munsell 2.5G 6/3 (Deep Green); 90 – 132 Munsell N5.0 – SG (Grey)
Name plate 71 – 80 Aluminium; 90 – 132 Stainless Steel
Bolts ISO Metric System (Except B56)

Ratings and specifications / Performance

Property Value Unit
Temperature rise Not Exceeding 90°C by Resistance Method
Over speed 125% Syn. R.P.M. for one min.
Over torque 160% Rated Torque for 15 sec.
Capacitor start Series BEGY/BETY and BECY/BEDY: Capacitor Start – Capacitor Run. Series B56: Cap. Start – Cap. Run and Cap. Start – Induction Run.
Standards Comply with relevant IEC & AS Standards

Ratings, construction and options

Catalogue page 4

Shared catalogue reference: this page also names other frame sizes, outputs, supplies and mountings. Those entries are not blanket BECY specifications. Use the selected BECY source and confirm any conflicting limits.

Catalogue context

Property Value Unit
Connection 240 Volts Single Phase 50Hz for motors of 0.18kW to 7.5kW. 240/480 Volts Single Phase 50Hz from 1.5 to 7.5kW. The motors will produce their rated performance with voltage +/−5 per cent.
Rating Continuously rated at name plate current defined as S1 to AS 1359 within an ambient temperature −10 to 40°C, and altitude below 1000 metres. For higher ambients and/or altitudes the output rating must be adjusted accordingly; contact TECO.
Performance Standard motors are designed with performance in accordance with relevant standards within IEC34 and AS 1359 & 1360.
Direction of rotation Suitable for operation in either direction. Reversing direction uses the connection link within the terminal box; source refers to page 6. Original diagrams remain the authority.
Mounting Foot: IM1001, 1011, 1031, 1051, 1061, 1071. Flange: IM3001, 3011, 3031. Foot and Flange: IM2001. According to AS 1359 and IEC72.
Frame Two pole motors up to 1.1kW, four pole motors up to 0.75kW and Series B56 motors are rolled steel. Larger motors are high-grade cast iron with longitudinal cooling fins and integrally cast feet.
Fan and fan cowl Bi-directional cooling fans of polypropylene; pressed-steel fan cowl painted internally and externally to resist corrosion.
Bearings and lubrication Double shielded, pre-packed ball bearings sealed against dust and moisture; source states no further attention for the life of the bearing.
Stator winding and insulation High-grade insulated cold-rolled electromagnetic steel laminations; Class F insulation system. Source states resistance to tropical and high-humidity conditions. All motors incorporate a centrifugal switch between the starting and running windings.
Rotor assembly One-piece pressure die-cast aluminium rotor conductors and end rings; rotating parts dynamically balanced to minimise vibration.
Terminal box Pressed steel terminal box at the right-hand side when looking at the drive shaft end; left-hand side optional. Connections shown on source page 6.
Capacitors BEGY 0.25–1.1kW (2P) and BECY 1.1kW (4P) to 7.5kW are capacitor start capacitor run. B56 0.75kW 2-pole and 0.25–0.55kW 4-pole are capacitor start induction run; B56 0.75kW 4-pole is capacitor start capacitor run.
Paint finish Castings and steel parts have a phenolic-base prime coat and synthetic enamel paint finish.

Starting arrangements and selection

Catalogue page 5

Shared catalogue reference: this page also names other frame sizes, outputs, supplies and mountings. Those entries are not blanket BECY specifications. Use the selected BECY source and confirm any conflicting limits.

Catalogue context

Property Value Unit
Classification CSIR = Capacitor Start – Induction Run. CSR = Capacitor Start – Capacitor Run.
Selection Selection depends on starting and running torque requirements, duty cycle and power-supply starting/running current limits. Source says TECO can manufacture single-phase motors for various applications.
CSIR characteristics High starting torque and medium starting current; source describes suitability for heavier duty applications and power supplies with higher voltage variation.
CSR characteristics Combines high starting torque and good running performance. Source describes use for integral-rating applications with heavier starting torque requirements.
Source stock and protector note Source states CSIR and CSR motors are stocked by TECO Australia, and single-voltage motors are normally fitted with thermal protectors. Historical catalogue statement; not current inventory proof.
Connection diagram context Separate C.C.W. and C.W. rotation diagrams for CSIR at 240V and CSR at 240V/480V. No wiring connections reconstructed; consult original page.

Terminal connection reference

Catalogue page 6

Shared catalogue reference: this page also names other frame sizes, outputs, supplies and mountings. Those entries are not blanket BECY specifications. Use the selected BECY source and confirm any conflicting limits.

Catalogue context

Property Value Unit
Terminal connection context Printed groups: 1.1kW and below with Thermal Protector (240V), and 1.5kW and above without Thermal Protector (240V/480V); C.C.W. and C.W. diagrams. Original diagrams govern connections; geometry is not encoded here.

Schematic legend / Frame 90–132

Property Value Unit
1 Fan Cover part label
2 Fan part label
3 Centrifugal Switch part label
4 Centr. Switch Cover part label
5 Endshield N-End part label
6 Stator Frame part label
7 Eye Bolt (100-132) part label
8 Stator part label
9 Rotor part label
10 Endshield N-End part label
11 Bearing part label
12 Shaft part label
13 Terminal Box part label

BECY performance data

Catalogue page 7

Performance data

Conditions: Four printed row groups: main-range 2-pole, main-range 4-pole, B56 2-pole, B56 4-pole. A dash is preserved as a source dash, not zero. Only the listed frame/output/pole combination is covered; source association with a product does not make all rows applicable to that product. 240/480V supply distinctions and start/run capacitors remain separate. Notes/formulas are retained in the page commentary.

Poles (poles) Rated output (kW) Frame size Speed (RPM) Efficiency (%) Power factor cosφ (dimensionless) Full-load current 240V (A) Full-load current 480V (A) Starting current ratio 240V (Ist/IN) Starting current ratio 480V (Ist/IN) Full-load torque (Nm) Starting torque ratio (Tst/TN) Breakdown torque ratio (Tb/TN) Start capacitor (µF) Start capacitor rated voltage (Vac) Run capacitor (µF) Run capacitor rated voltage (Vac)
2 1.5 90S 2910 77.5 0.89 9 4.5 7 7 4.9 2.3 2.6 125 250 15 440
2 2.2 90L 2895 77.9 0.92 13.1 6.6 6.7 6.7 7.3 2.1 2.5 150 250 20 440
2 3 100L 2875 75.6 0.92 18 9 5.9 5.9 10 2.5 2.3 250 250 30 440
2 4 112M 2900 74.6 0.93 25 12.5 5.5 5.5 13.1 1.6 2.2 300 250 30 440
2 5.5 132S 2930 79.2 0.96 30 15 8 8 18 2.8 2.6 560 330 60 440
2 7.5 132S 2930 81.2 0.99 40 20 6.8 6.8 24.5 2.4 2.3 720 330 100 440
4 1.1 90S 1445 69.6 0.76 8.8 — 5.1 — 7.3 2.2 2.2 125 250 15 440
4 1.5 90L 1450 72.8 0.82 10.4 5.2 5.8 5.8 9.9 2.4 2.2 150 250 15 440
4 2.2 100L 1455 76.4 0.92 13.3 6.7 5.7 5.7 14.4 1.8 2.2 200 250 25 440
4 3 100L 1445 76.7 0.93 17.5 8.8 6 6 19.8 2.1 2.2 250 250 30 440
4 4 112M 1440 79 0.87 25 12.5 5.4 5.4 26.5 1.9 2.1 300 250 30 440
4 5.5 132S 1465 80.5 0.88 33 16.5 5.9 5.9 36 2.5 2.2 560 330 60 440
4 7.5 132M 1455 80.5 0.92 42 21 5.3 5.3 49 2.1 1.8 720 330 100 440

Source conditions: Tolerances according to IEC 34-1 and AS 1359.60. Efficiency — 15(1−η)% when P2 ≤50kW. Power factor cosφ — (1−cosφ)/6, minimum 0.02, maximum 0.07. Torque TN = (9550 × kW)/RPM Nm. Data subject to change without notice.

Catalogue context

Property Value Unit
Definitions and conversions 1kW = 1.34HP; 1HP = 0.746kW; 1Nm = 0.102kgmf. Ist/IN = Starting Current/Nominal F.L. Current; Tst/TN = Starting Torque/Nominal F.L. Torque; Tb/TN = Break down Torque/Nominal F.L. Torque.

Foot mounting IM1001

Catalogue page 8

IM1001 overall and mounting dimensions

Conditions: Dimensions in mm unless an explicit inch, rating, part or mass unit is printed. Values in explicitly merged cells are repeated only within their source row span. Empty output cells remain blank, not an inferred additional variant. Geometry remains in the original. Design, data and dimensions subject to modification without notice.

Series Frame Output 2P (kW) Output 4P (kW) Figure (figure reference) A (mm) AA (mm) AB (mm) AC (mm) AD (mm) AE (mm) B (mm) BA (mm) BB (mm) C (mm) H (mm) HA (mm) HC (mm) HD (mm) HE (mm) K (mm) KK (mm)
BECY 90S 1.5 1.1 2 140 35.5 170 200 170 128 100 130 56 90 10 190 17 10 22
BECY 90L 2.2 1.5 2 140 35.5 170 200 170 128 125 150 56 90 10 190 17 10 22
BECY 100L 3.0 2.2 3 160 45 195 219 180 138 140 175 63 100 12.5 243 27 12 22
BECY 100L 3.0 3 160 45 195 219 180 138 140 175 63 100 12.5 243 27 12 22
BECY 112M 4.0 4.0 3 190 45 224 238 236 147 140 175 70 112 14 265 39 12 22
BECY 132S 5.5 5.5 4 216 45 250 273 294 192 140 175 89 132 16 310 54 12 22
BECY 132S 7.5 4 216 45 250 273 294 192 140 175 89 132 16 310 54 12 22
BECY 132M 7.5 4 216 45 250 273 294 192 170 212 89 132 16 310 54 12 22

IM1001 shaft bearing and approximate mass

Series Frame Output 2P (kW) Output 4P (kW) Figure (figure reference) L (mm) LE (mm) LL (mm) Z (mm) D (mm) E (mm) ED (mm) F (mm) G (mm) GA (mm) Bearing D-END Bearing ND-END Approx. mass 2P (kg) Approx. mass 4P (kg)
BECY 90S 1.5 1.1 2 367 161 24 50 32 8 20 27 6205 ZZ 6205 ZZ 24.5 23
BECY 90L 2.2 1.5 2 392 161 24 50 32 8 20 27 6205 ZZ 6205 ZZ 31 26.8
BECY 100L 3.0 2.2 3 431 168 28 60 40 8 24 31 6206 ZZ 6305 ZZ 35 36
BECY 100L 3.0 3 431 168 28 60 40 8 24 31 6206 ZZ 6305 ZZ 39
BECY 112M 4.0 4.0 3 449 179 28 60 40 8 24 31 6306 ZZ 6306 ZZ 43.2 47.4
BECY 132S 5.5 5.5 4 508 199 38 80 56 10 33 41 6308 ZZ 6306 ZZ 77 75
BECY 132S 7.5 4 508 199 38 80 56 10 33 41 6308 ZZ 6306 ZZ 80
BECY 132M 7.5 4 546 199 38 80 56 10 33 41 6308 ZZ 6306 ZZ 81

Flange mounting IM3001 — BEDY catalogue designation

Catalogue page 9

IM3001 flange dimensions

Conditions: Dimensions in mm unless an explicit inch, rating, part or mass unit is printed. Values in explicitly merged cells are repeated only within their source row span. Empty output cells remain blank, not an inferred additional variant. Geometry remains in the original. Design, data and dimensions subject to modification without notice. Series are BETY/BEDY on this page; not silently relabelled BEGY/BECY.

Series Frame Output 2P (kW) Output 4P (kW) Figure (figure reference) AD (mm) AE (mm) HB (mm) HC (mm) KK (mm) L (mm) LA (mm) LB (mm) M (mm) N (mm) P (mm) S (mm) T (mm)
BEDY 90S 1.5 1.1 2 170 128 22 406 12 356 165 130 200 12 3.5
BEDY 90L 2.2 1.5 2 170 128 22 431 12 381 165 130 200 12 3.5
BEDY 100L 3.0 2.2 3 180 138 280 22 431 16 371 215 180 250 15 4
BEDY 100L 3.0 3 180 138 280 22 431 16 371 215 180 250 15 4
BEDY 112M 4.0 4.0 3 236 147 300 22 489 16 429 215 180 250 15 4
BEDY 132S 5.5 5.5 3 294 192 336 22 508 20 428 265 230 300 15 4
BEDY 132S 7.5 3 294 192 336 22 508 20 428 265 230 300 15 4
BEDY 132M 7.5 3 294 192 336 22 546 20 466 265 230 300 15 4

IM3001 shaft and bearing dimensions

Conditions: Dimensions in mm unless an explicit inch, rating, part or mass unit is printed. Values in explicitly merged cells are repeated only within their source row span. Empty output cells remain blank, not an inferred additional variant. Geometry remains in the original. Design, data and dimensions subject to modification without notice. Printed tolerance text: D = <28-j6, 38k6; F = h9; H = +0 −0.5; N = js6. Do not infer an unstated D=28 tolerance.

Series Frame Output 2P (kW) Output 4P (kW) Figure (figure reference) D (mm) E (mm) ED (mm) F (mm) G (mm) GA (mm) Bearing D-END Bearing ND-END
BEDY 90S 1.5 1.1 2 24 50 32 8 20 27 6205 ZZ 6205 ZZ
BEDY 90L 2.2 1.5 2 24 50 32 8 20 27 6205 ZZ 6205 ZZ
BEDY 100L 3.0 2.2 3 28 60 40 8 24 31 6206 ZZ 6305 ZZ
BEDY 100L 3.0 3 28 60 40 8 24 31 6206 ZZ 6305 ZZ
BEDY 112M 4.0 4.0 3 28 60 40 8 24 31 6306 ZZ 6306 ZZ
BEDY 132S 5.5 5.5 3 38 80 56 10 33 41 6308 ZZ 6306 ZZ
BEDY 132S 7.5 3 38 80 56 10 33 41 6308 ZZ 6306 ZZ
BEDY 132M 7.5 3 38 80 56 10 33 41 6308 ZZ 6306 ZZ

IM3001 tolerance

Property Value Unit
D <28-j6, 38k6
F h9
H +0 −0.5
N js6

Drawing callout

Property Value Unit
Flange figures 1–3 45°

Foot and flange mounting IM2001

Catalogue page 10

IM2001 foot and flange dimensions

Conditions: Dimensions in mm unless an explicit inch, rating, part or mass unit is printed. Values in explicitly merged cells are repeated only within their source row span. Empty output cells remain blank, not an inferred additional variant. Geometry remains in the original. Design, data and dimensions subject to modification without notice.

Series Frame Output 2P (kW) Output 4P (kW) Figure (figure reference) A (mm) AA (mm) AB (mm) AD (mm) AE (mm) B (mm) BA (mm) BB (mm) C (mm) H (mm) HA (mm) HC (mm) HD (mm) HE (mm) K (mm) KK (mm) L (mm) LA (mm) LB (mm)
BECY 90S 1.5 1.1 2 140 35.5 170 170 128 100 130 95 90 10 17 10 22 406 12 356
BECY 90L 2.2 1.5 2 140 35.5 170 170 128 125 150 95 90 10 17 10 22 431 12 381
BECY 100L 3.0 2.2 3 160 45 195 180 138 140 175 103 100 12.5 243 27 12 22 471 16 411
BECY 100L 3.0 3 160 45 195 180 138 140 175 103 100 12.5 243 27 12 22 471 16 411
BECY 112M 4.0 4.0 3 190 45 224 236 147 140 175 110 112 14 265 39 12 22 489 16 429
BECY 132S 5.5 5.5 4 216 45 250 294 192 140 175 139 132 16 310 54 12 22 558 20 478
BECY 132S 7.5 4 216 45 250 294 192 140 175 139 132 16 310 54 12 22 558 20 478
BECY 132M 7.5 4 216 45 250 294 192 178 212 139 132 16 310 54 12 22 596 20 516

IM2001 flange shaft and bearing dimensions

Series Frame Output 2P (kW) Output 4P (kW) Figure (figure reference) LL (mm) M (mm) N (mm) P (mm) S (mm) T (mm) Z (mm) D (mm) E (mm) ED (mm) F (mm) G (mm) GA (mm) Bearing D-END Bearing ND-END
BECY 90S 1.5 1.1 2 165 130 200 12 3.5 24 50 32 8 20 27 6205 ZZ 6205 ZZ
BECY 90L 2.2 1.5 2 165 130 200 12 3.5 24 50 32 8 20 27 6205 ZZ 6205 ZZ
BECY 100L 3.0 2.2 3 215 180 250 15 4 28 60 40 8 24 31 6206 ZZ 6305 ZZ
BECY 100L 3.0 3 215 180 250 15 4 28 60 40 8 24 31 6206 ZZ 6305 ZZ
BECY 112M 4.0 4.0 3 215 180 250 15 4 28 60 40 8 24 31 6306 ZZ 6306 ZZ
BECY 132S 5.5 5.5 4 265 230 300 15 4 38 80 56 10 33 41 6308 ZZ 6306 ZZ
BECY 132S 7.5 4 265 230 300 15 4 38 80 56 10 33 41 6308 ZZ 6306 ZZ
BECY 132M 7.5 4 265 230 300 15 4 38 80 56 10 33 41 6308 ZZ 6306 ZZ

Drawing callout

Property Value Unit
Figure 4 2 × M12 printed callout

BECY spare parts

Catalogue page 11

Spare parts list

Conditions: Dimensions in mm unless an explicit inch, rating, part or mass unit is printed. Values in explicitly merged cells are repeated only within their source row span. Empty output cells remain blank, not an inferred additional variant. Geometry remains in the original. Design, data and dimensions subject to modification without notice. Original kW–P column is split into output and pole count only. Capacitor ranges and x2/x4 multiplicity remain verbatim; no summed/replacement capacitor is inferred. Dashes are printed source dashes, not zeros.

Type Output (kW) Poles (poles) Centrifugal switch (part code) Capacitor START Capacitor RUN Thermal overload (part code) Bearing D-END Bearing ND-END
BECYBS 1.1 4 TS2RB4524 125uf 250V AC 15uf 440V AC MEJ 20RB 6205 ZZ 6205 ZZ
BECYBS 1.5 2 TS2RB2524 150uf 250V AC 15uf 440V AC MEJ 22AB 6205 ZZ 6205 ZZ
BECYBS 1.5 4 TS2RB4524 150uf 250V AC 15uf 440V AC MEJ 22AB 6205 ZZ 6205 ZZ
BECYBS 2.2 2 TS2RB2524 150uf 250V AC 20uf 440V AC — 6205 ZZ 6205 ZZ
BECYBS 2.2 4 TS2RB4524 200uf 250V AC 25uf 440V AC — 6206 ZZ 6305 ZZ
BECYBS 3 2 TS2RB2524 250uf 250V AC 15uf 440V ACx2 — 6206 ZZ 6305 ZZ
BECYBS 3 4 TS2RB4524 250uf 250V AC 15uf 440V ACx2 — 6206 ZZ 6305 ZZ
BECYBS 4 2 TS2RB2524 150uf 250V ACx2 15uf 440V ACx2 — 6306 ZZ 6306 ZZ
BECYBS 4 4 TS2RB4524 150uf 250V ACx2 15uf 440V ACx2 — 6206 ZZ 6306 ZZ
BECYBS 5.5 4 TS3RB4524 145-174uf 330V ACx4 15uf 440V ACx4 — 6308 ZZ 6306 ZZ
BECYBS 7.5 4 TS3RB4524 189-226uf 330V ACx4 25uf 440V ACx4 — 6308 ZZ 6306 ZZ
BECYBS 5.5 2 TS3RB2524 560uf 330V AC 60uf 440V AC — 6308 ZZ 6306 ZZ
BECYBS 7.5 2 TS3RB2524 720uf 330V AC 100uf 110V AC — 6308 ZZ 6306 ZZ

Catalogue page 12 — Historical contact back cover; current contact linked.

Individual datasheets and drawings

Each source retains its own ratings, dimensions, units, missing-value statements and qualifications. Blank or dash entries are not zero. Original drawings remain available for geometry, wiring and graphical information not captured in the tables. Dates and historical standards remain attached to the source edition.

2.2BE2 , 1.5BE4.pdf

Associated selection rows: 413, 414

PDFdrawings-495.zip > 90L FRAME/2.2BE2 , 1.5BE4.pdf.

Source page 1

Conditions for this section:

  • C1: Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

  • C2: Applies to the view and mounting printed on this source only. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

Specification Value Unit / basis Conditions
Identity / drawing_title OUTLINE DIMENSIONS — 1-PHASE INDUCTION MOTOR as printed —
Identity / frame D90L as printed —
Identity / drawing_number 2.2BE2 / 1.5BE4 as printed —
Identity / construction Totally Enclosed Fan Cooled Capacitor-Start & Run Type; Squirrel-Cage Rotor as printed —
Identity / date_as_printed 01.10.09 as printed —
Drawing / Overall axial length 392 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft extension 50 drawing units; not explicitly stated on this sheet C1
Drawing / Key length callout 32 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to terminal enclosure outer edge 170 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to cable-entry axis 128 drawing units; not explicitly stated on this sheet C1
Drawing / Cable-entry diameter Ø22 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft diameter and fit Ø24 j6 drawing units; not explicitly stated on this sheet C1
Drawing / Key width 8 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-and-key top height 27 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft keyseat lower-height callout 20 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-end thread and depth M8 TAP DEEP 12 drawing units; not explicitly stated on this sheet C1
Drawing / Height from foot mounting plane to topmost drawn projection 190 drawing units; not explicitly stated on this sheet C2
Drawing / Shaft height and tolerance 90 +0/-0.5 drawing units; not explicitly stated on this sheet C1
Drawing / Transverse mounting-hole centres 140 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall width 170 drawing units; not explicitly stated on this sheet C1
Drawing / Axial mounting-hole centres 125 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall axial length 150 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft shoulder to nearer foot-hole centre 56 drawing units; not explicitly stated on this sheet C1
Drawing / Rear foot-hole centre to fan end 161 drawing units; not explicitly stated on this sheet C1
Drawing / Foot slot-group width callout 35.5 drawing units; not explicitly stated on this sheet C1
Drawing / Foot thickness callout 10 drawing units; not explicitly stated on this sheet C1
Drawing / Lower terminal enclosure height above mounting plane 17 drawing units; not explicitly stated on this sheet C1
Drawing / Foot mounting holes 4-Ø10 Holes drawing units; not explicitly stated on this sheet C1
Drawing / Front-view body width callout 200 drawing units; not explicitly stated on this sheet C1
Drawing note / 1 FOOT MOUNTED IM1001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 FOR BELT OR DIRECT DRIVE. as printed —
Drawing note / 4 Dimensional units are not explicitly stated on this sheet; values and tolerances are transcribed as printed. as printed —
Drawing note / 5 SYNCH RPM is synchronous speed, not a measured full-load speed. Slash-separated ratings are retained as alternatives, not numeric ranges. as printed —

Electrical ratings as printed — P048, 2.2BE2 , 1.5BE4.pdf, page 1

Conditions for this section:

  • C1: Each row belongs only to this exact drawing and mounting; slash-separated alternatives are retained as printed. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 2.2 kW 3 HP 3000 rpm (synchronous) C1
2 4 poles 1.5 kW 2 HP 1500 rpm (synchronous) C1

2.2BF2 , 1.5BF4.pdf

Associated selection rows: 413, 414

PDFdrawings-495.zip > 90L FRAME/2.2BF2 , 1.5BF4.pdf.

Source page 1

Conditions for this section:

  • C1: Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / drawing_title OUTLINE DIMENSIONS — 1-PHASE INDUCTION MOTOR as printed —
Identity / frame D90L as printed —
Identity / drawing_number 2.2BF2 / 1.5BF4 as printed —
Identity / construction Totally Enclosed Fan Cooled Capacitor-Start & Run Type; Squirrel-Cage Rotor as printed —
Identity / date_as_printed 01.10.09 as printed —
Drawing / Overall axial length 431 drawing units; not explicitly stated on this sheet C1
Drawing / Flange face to fan end 381 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft extension 50 drawing units; not explicitly stated on this sheet C1
Drawing / Key length callout 32 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to terminal enclosure outer edge 170 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to cable-entry axis 128 drawing units; not explicitly stated on this sheet C1
Drawing / Cable-entry diameter Ø22 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft diameter and fit Ø24 j6 drawing units; not explicitly stated on this sheet C1
Drawing / Key width 8 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-and-key top height 27 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft keyseat lower-height callout 20 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-end thread and depth M8 TAP DEEP 12 drawing units; not explicitly stated on this sheet C1
Drawing / Flange outer diameter Ø200 drawing units; not explicitly stated on this sheet C1
Drawing / Flange pilot diameter and fit Ø130 h7 drawing units; not explicitly stated on this sheet C1
Drawing / Flange bolt pitch-circle diameter Ø165 drawing units; not explicitly stated on this sheet C1
Drawing / Flange thickness 12 drawing units; not explicitly stated on this sheet C1
Drawing / Flange register projection 3.5 drawing units; not explicitly stated on this sheet C1
Drawing / Flange bolt holes 4-Ø12 Holes as printed C1
Drawing / Flange hole angular offset 45 degrees C1
Drawing / Shaft height and tolerance 90 +0/-0.5 drawing units; not explicitly stated on this sheet C1
Drawing / Transverse mounting-hole centres 140 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall width 170 drawing units; not explicitly stated on this sheet C1
Drawing / Axial mounting-hole centres 125 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall axial length 150 drawing units; not explicitly stated on this sheet C1
Drawing / Flange face to nearer foot-hole centre 95 drawing units; not explicitly stated on this sheet C1
Drawing / Foot slot-group width callout 35.5 drawing units; not explicitly stated on this sheet C1
Drawing / Foot thickness callout 10 drawing units; not explicitly stated on this sheet C1
Drawing / Lower terminal enclosure height above mounting plane 17 drawing units; not explicitly stated on this sheet C1
Drawing / Foot mounting holes 4-Ø10 Holes drawing units; not explicitly stated on this sheet C1
Drawing note / 1 FOOT & FLANGE MOUNTED IM2001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 FOR BELT OR DIRECT DRIVE. as printed —
Drawing note / 4 Dimensional units are not explicitly stated on this sheet; values and tolerances are transcribed as printed. as printed —
Drawing note / 5 SYNCH RPM is synchronous speed, not a measured full-load speed. Slash-separated ratings are retained as alternatives, not numeric ranges. as printed —

Electrical ratings as printed — P048, 2.2BF2 , 1.5BF4.pdf, page 1

Conditions for this section:

  • C1: Each row belongs only to this exact drawing and mounting; slash-separated alternatives are retained as printed. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 2.2 kW 3 HP 3000 rpm (synchronous) C1
2 4 poles 1.5 kW 2 HP 1500 rpm (synchronous) C1

2.2BV2 , 1.5VB4.pdf

Associated selection rows: 413, 414

PDFdrawings-495.zip > 90L FRAME/2.2BV2 , 1.5VB4.pdf.

Source differences and limitations

  • Filename lists 1.5VB4; title block lists 1.5BV4. Printed title identity retained; original filename unchanged.

Source page 1

Conditions for this section:

  • C1: Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / drawing_title OUTLINE DIMENSIONS — 1-PHASE INDUCTION MOTOR as printed —
Identity / frame D90L as printed —
Identity / drawing_number 2.2BV2 / 1.5BV4 as printed —
Identity / construction Totally Enclosed Fan Cooled Capacitor-Start & Run Type; Squirrel-Cage Rotor as printed —
Identity / date_as_printed 01.10.09 as printed —
Drawing / Overall axial length 431 drawing units; not explicitly stated on this sheet C1
Drawing / Flange face to fan end 381 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft extension 50 drawing units; not explicitly stated on this sheet C1
Drawing / Key length callout 32 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to terminal enclosure outer edge 170 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to cable-entry axis 128 drawing units; not explicitly stated on this sheet C1
Drawing / Cable-entry diameter Ø22 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft diameter and fit Ø24 j6 drawing units; not explicitly stated on this sheet C1
Drawing / Key width 8 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-and-key top height 27 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft keyseat lower-height callout 20 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-end thread and depth M8 TAP DEEP 12 drawing units; not explicitly stated on this sheet C1
Drawing / Flange outer diameter Ø200 drawing units; not explicitly stated on this sheet C1
Drawing / Flange pilot diameter and fit Ø130 h7 drawing units; not explicitly stated on this sheet C1
Drawing / Flange bolt pitch-circle diameter Ø165 drawing units; not explicitly stated on this sheet C1
Drawing / Flange thickness 12 drawing units; not explicitly stated on this sheet C1
Drawing / Flange register projection 3.5 drawing units; not explicitly stated on this sheet C1
Drawing / Flange bolt holes 4-Ø12 Holes as printed C1
Drawing / Flange hole angular offset 45 degrees C1
Drawing note / 1 FLANGE MOUNTED IM3001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 FOR BELT OR DIRECT DRIVE. as printed —
Drawing note / 4 Dimensional units are not explicitly stated on this sheet; values and tolerances are transcribed as printed. as printed —
Drawing note / 5 SYNCH RPM is synchronous speed, not a measured full-load speed. Slash-separated ratings are retained as alternatives, not numeric ranges. as printed —

Electrical ratings as printed — P048, 2.2BV2 , 1.5VB4.pdf, page 1

Conditions for this section:

  • C1: Each row belongs only to this exact drawing and mounting; slash-separated alternatives are retained as printed. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 2.2 kW 3 HP 3000 rpm (synchronous) C1
2 4 poles 1.5 kW 2 HP 1500 rpm (synchronous) C1

Datasheet-495.pdf

Associated selection rows: 413

Datasheet-495.pdf.

Source differences and limitations

  • Website/source difference — VOLTAGE: website 240; PDF page 1 240/480. Website row IDs: 413. Neither is automatically substituted for the other.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BECY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 1.5 —
VOLTAGE 240/480 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 4 —
FRAME D90L —
SPEED / SYNCHRONOUS 1500 (rpm) —
SPEED / FULL LOAD 1450 (rpm) —
CURRENT / FULL LOAD 10.4 / 5.2 (Amps) —
CURRENT / LOCKED ROTOR 580 % —
TORQUE / FULL LOAD TORQUE 9.9 (Nm) —
TORQUE / STARTING TORQUE 240 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 220 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 72.8 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 82 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING 44 —
WEIGHT OF MOTOR 26.8 kgs —
BEARINGS / DRIVE END 6205 ZZ —
BEARINGS / NON DRIVE END 6205 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

Datasheet-489.pdf

Associated selection rows: 414

Datasheet-489.pdf.

Source differences and limitations

  • Website/source difference — VOLTAGE: website 240; PDF page 1 240/480. Website row IDs: 414. Neither is automatically substituted for the other.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BECY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 2.2 —
VOLTAGE 240/480 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 2 —
FRAME D90L —
SPEED / SYNCHRONOUS 3000 (rpm) —
SPEED / FULL LOAD 2895 (rpm) —
CURRENT / FULL LOAD 13.1 / 6.55 (Amps) —
CURRENT / LOCKED ROTOR 670 % —
TORQUE / FULL LOAD TORQUE 7.3 (Nm) —
TORQUE / STARTING TORQUE 210 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 250 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 77.9 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 92 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING 44 —
WEIGHT OF MOTOR 31 kgs —
BEARINGS / DRIVE END 6205 ZZ —
BEARINGS / NON DRIVE END 6205 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

1.5BE2 , 1.1BE4.pdf

Associated selection rows: 415, 416

PDFdrawings-494.zip > 90S FRAME/1.5BE2 , 1.1BE4.pdf.

Source page 1

Conditions for this section:

  • C1: Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

  • C2: Applies to the view and mounting printed on this source only. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

Specification Value Unit / basis Conditions
Identity / drawing_title OUTLINE DIMENSIONS — 1-PHASE INDUCTION MOTOR as printed —
Identity / frame D90S as printed —
Identity / drawing_number 1.5BE2 / 1.1BE4 as printed —
Identity / construction Totally Enclosed Fan Cooled Capacitor-Start & Run Type; Squirrel-Cage Rotor as printed —
Identity / date_as_printed 01.10.09 as printed —
Drawing / Overall axial length 367 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft extension 50 drawing units; not explicitly stated on this sheet C1
Drawing / Key length callout 32 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to terminal enclosure outer edge 170 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to cable-entry axis 128 drawing units; not explicitly stated on this sheet C1
Drawing / Cable-entry diameter Ø22 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft diameter and fit Ø24 j6 drawing units; not explicitly stated on this sheet C1
Drawing / Key width 8 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-and-key top height 27 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft keyseat lower-height callout 20 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-end thread and depth M8 TAP DEEP 12 drawing units; not explicitly stated on this sheet C1
Drawing / Height from foot mounting plane to topmost drawn projection 190 drawing units; not explicitly stated on this sheet C2
Drawing / Shaft height and tolerance 90 +0/-0.5 drawing units; not explicitly stated on this sheet C1
Drawing / Transverse mounting-hole centres 140 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall width 170 drawing units; not explicitly stated on this sheet C1
Drawing / Axial mounting-hole centres 100 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall axial length 130 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft shoulder to nearer foot-hole centre 56 drawing units; not explicitly stated on this sheet C1
Drawing / Rear foot-hole centre to fan end 161 drawing units; not explicitly stated on this sheet C1
Drawing / Foot slot-group width callout 35.5 drawing units; not explicitly stated on this sheet C1
Drawing / Foot thickness callout 10 drawing units; not explicitly stated on this sheet C1
Drawing / Lower terminal enclosure height above mounting plane 17 drawing units; not explicitly stated on this sheet C1
Drawing / Foot mounting holes 4-Ø10 Holes drawing units; not explicitly stated on this sheet C1
Drawing / Front-view body width callout 200 drawing units; not explicitly stated on this sheet C1
Drawing note / 1 FOOT MOUNTED IM1001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 FOR BELT OR DIRECT DRIVE. as printed —
Drawing note / 4 Dimensional units are not explicitly stated on this sheet; values and tolerances are transcribed as printed. as printed —
Drawing note / 5 SYNCH RPM is synchronous speed, not a measured full-load speed. Slash-separated ratings are retained as alternatives, not numeric ranges. as printed —

Electrical ratings as printed — P048, 1.5BE2 , 1.1BE4.pdf, page 1

Conditions for this section:

  • C1: Each row belongs only to this exact drawing and mounting; slash-separated alternatives are retained as printed. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 1.5 kW 2 HP 3000 rpm (synchronous) C1
2 4 poles 1.1 kW 1.5 HP 1500 rpm (synchronous) C1

1.5BF2 , 1.1BF4.pdf

Associated selection rows: 415, 416

PDFdrawings-494.zip > 90S FRAME/1.5BF2 , 1.1BF4.pdf.

Source page 1

Conditions for this section:

  • C1: Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / drawing_title OUTLINE DIMENSIONS — 1-PHASE INDUCTION MOTOR as printed —
Identity / frame D90S as printed —
Identity / drawing_number 1.5BF2 / 1.1BF4 as printed —
Identity / construction Totally Enclosed Fan Cooled Capacitor-Start & Run Type; Squirrel-Cage Rotor as printed —
Identity / date_as_printed 01.10.09 as printed —
Drawing / Overall axial length 406 drawing units; not explicitly stated on this sheet C1
Drawing / Flange face to fan end 356 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft extension 50 drawing units; not explicitly stated on this sheet C1
Drawing / Key length callout 32 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to terminal enclosure outer edge 170 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to cable-entry axis 128 drawing units; not explicitly stated on this sheet C1
Drawing / Cable-entry diameter Ø22 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft diameter and fit Ø24 j6 drawing units; not explicitly stated on this sheet C1
Drawing / Key width 8 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-and-key top height 27 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft keyseat lower-height callout 20 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-end thread and depth M8 TAP DEEP 12 drawing units; not explicitly stated on this sheet C1
Drawing / Flange outer diameter Ø200 drawing units; not explicitly stated on this sheet C1
Drawing / Flange pilot diameter and fit Ø130 h7 drawing units; not explicitly stated on this sheet C1
Drawing / Flange bolt pitch-circle diameter Ø165 drawing units; not explicitly stated on this sheet C1
Drawing / Flange thickness 12 drawing units; not explicitly stated on this sheet C1
Drawing / Flange register projection 3.5 drawing units; not explicitly stated on this sheet C1
Drawing / Flange bolt holes 4-Ø12 Holes as printed C1
Drawing / Flange hole angular offset 45 degrees C1
Drawing / Shaft height and tolerance 90 +0/-0.5 drawing units; not explicitly stated on this sheet C1
Drawing / Transverse mounting-hole centres 140 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall width 170 drawing units; not explicitly stated on this sheet C1
Drawing / Axial mounting-hole centres 100 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall axial length 130 drawing units; not explicitly stated on this sheet C1
Drawing / Flange face to nearer foot-hole centre 95 drawing units; not explicitly stated on this sheet C1
Drawing / Foot slot-group width callout 35.5 drawing units; not explicitly stated on this sheet C1
Drawing / Foot thickness callout 10 drawing units; not explicitly stated on this sheet C1
Drawing / Lower terminal enclosure height above mounting plane 17 drawing units; not explicitly stated on this sheet C1
Drawing / Foot mounting holes 4-Ø10 Holes drawing units; not explicitly stated on this sheet C1
Drawing note / 1 FOOT & FLANGE MOUNTED IM2001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 FOR BELT OR DIRECT DRIVE. as printed —
Drawing note / 4 Dimensional units are not explicitly stated on this sheet; values and tolerances are transcribed as printed. as printed —
Drawing note / 5 SYNCH RPM is synchronous speed, not a measured full-load speed. Slash-separated ratings are retained as alternatives, not numeric ranges. as printed —

Electrical ratings as printed — P048, 1.5BF2 , 1.1BF4.pdf, page 1

Conditions for this section:

  • C1: Each row belongs only to this exact drawing and mounting; slash-separated alternatives are retained as printed. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 1.5 kW 2 HP 3000 rpm (synchronous) C1
2 4 poles 1.1 kW 1.5 HP 1500 rpm (synchronous) C1

1.5BV2 , 1.1BV4.pdf

Associated selection rows: 415, 416

PDFdrawings-494.zip > 90S FRAME/1.5BV2 , 1.1BV4.pdf.

Source page 1

Conditions for this section:

  • C1: Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Specification Value Unit / basis Conditions
Identity / drawing_title OUTLINE DIMENSIONS — 1-PHASE INDUCTION MOTOR as printed —
Identity / frame D90S as printed —
Identity / drawing_number 1.5BV2 / 1.1BV4 as printed —
Identity / construction Totally Enclosed Fan Cooled Capacitor-Start & Run Type; Squirrel-Cage Rotor as printed —
Identity / date_as_printed 01.10.09 as printed —
Drawing / Overall axial length 406 drawing units; not explicitly stated on this sheet C1
Drawing / Flange face to fan end 356 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft extension 50 drawing units; not explicitly stated on this sheet C1
Drawing / Key length callout 32 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to terminal enclosure outer edge 170 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to cable-entry axis 128 drawing units; not explicitly stated on this sheet C1
Drawing / Cable-entry diameter Ø22 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft diameter and fit Ø24 j6 drawing units; not explicitly stated on this sheet C1
Drawing / Key width 8 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-and-key top height 27 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft keyseat lower-height callout 20 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-end thread and depth M8 TAP DEEP 12 drawing units; not explicitly stated on this sheet C1
Drawing / Flange outer diameter Ø200 drawing units; not explicitly stated on this sheet C1
Drawing / Flange pilot diameter and fit Ø130 h7 drawing units; not explicitly stated on this sheet C1
Drawing / Flange bolt pitch-circle diameter Ø165 drawing units; not explicitly stated on this sheet C1
Drawing / Flange thickness 12 drawing units; not explicitly stated on this sheet C1
Drawing / Flange register projection 3.5 drawing units; not explicitly stated on this sheet C1
Drawing / Flange bolt holes 4-Ø12 Holes as printed C1
Drawing / Flange hole angular offset 45 degrees C1
Drawing note / 1 FLANGE MOUNTED IM3001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 FOR BELT OR DIRECT DRIVE. as printed —
Drawing note / 4 Dimensional units are not explicitly stated on this sheet; values and tolerances are transcribed as printed. as printed —
Drawing note / 5 SYNCH RPM is synchronous speed, not a measured full-load speed. Slash-separated ratings are retained as alternatives, not numeric ranges. as printed —

Electrical ratings as printed — P048, 1.5BV2 , 1.1BV4.pdf, page 1

Conditions for this section:

  • C1: Each row belongs only to this exact drawing and mounting; slash-separated alternatives are retained as printed. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 1.5 kW 2 HP 3000 rpm (synchronous) C1
2 4 poles 1.1 kW 1.5 HP 1500 rpm (synchronous) C1

Datasheet-494.pdf

Associated selection rows: 415

Datasheet-494.pdf.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BECY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 1.1 —
VOLTAGE 240 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 4 —
FRAME D90S —
SPEED / SYNCHRONOUS 1500 (rpm) —
SPEED / FULL LOAD 1445 (rpm) —
CURRENT / FULL LOAD 8.8 (Amps) —
CURRENT / LOCKED ROTOR 510 % —
TORQUE / FULL LOAD TORQUE 7.3 (Nm) —
TORQUE / STARTING TORQUE 220 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 220 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 69.6 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 76 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING 44 —
WEIGHT OF MOTOR 23 kgs —
BEARINGS / DRIVE END 6205 ZZ —
BEARINGS / NON DRIVE END 6205 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

Datasheet-488.pdf

Associated selection rows: 416

Datasheet-488.pdf.

Source differences and limitations

  • Website/source difference — VOLTAGE: website 240; PDF page 1 240/480. Website row IDs: 416. Neither is automatically substituted for the other.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BECY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 1.5 —
VOLTAGE 240/480 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 2 —
FRAME D90S —
SPEED / SYNCHRONOUS 3000 (rpm) —
SPEED / FULL LOAD 2910 (rpm) —
CURRENT / FULL LOAD 9 / 4.5 (Amps) —
CURRENT / LOCKED ROTOR 700 % —
TORQUE / FULL LOAD TORQUE 4.9 (Nm) —
TORQUE / STARTING TORQUE 230 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 260 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 77.5 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 89 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING 44 —
WEIGHT OF MOTOR 24.5 kgs —
BEARINGS / DRIVE END 6205 ZZ —
BEARINGS / NON DRIVE END 6205 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

3BE2 , 2.2BE4 , 3BE4.pdf

Associated selection rows: 417, 418, 419

PDFdrawings-497.zip > 100L FRAME/3BE2 , 2.2BE4 , 3BE4.pdf.

Source page 1

Conditions for this section:

  • C1: Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

  • C2: Applies to the view and mounting printed on this source only. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

Specification Value Unit / basis Conditions
Identity / drawing_title OUTLINE DIMENSIONS — 1-PHASE INDUCTION MOTOR as printed —
Identity / frame D100L as printed —
Identity / drawing_number 2.2BE4 / 3BE2 / 3BE4 as printed —
Identity / construction Totally Enclosed Fan Cooled Capacitor-Start & Run Type; Squirrel-Cage Rotor as printed —
Identity / date_as_printed 01.10.09 as printed —
Drawing / Overall axial length 431 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft extension 60 drawing units; not explicitly stated on this sheet C1
Drawing / Key length callout 40 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to terminal enclosure outer edge 180 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to cable-entry axis 138 drawing units; not explicitly stated on this sheet C1
Drawing / Cable-entry diameter Ø22 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft diameter and fit Ø28 j6 drawing units; not explicitly stated on this sheet C1
Drawing / Key width 8 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-and-key top height 31 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft keyseat lower-height callout 24 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-end thread and depth M10 TAP DEEP 15 drawing units; not explicitly stated on this sheet C1
Drawing / Height from foot mounting plane to topmost drawn projection 243 drawing units; not explicitly stated on this sheet C2
Drawing / Shaft height and tolerance 100 +0/-0.5 drawing units; not explicitly stated on this sheet C1
Drawing / Transverse mounting-hole centres 160 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall width 195 drawing units; not explicitly stated on this sheet C1
Drawing / Axial mounting-hole centres 140 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall axial length 175 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft shoulder to nearer foot-hole centre 63 drawing units; not explicitly stated on this sheet C1
Drawing / Rear foot-hole centre to fan end 168 drawing units; not explicitly stated on this sheet C1
Drawing / Foot slot-group width callout 45 drawing units; not explicitly stated on this sheet C1
Drawing / Foot thickness callout 12.5 drawing units; not explicitly stated on this sheet C1
Drawing / Lower terminal enclosure height above mounting plane 27 drawing units; not explicitly stated on this sheet C1
Drawing / Foot mounting holes 4-Ø12 Holes drawing units; not explicitly stated on this sheet C1
Drawing / Front-view body width callout 219 drawing units; not explicitly stated on this sheet C1
Drawing note / 1 FOOT MOUNTED IM1001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 FOR BELT OR DIRECT DRIVE. as printed —
Drawing note / 4 Dimensional units are not explicitly stated on this sheet; values and tolerances are transcribed as printed. as printed —
Drawing note / 5 SYNCH RPM is synchronous speed, not a measured full-load speed. Slash-separated ratings are retained as alternatives, not numeric ranges. as printed —

Electrical ratings as printed — P048, 3BE2 , 2.2BE4 , 3BE4.pdf, page 1

Conditions for this section:

  • C1: Each row belongs only to this exact drawing and mounting; slash-separated alternatives are retained as printed. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 3 kW 4 HP 3000 rpm (synchronous) C1
2 4 poles 2.2/3 kW 3/4 HP 1500 rpm (synchronous) C1

3BF2 , 2.2BF4 , 3BF4.pdf

Associated selection rows: 417, 418, 419

PDFdrawings-497.zip > 100L FRAME/3BF2 , 2.2BF4 , 3BF4.pdf.

Source page 1

Conditions for this section:

  • C1: Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

  • C2: Applies to the view and mounting printed on this source only. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

Specification Value Unit / basis Conditions
Identity / drawing_title OUTLINE DIMENSIONS — 1-PHASE INDUCTION MOTOR as printed —
Identity / frame D100L as printed —
Identity / drawing_number 2.2BF4 / 3BF2 / 3BF4 as printed —
Identity / construction Totally Enclosed Fan Cooled Capacitor-Start & Run Type; Squirrel-Cage Rotor as printed —
Identity / date_as_printed 01.10.09 as printed —
Drawing / Overall axial length 471 drawing units; not explicitly stated on this sheet C1
Drawing / Flange face to fan end 411 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft extension 60 drawing units; not explicitly stated on this sheet C1
Drawing / Key length callout 40 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to terminal enclosure outer edge 180 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to cable-entry axis 138 drawing units; not explicitly stated on this sheet C1
Drawing / Cable-entry diameter Ø22 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft diameter and fit Ø28 j6 drawing units; not explicitly stated on this sheet C1
Drawing / Key width 8 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-and-key top height 31 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft keyseat lower-height callout 24 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-end thread and depth M10 TAP DEEP 15 drawing units; not explicitly stated on this sheet C1
Drawing / Flange outer diameter Ø250 drawing units; not explicitly stated on this sheet C1
Drawing / Flange pilot diameter and fit Ø180 h7 drawing units; not explicitly stated on this sheet C1
Drawing / Flange bolt pitch-circle diameter Ø215 drawing units; not explicitly stated on this sheet C1
Drawing / Flange thickness 16 drawing units; not explicitly stated on this sheet C1
Drawing / Flange register projection 4 drawing units; not explicitly stated on this sheet C1
Drawing / Height from foot mounting plane to topmost drawn projection 243 drawing units; not explicitly stated on this sheet C2
Drawing / Flange bolt holes 4-Ø15 Holes as printed C1
Drawing / Flange hole angular offset 45 degrees C1
Drawing / Shaft height and tolerance 100 +0/-0.5 drawing units; not explicitly stated on this sheet C1
Drawing / Transverse mounting-hole centres 160 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall width 195 drawing units; not explicitly stated on this sheet C1
Drawing / Axial mounting-hole centres 140 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall axial length 175 drawing units; not explicitly stated on this sheet C1
Drawing / Flange face to nearer foot-hole centre 103 drawing units; not explicitly stated on this sheet C1
Drawing / Foot slot-group width callout 45 drawing units; not explicitly stated on this sheet C1
Drawing / Foot thickness callout 12.5 drawing units; not explicitly stated on this sheet C1
Drawing / Lower terminal enclosure height above mounting plane 27 drawing units; not explicitly stated on this sheet C1
Drawing / Foot mounting holes 4-Ø12 Holes drawing units; not explicitly stated on this sheet C1
Drawing note / 1 FOOT & FLANGE MOUNTED IM2001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 FOR BELT OR DIRECT DRIVE. as printed —
Drawing note / 4 Dimensional units are not explicitly stated on this sheet; values and tolerances are transcribed as printed. as printed —
Drawing note / 5 SYNCH RPM is synchronous speed, not a measured full-load speed. Slash-separated ratings are retained as alternatives, not numeric ranges. as printed —

Electrical ratings as printed — P048, 3BF2 , 2.2BF4 , 3BF4.pdf, page 1

Conditions for this section:

  • C1: Each row belongs only to this exact drawing and mounting; slash-separated alternatives are retained as printed. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 3 kW 4 HP 3000 rpm (synchronous) C1
2 4 poles 2.2/3 kW 3/4 HP 1500 rpm (synchronous) C1

3BV2 , 2.2BV4 , 3BV4.pdf

Associated selection rows: 417, 418, 419

PDFdrawings-497.zip > 100L FRAME/3BV2 , 2.2BV4 , 3BV4.pdf.

Source page 1

Conditions for this section:

  • C1: Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

  • C2: Applies to the view and mounting printed on this source only. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

Specification Value Unit / basis Conditions
Identity / drawing_title OUTLINE DIMENSIONS — 1-PHASE INDUCTION MOTOR as printed —
Identity / frame D100L as printed —
Identity / drawing_number 3BV2 / 2.2BV4 / 3BV4 as printed —
Identity / construction Totally Enclosed Fan Cooled Capacitor-Start & Run Type; Squirrel-Cage Rotor as printed —
Identity / date_as_printed 01.10.09 as printed —
Drawing / Overall axial length 431 drawing units; not explicitly stated on this sheet C1
Drawing / Flange face to fan end 371 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft extension 60 drawing units; not explicitly stated on this sheet C1
Drawing / Key length callout 40 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to terminal enclosure outer edge 180 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to cable-entry axis 138 drawing units; not explicitly stated on this sheet C1
Drawing / Cable-entry diameter Ø22 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft diameter and fit Ø28 j6 drawing units; not explicitly stated on this sheet C1
Drawing / Key width 8 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-and-key top height 31 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft keyseat lower-height callout 24 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-end thread and depth M10 TAP DEEP 15 drawing units; not explicitly stated on this sheet C1
Drawing / Flange outer diameter Ø250 drawing units; not explicitly stated on this sheet C1
Drawing / Flange pilot diameter and fit Ø180 h7 drawing units; not explicitly stated on this sheet C1
Drawing / Flange bolt pitch-circle diameter Ø215 drawing units; not explicitly stated on this sheet C1
Drawing / Flange thickness 16 drawing units; not explicitly stated on this sheet C1
Drawing / Flange register projection 4 drawing units; not explicitly stated on this sheet C1
Drawing / Side-view vertical envelope including projections 280 drawing units; not explicitly stated on this sheet C2
Drawing / Flange bolt holes 4-Ø15 Holes as printed C1
Drawing / Flange hole angular offset 45 degrees C1
Drawing note / 1 FLANGE MOUNTED IM3001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 FOR BELT OR DIRECT DRIVE. as printed —
Drawing note / 4 Dimensional units are not explicitly stated on this sheet; values and tolerances are transcribed as printed. as printed —
Drawing note / 5 SYNCH RPM is synchronous speed, not a measured full-load speed. Slash-separated ratings are retained as alternatives, not numeric ranges. as printed —

Electrical ratings as printed — P048, 3BV2 , 2.2BV4 , 3BV4.pdf, page 1

Conditions for this section:

  • C1: Each row belongs only to this exact drawing and mounting; slash-separated alternatives are retained as printed. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 3 kW 4 HP 3000 rpm (synchronous) C1
2 4 poles 2.2/3 kW 3/4 HP 1500 rpm (synchronous) C1

Datasheet-496.pdf

Associated selection rows: 417

Datasheet-496.pdf.

Source differences and limitations

  • Website/source difference — VOLTAGE: website 240; PDF page 1 240/480. Website row IDs: 417. Neither is automatically substituted for the other.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BECY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 2.2 —
VOLTAGE 240/480 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 4 —
FRAME D100L —
SPEED / SYNCHRONOUS 1500 (rpm) —
SPEED / FULL LOAD 1455 (rpm) —
CURRENT / FULL LOAD 13.3 / 6.7 (Amps) —
CURRENT / LOCKED ROTOR 570 % —
TORQUE / FULL LOAD TORQUE 14.4 (Nm) —
TORQUE / STARTING TORQUE 180 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 220 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 76.4 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 92 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING 44 —
WEIGHT OF MOTOR 36 kgs —
BEARINGS / DRIVE END 6206 ZZ —
BEARINGS / NON DRIVE END 6305 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

Datasheet-490.pdf

Associated selection rows: 418

Datasheet-490.pdf.

Source differences and limitations

  • Website/source difference — VOLTAGE: website 240; PDF page 1 240/480. Website row IDs: 418. Neither is automatically substituted for the other.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BECY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 3 —
VOLTAGE 240/480 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 2 —
FRAME D100L —
SPEED / SYNCHRONOUS 3000 (rpm) —
SPEED / FULL LOAD 2875 (rpm) —
CURRENT / FULL LOAD 18.0 / 9 (Amps) —
CURRENT / LOCKED ROTOR 590 % —
TORQUE / FULL LOAD TORQUE 10 (Nm) —
TORQUE / STARTING TORQUE 250 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 230 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 75.6 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 92 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING 44 —
WEIGHT OF MOTOR 35 kgs —
BEARINGS / DRIVE END 6206 ZZ —
BEARINGS / NON DRIVE END 6305 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

Datasheet-497.pdf

Associated selection rows: 419

Datasheet-497.pdf.

Source differences and limitations

  • Website/source difference — VOLTAGE: website 240; PDF page 1 240/480. Website row IDs: 419. Neither is automatically substituted for the other.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BECY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 3 —
VOLTAGE 240/480 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 4 —
FRAME D100L —
SPEED / SYNCHRONOUS 1500 (rpm) —
SPEED / FULL LOAD 1445 (rpm) —
CURRENT / FULL LOAD 17.5 / 8.8 (Amps) —
CURRENT / LOCKED ROTOR 600 % —
TORQUE / FULL LOAD TORQUE 19.8 (Nm) —
TORQUE / STARTING TORQUE 210 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 220 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 76.7 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 93 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING 44 —
WEIGHT OF MOTOR 39 kgs —
BEARINGS / DRIVE END 6206 ZZ —
BEARINGS / NON DRIVE END 6305 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

4BE2 , 4BE4.pdf

Associated selection rows: 420, 421

PDFdrawings-498.zip > 112M FRAME/4BE2 , 4BE4.pdf.

Source page 1

Conditions for this section:

  • C1: Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

  • C2: Applies to the view and mounting printed on this source only. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

Specification Value Unit / basis Conditions
Identity / drawing_title OUTLINE DIMENSIONS — 1-PHASE INDUCTION MOTOR as printed —
Identity / frame D112M as printed —
Identity / drawing_number 4BE2 / 4BE4 as printed —
Identity / construction Totally Enclosed Fan Cooled Capacitor-Start & Run Type; Squirrel-Cage Rotor as printed —
Identity / date_as_printed 01.10.09 as printed —
Drawing / Overall axial length 449 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft extension 60 drawing units; not explicitly stated on this sheet C1
Drawing / Key length callout 40 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to terminal enclosure outer edge 236 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to cable-entry axis 147 drawing units; not explicitly stated on this sheet C1
Drawing / Cable-entry diameter Ø22 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft diameter and fit Ø28 j6 drawing units; not explicitly stated on this sheet C1
Drawing / Key width 8 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-and-key top height 31 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft keyseat lower-height callout 24 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-end thread and depth M10 TAP DEEP 15 drawing units; not explicitly stated on this sheet C1
Drawing / Height from foot mounting plane to topmost drawn projection 265 drawing units; not explicitly stated on this sheet C2
Drawing / Shaft height and tolerance 112 +0/-0.5 drawing units; not explicitly stated on this sheet C1
Drawing / Transverse mounting-hole centres 190 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall width 224 drawing units; not explicitly stated on this sheet C1
Drawing / Axial mounting-hole centres 140 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall axial length 175 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft shoulder to nearer foot-hole centre 70 drawing units; not explicitly stated on this sheet C1
Drawing / Rear foot-hole centre to fan end 179 drawing units; not explicitly stated on this sheet C1
Drawing / Foot slot-group width callout 45 drawing units; not explicitly stated on this sheet C1
Drawing / Foot thickness callout 14 drawing units; not explicitly stated on this sheet C1
Drawing / Lower terminal enclosure height above mounting plane 39 drawing units; not explicitly stated on this sheet C1
Drawing / Foot mounting holes 4-Ø12 Holes drawing units; not explicitly stated on this sheet C1
Drawing / Front-view body width callout 238 drawing units; not explicitly stated on this sheet C1
Drawing note / 1 FOOT MOUNTED IM1001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 FOR BELT OR DIRECT DRIVE. as printed —
Drawing note / 4 Dimensional units are not explicitly stated on this sheet; values and tolerances are transcribed as printed. as printed —
Drawing note / 5 SYNCH RPM is synchronous speed, not a measured full-load speed. Slash-separated ratings are retained as alternatives, not numeric ranges. as printed —

Electrical ratings as printed — P048, 4BE2 , 4BE4.pdf, page 1

Conditions for this section:

  • C1: Each row belongs only to this exact drawing and mounting; slash-separated alternatives are retained as printed. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 4 kW 5.5 HP 3000 rpm (synchronous) C1
2 4 poles 4 kW 5.5 HP 1500 rpm (synchronous) C1

4BF2 , 4BF4.pdf

Associated selection rows: 420, 421

PDFdrawings-498.zip > 112M FRAME/4BF2 , 4BF4.pdf.

Source page 1

Conditions for this section:

  • C1: Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

  • C2: Applies to the view and mounting printed on this source only. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

Specification Value Unit / basis Conditions
Identity / drawing_title OUTLINE DIMENSIONS — 1-PHASE INDUCTION MOTOR as printed —
Identity / frame D112M as printed —
Identity / drawing_number 4BF2 / 4BF4 as printed —
Identity / construction Totally Enclosed Fan Cooled Capacitor-Start & Run Type; Squirrel-Cage Rotor as printed —
Identity / date_as_printed 01.10.09 as printed —
Drawing / Overall axial length 489 drawing units; not explicitly stated on this sheet C1
Drawing / Flange face to fan end 429 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft extension 60 drawing units; not explicitly stated on this sheet C1
Drawing / Key length callout 40 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to terminal enclosure outer edge 236 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to cable-entry axis 147 drawing units; not explicitly stated on this sheet C1
Drawing / Cable-entry diameter Ø22 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft diameter and fit Ø28 j6 drawing units; not explicitly stated on this sheet C1
Drawing / Key width 8 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-and-key top height 31 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft keyseat lower-height callout 24 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-end thread and depth M10 TAP DEEP 15 drawing units; not explicitly stated on this sheet C1
Drawing / Flange outer diameter Ø250 drawing units; not explicitly stated on this sheet C1
Drawing / Flange pilot diameter and fit Ø180 h7 drawing units; not explicitly stated on this sheet C1
Drawing / Flange bolt pitch-circle diameter Ø215 drawing units; not explicitly stated on this sheet C1
Drawing / Flange thickness 16 drawing units; not explicitly stated on this sheet C1
Drawing / Flange register projection 4 drawing units; not explicitly stated on this sheet C1
Drawing / Height from foot mounting plane to topmost drawn projection 265 drawing units; not explicitly stated on this sheet C2
Drawing / Flange bolt holes 4-Ø15 Holes as printed C1
Drawing / Flange hole angular offset 45 degrees C1
Drawing / Shaft height and tolerance 112 +0/-0.5 drawing units; not explicitly stated on this sheet C1
Drawing / Transverse mounting-hole centres 190 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall width 224 drawing units; not explicitly stated on this sheet C1
Drawing / Axial mounting-hole centres 140 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall axial length 175 drawing units; not explicitly stated on this sheet C1
Drawing / Flange face to nearer foot-hole centre 110 drawing units; not explicitly stated on this sheet C1
Drawing / Foot slot-group width callout 45 drawing units; not explicitly stated on this sheet C1
Drawing / Foot thickness callout 14 drawing units; not explicitly stated on this sheet C1
Drawing / Lower terminal enclosure height above mounting plane 39 drawing units; not explicitly stated on this sheet C1
Drawing / Foot mounting holes 4-Ø12 Holes drawing units; not explicitly stated on this sheet C1
Drawing note / 1 FOOT & FLANGE MOUNTED IM2001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 FOR BELT OR DIRECT DRIVE. as printed —
Drawing note / 4 Dimensional units are not explicitly stated on this sheet; values and tolerances are transcribed as printed. as printed —
Drawing note / 5 SYNCH RPM is synchronous speed, not a measured full-load speed. Slash-separated ratings are retained as alternatives, not numeric ranges. as printed —

Electrical ratings as printed — P048, 4BF2 , 4BF4.pdf, page 1

Conditions for this section:

  • C1: Each row belongs only to this exact drawing and mounting; slash-separated alternatives are retained as printed. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 4 kW 5.5 HP 3000 rpm (synchronous) C1
2 4 poles 4 kW 5.5 HP 1500 rpm (synchronous) C1

4BV2 , 4BV4.pdf

Associated selection rows: 420, 421

PDFdrawings-498.zip > 112M FRAME/4BV2 , 4BV4.pdf.

Source page 1

Conditions for this section:

  • C1: Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

  • C2: Applies to the view and mounting printed on this source only. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

Specification Value Unit / basis Conditions
Identity / drawing_title OUTLINE DIMENSIONS — 1-PHASE INDUCTION MOTOR as printed —
Identity / frame D112M as printed —
Identity / drawing_number 4BV2 / 4BV4 as printed —
Identity / construction Totally Enclosed Fan Cooled Capacitor-Start & Run Type; Squirrel-Cage Rotor as printed —
Identity / date_as_printed 01.10.09 as printed —
Drawing / Overall axial length 489 drawing units; not explicitly stated on this sheet C1
Drawing / Flange face to fan end 429 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft extension 60 drawing units; not explicitly stated on this sheet C1
Drawing / Key length callout 40 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to terminal enclosure outer edge 236 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to cable-entry axis 147 drawing units; not explicitly stated on this sheet C1
Drawing / Cable-entry diameter Ø22 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft diameter and fit Ø28 j6 drawing units; not explicitly stated on this sheet C1
Drawing / Key width 8 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-and-key top height 31 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft keyseat lower-height callout 24 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-end thread and depth M10 TAP DEEP 15 drawing units; not explicitly stated on this sheet C1
Drawing / Flange outer diameter Ø250 drawing units; not explicitly stated on this sheet C1
Drawing / Flange pilot diameter and fit Ø180 h7 drawing units; not explicitly stated on this sheet C1
Drawing / Flange bolt pitch-circle diameter Ø215 drawing units; not explicitly stated on this sheet C1
Drawing / Flange thickness 16 drawing units; not explicitly stated on this sheet C1
Drawing / Flange register projection 4 drawing units; not explicitly stated on this sheet C1
Drawing / Side-view vertical envelope including projections 300 drawing units; not explicitly stated on this sheet C2
Drawing / Flange bolt holes 4-Ø15 Holes as printed C1
Drawing / Flange hole angular offset 45 degrees C1
Drawing note / 1 FLANGE MOUNTED IM3001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 FOR BELT OR DIRECT DRIVE. as printed —
Drawing note / 4 Dimensional units are not explicitly stated on this sheet; values and tolerances are transcribed as printed. as printed —
Drawing note / 5 SYNCH RPM is synchronous speed, not a measured full-load speed. Slash-separated ratings are retained as alternatives, not numeric ranges. as printed —

Electrical ratings as printed — P048, 4BV2 , 4BV4.pdf, page 1

Conditions for this section:

  • C1: Each row belongs only to this exact drawing and mounting; slash-separated alternatives are retained as printed. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 4 kW 5.5 HP 3000 rpm (synchronous) C1
2 4 poles 4 kW 5.5 HP 1500 rpm (synchronous) C1

Datasheet-491.pdf

Associated selection rows: 420

Datasheet-491.pdf.

Source differences and limitations

  • Website/source difference — VOLTAGE: website 240; PDF page 1 240/480. Website row IDs: 420. Neither is automatically substituted for the other.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BECY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 4 —
VOLTAGE 240/480 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 2 —
FRAME D112M —
SPEED / SYNCHRONOUS 3000 (rpm) —
SPEED / FULL LOAD 2900 (rpm) —
CURRENT / FULL LOAD 25 / 12.5 (Amps) —
CURRENT / LOCKED ROTOR 550 % —
TORQUE / FULL LOAD TORQUE 13.1 (Nm) —
TORQUE / STARTING TORQUE 160 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 220 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 74.6 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 93 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING 44 —
WEIGHT OF MOTOR 43.2 kgs —
BEARINGS / DRIVE END 6306ZZ —
BEARINGS / NON DRIVE END 6306 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

TECO Single Phase Cast Iron Frame – BECY — technical configurations, part 2 of 2

Product: P048. Product page: https://electricmotors.teco.com.au/product/teco-single-phase-cast-iron-frame-motors/

Datasheet-498.pdf

Associated selection rows: 421

Datasheet-498.pdf.

Source differences and limitations

  • Website/source difference — VOLTAGE: website 240; PDF page 1 240/480. Website row IDs: 421. Neither is automatically substituted for the other.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BECY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 4 —
VOLTAGE 240/480 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 4 —
FRAME D112M —
SPEED / SYNCHRONOUS 1500 (rpm) —
SPEED / FULL LOAD 1440 (rpm) —
CURRENT / FULL LOAD 25 / 12.5 (Amps) —
CURRENT / LOCKED ROTOR 540 % —
TORQUE / FULL LOAD TORQUE 26.5 (Nm) —
TORQUE / STARTING TORQUE 190 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 210 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 79 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 87 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING 44 —
WEIGHT OF MOTOR 47.4 kgs —
BEARINGS / DRIVE END 6306ZZ —
BEARINGS / NON DRIVE END 6306 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

5.5BE2-7.5BE2-5.5BE4.pdf

Associated selection rows: 422

5.5BE2-7.5BE2-5.5BE4.pdf.

Source page 1

Conditions for this section:

  • C1: Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

  • C2: Applies to the view and mounting printed on this source only. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

Specification Value Unit / basis Conditions
Identity / drawing_title OUTLINE DIMENSIONS — 1-PHASE INDUCTION MOTOR as printed —
Identity / frame D132S as printed —
Identity / drawing_number 5.5BE2 / 7.5BE2 / 5.5BE4 as printed —
Identity / construction Totally Enclosed Fan Cooled Capacitor-Start & Run Type; Squirrel-Cage Rotor as printed —
Identity / date_as_printed 01.10.09 as printed —
Drawing / Overall axial length 508 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft extension 80 drawing units; not explicitly stated on this sheet C1
Drawing / Key length callout 56 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to terminal enclosure outer edge 294 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to cable-entry axis 192 drawing units; not explicitly stated on this sheet C1
Drawing / Cable-entry diameter Ø22 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft diameter and fit Ø38 k6 drawing units; not explicitly stated on this sheet C1
Drawing / Key width 10 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-and-key top height 41 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft keyseat lower-height callout 33 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-end thread and depth M12 TAP DEEP 18 drawing units; not explicitly stated on this sheet C1
Drawing / Height from foot mounting plane to topmost drawn projection 310 drawing units; not explicitly stated on this sheet C2
Drawing / Shaft height and tolerance 132 +0/-0.5 drawing units; not explicitly stated on this sheet C1
Drawing / Transverse mounting-hole centres 216 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall width 250 drawing units; not explicitly stated on this sheet C1
Drawing / Axial mounting-hole centres 140 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall axial length 175 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft shoulder to nearer foot-hole centre 89 drawing units; not explicitly stated on this sheet C1
Drawing / Rear foot-hole centre to fan end 199 drawing units; not explicitly stated on this sheet C1
Drawing / Foot slot-group width callout 45 drawing units; not explicitly stated on this sheet C1
Drawing / Foot thickness callout 16 drawing units; not explicitly stated on this sheet C1
Drawing / Lower terminal enclosure height above mounting plane 54 drawing units; not explicitly stated on this sheet C1
Drawing / Foot mounting holes 4-Ø12 Holes drawing units; not explicitly stated on this sheet C1
Drawing / Front-view body width callout 273 drawing units; not explicitly stated on this sheet C1
Drawing note / 1 FOOT MOUNTED IM1001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 FOR BELT OR DIRECT DRIVE. as printed —
Drawing note / 4 Dimensional units are not explicitly stated on this sheet; values and tolerances are transcribed as printed. as printed —
Drawing note / 5 SYNCH RPM is synchronous speed, not a measured full-load speed. Slash-separated ratings are retained as alternatives, not numeric ranges. as printed —
Drawing note / 6 Another collected PDF has the same visible BECY D132S BE ratings and selected dimensions but a different file identity. Both sources are retained; no hash-based identity is inferred from visual similarity. as printed —

Electrical ratings as printed — P048, 5.5BE2-7.5BE2-5.5BE4.pdf, page 1

Conditions for this section:

  • C1: Each row belongs only to this exact drawing and mounting; slash-separated alternatives are retained as printed. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 5.5/7.5 kW 7.5/10 HP 3000 rpm (synchronous) C1
2 4 poles 5.5 kW 7.5 HP 1500 rpm (synchronous) C1

Datasheet-493.pdf

Associated selection rows: 422

Datasheet-493.pdf.

Source differences and limitations

  • Website/source difference — VOLTAGE: website 240; PDF page 1 240/480. Website row IDs: 422. Neither is automatically substituted for the other.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BECY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 7.5 —
VOLTAGE 240/480 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 2 —
FRAME D132M —
SPEED / SYNCHRONOUS 3000 (rpm) —
SPEED / FULL LOAD 2930 (rpm) —
CURRENT / FULL LOAD 40 / 20 (Amps) —
CURRENT / LOCKED ROTOR 680 % —
TORQUE / FULL LOAD TORQUE 24.5 (Nm) —
TORQUE / STARTING TORQUE 240 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 230 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 81.2 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 99 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING 44 —
WEIGHT OF MOTOR 80 kgs —
BEARINGS / DRIVE END 6308ZZ —
BEARINGS / NON DRIVE END 6306 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

7.5BE4.pdf

Associated selection rows: 423

PDFdrawings-500.zip > 132M FRAME/7.5BE4.pdf.

Source differences and limitations

  • 7.5BE4 prints axial mounting-hole centres 170 and overall length 546. Its printed axial chain 80 + 89 + 170 + 199 totals 538, not 546; 7.5BF4 separately prints 178 for mounting-hole centres. All source values retained; no correction from another mounting inferred.

Source page 1

Conditions for this section:

  • C1: Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

  • C2: Applies to the view and mounting printed on this source only. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

Specification Value Unit / basis Conditions
Identity / drawing_title OUTLINE DIMENSIONS — 1-PHASE INDUCTION MOTOR as printed —
Identity / frame D132M as printed —
Identity / drawing_number 7.5BE4 as printed —
Identity / construction Totally Enclosed Fan Cooled Capacitor-Start & Run Type; Squirrel-Cage Rotor as printed —
Identity / date_as_printed 01.10.09 as printed —
Drawing / Overall axial length 546 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft extension 80 drawing units; not explicitly stated on this sheet C1
Drawing / Key length callout 56 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to terminal enclosure outer edge 294 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to cable-entry axis 192 drawing units; not explicitly stated on this sheet C1
Drawing / Cable-entry diameter Ø22 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft diameter and fit Ø38 k6 drawing units; not explicitly stated on this sheet C1
Drawing / Key width 10 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-and-key top height 41 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft keyseat lower-height callout 33 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-end thread and depth M12 TAP DEEP 18 drawing units; not explicitly stated on this sheet C1
Drawing / Height from foot mounting plane to topmost drawn projection 310 drawing units; not explicitly stated on this sheet C2
Drawing / Shaft height and tolerance 132 +0/-0.5 drawing units; not explicitly stated on this sheet C1
Drawing / Transverse mounting-hole centres 216 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall width 250 drawing units; not explicitly stated on this sheet C1
Drawing / Axial mounting-hole centres 170 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall axial length 212 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft shoulder to nearer foot-hole centre 89 drawing units; not explicitly stated on this sheet C1
Drawing / Rear foot-hole centre to fan end 199 drawing units; not explicitly stated on this sheet C1
Drawing / Foot slot-group width callout 45 drawing units; not explicitly stated on this sheet C1
Drawing / Foot thickness callout 16 drawing units; not explicitly stated on this sheet C1
Drawing / Lower terminal enclosure height above mounting plane 54 drawing units; not explicitly stated on this sheet C1
Drawing / Foot mounting holes 4-Ø12 Holes drawing units; not explicitly stated on this sheet C1
Drawing / Front-view body width callout 273 drawing units; not explicitly stated on this sheet C1
Drawing note / 1 FOOT MOUNTED IM1001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 FOR BELT OR DIRECT DRIVE. as printed —
Drawing note / 4 Dimensional units are not explicitly stated on this sheet; values and tolerances are transcribed as printed. as printed —
Drawing note / 5 SYNCH RPM is synchronous speed, not a measured full-load speed. Slash-separated ratings are retained as alternatives, not numeric ranges. as printed —
Drawing note / 6 The first electrical-rating row is blank; no 2-pole rating is inferred from it. as printed —

Electrical ratings as printed — P048, 7.5BE4.pdf, page 1

Conditions for this section:

  • C1: Each row belongs only to this exact drawing and mounting; slash-separated alternatives are retained as printed. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 4 poles 7.5 kW 10 HP 1500 rpm (synchronous) C1

7.5BF4.pdf

Associated selection rows: 423

PDFdrawings-500.zip > 132M FRAME/7.5BF4.pdf.

Source page 1

Conditions for this section:

  • C1: Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

  • C2: Applies to the view and mounting printed on this source only. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

Specification Value Unit / basis Conditions
Identity / drawing_title OUTLINE DIMENSIONS — 1-PHASE INDUCTION MOTOR as printed —
Identity / frame D132M as printed —
Identity / drawing_number 7.5BF4 as printed —
Identity / construction Totally Enclosed Fan Cooled Capacitor-Start & Run Type; Squirrel-Cage Rotor as printed —
Identity / date_as_printed 01.10.09 as printed —
Drawing / Overall axial length 596 drawing units; not explicitly stated on this sheet C1
Drawing / Flange face to fan end 516 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft extension 80 drawing units; not explicitly stated on this sheet C1
Drawing / Key length callout 56 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to terminal enclosure outer edge 294 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to cable-entry axis 192 drawing units; not explicitly stated on this sheet C1
Drawing / Cable-entry diameter Ø28 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft diameter and fit Ø38 k6 drawing units; not explicitly stated on this sheet C1
Drawing / Key width 10 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-and-key top height 41 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft keyseat lower-height callout 33 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-end thread and depth M12 TAP DEEP 18 drawing units; not explicitly stated on this sheet C1
Drawing / Flange outer diameter Ø300 drawing units; not explicitly stated on this sheet C1
Drawing / Flange pilot diameter and fit Ø230 h7 drawing units; not explicitly stated on this sheet C1
Drawing / Flange bolt pitch-circle diameter Ø265 drawing units; not explicitly stated on this sheet C1
Drawing / Flange thickness 20 drawing units; not explicitly stated on this sheet C1
Drawing / Flange register projection 4 drawing units; not explicitly stated on this sheet C1
Drawing / Height from foot mounting plane to topmost drawn projection 310 drawing units; not explicitly stated on this sheet C2
Drawing / Flange bolt holes 4-Ø15 Holes as printed C1
Drawing / Flange hole angular offset 45 degrees C1
Drawing / Additional flange tapped holes 2-M12 Tap as printed C1
Drawing / Shaft height and tolerance 132 +0/-0.5 drawing units; not explicitly stated on this sheet C1
Drawing / Transverse mounting-hole centres 216 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall width 250 drawing units; not explicitly stated on this sheet C1
Drawing / Axial mounting-hole centres 178 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall axial length 212 drawing units; not explicitly stated on this sheet C1
Drawing / Flange face to nearer foot-hole centre 139 drawing units; not explicitly stated on this sheet C1
Drawing / Foot slot-group width callout 45 drawing units; not explicitly stated on this sheet C1
Drawing / Foot thickness callout 16 drawing units; not explicitly stated on this sheet C1
Drawing / Lower terminal enclosure height above mounting plane 54 drawing units; not explicitly stated on this sheet C1
Drawing / Foot mounting holes 4-Ø12 Holes drawing units; not explicitly stated on this sheet C1
Drawing note / 1 FOOT & FLANGE MOUNTED IM2001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 FOR BELT OR DIRECT DRIVE. as printed —
Drawing note / 4 Dimensional units are not explicitly stated on this sheet; values and tolerances are transcribed as printed. as printed —
Drawing note / 5 SYNCH RPM is synchronous speed, not a measured full-load speed. Slash-separated ratings are retained as alternatives, not numeric ranges. as printed —
Drawing note / 6 The first electrical-rating row is blank; no 2-pole rating is inferred from it. as printed —

Electrical ratings as printed — P048, 7.5BF4.pdf, page 1

Conditions for this section:

  • C1: Each row belongs only to this exact drawing and mounting; slash-separated alternatives are retained as printed. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 4 poles 7.5 kW 10 HP 1500 rpm (synchronous) C1

7.5BV4.pdf

Associated selection rows: 423

PDFdrawings-500.zip > 132M FRAME/7.5BV4.pdf.

Source page 1

Conditions for this section:

  • C1: Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

  • C2: Applies to the view and mounting printed on this source only. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

Specification Value Unit / basis Conditions
Identity / drawing_title OUTLINE DIMENSIONS — 1-PHASE INDUCTION MOTOR as printed —
Identity / frame D132M as printed —
Identity / drawing_number 7.5BV4 as printed —
Identity / construction Totally Enclosed Fan Cooled Capacitor-Start & Run Type; Squirrel-Cage Rotor as printed —
Identity / date_as_printed 01.10.09 as printed —
Drawing / Overall axial length 546 drawing units; not explicitly stated on this sheet C1
Drawing / Flange face to fan end 466 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft extension 80 drawing units; not explicitly stated on this sheet C1
Drawing / Key length callout 56 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to terminal enclosure outer edge 294 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to cable-entry axis 192 drawing units; not explicitly stated on this sheet C1
Drawing / Cable-entry diameter Ø28 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft diameter and fit Ø38 k6 drawing units; not explicitly stated on this sheet C1
Drawing / Key width 10 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-and-key top height 41 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft keyseat lower-height callout 33 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-end thread and depth M12 TAP DEEP 18 drawing units; not explicitly stated on this sheet C1
Drawing / Flange outer diameter Ø300 drawing units; not explicitly stated on this sheet C1
Drawing / Flange pilot diameter and fit Ø230 h7 drawing units; not explicitly stated on this sheet C1
Drawing / Flange bolt pitch-circle diameter Ø265 drawing units; not explicitly stated on this sheet C1
Drawing / Flange thickness 20 drawing units; not explicitly stated on this sheet C1
Drawing / Flange register projection 4 drawing units; not explicitly stated on this sheet C1
Drawing / Side-view vertical envelope including projections 336 drawing units; not explicitly stated on this sheet C2
Drawing / Flange bolt holes 4-Ø15 Holes as printed C1
Drawing / Flange hole angular offset 45 degrees C1
Drawing / Additional flange tapped holes 2-M12 Tap as printed C1
Drawing note / 1 FLANGE MOUNTED IM3001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 FOR BELT OR DIRECT DRIVE. as printed —
Drawing note / 4 Dimensional units are not explicitly stated on this sheet; values and tolerances are transcribed as printed. as printed —
Drawing note / 5 SYNCH RPM is synchronous speed, not a measured full-load speed. Slash-separated ratings are retained as alternatives, not numeric ranges. as printed —
Drawing note / 6 The first electrical-rating row is blank; no 2-pole rating is inferred from it. as printed —

Electrical ratings as printed — P048, 7.5BV4.pdf, page 1

Conditions for this section:

  • C1: Each row belongs only to this exact drawing and mounting; slash-separated alternatives are retained as printed. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 4 poles 7.5 kW 10 HP 1500 rpm (synchronous) C1

Datasheet-500.pdf

Associated selection rows: 423

Datasheet-500.pdf.

Source differences and limitations

  • Website/source difference — VOLTAGE: website 240; PDF page 1 240/480. Website row IDs: 423. Neither is automatically substituted for the other.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BECY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 7.5 —
VOLTAGE 240/480 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 4 —
FRAME D132M —
SPEED / SYNCHRONOUS 1500 (rpm) —
SPEED / FULL LOAD 1455 (rpm) —
CURRENT / FULL LOAD 42 / 21 (Amps) —
CURRENT / LOCKED ROTOR 530 % —
TORQUE / FULL LOAD TORQUE 49 (Nm) —
TORQUE / STARTING TORQUE 210 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 180 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 80.5 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 92 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING 44 —
WEIGHT OF MOTOR 81 kgs —
BEARINGS / DRIVE END 6308ZZ —
BEARINGS / NON DRIVE END 6306 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

5.5BE2 , 7.5BE2 , 5.5BE4.pdf

Associated selection rows: 424, 425

PDFdrawings-499.zip > 132S FRAME/5.5BE2 , 7.5BE2 , 5.5BE4.pdf.

Source page 1

Conditions for this section:

  • C1: Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

  • C2: Applies to the view and mounting printed on this source only. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

Specification Value Unit / basis Conditions
Identity / drawing_title OUTLINE DIMENSIONS — 1-PHASE INDUCTION MOTOR as printed —
Identity / frame D132S as printed —
Identity / drawing_number 5.5BE2 / 7.5BE2 / 5.5BE4 as printed —
Identity / construction Totally Enclosed Fan Cooled Capacitor-Start & Run Type; Squirrel-Cage Rotor as printed —
Identity / date_as_printed 01.10.09 as printed —
Drawing / Overall axial length 508 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft extension 80 drawing units; not explicitly stated on this sheet C1
Drawing / Key length callout 56 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to terminal enclosure outer edge 294 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to cable-entry axis 192 drawing units; not explicitly stated on this sheet C1
Drawing / Cable-entry diameter Ø22 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft diameter and fit Ø38 k6 drawing units; not explicitly stated on this sheet C1
Drawing / Key width 10 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-and-key top height 41 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft keyseat lower-height callout 33 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-end thread and depth M12 TAP DEEP 18 drawing units; not explicitly stated on this sheet C1
Drawing / Height from foot mounting plane to topmost drawn projection 310 drawing units; not explicitly stated on this sheet C2
Drawing / Shaft height and tolerance 132 +0/-0.5 drawing units; not explicitly stated on this sheet C1
Drawing / Transverse mounting-hole centres 216 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall width 250 drawing units; not explicitly stated on this sheet C1
Drawing / Axial mounting-hole centres 140 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall axial length 175 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft shoulder to nearer foot-hole centre 89 drawing units; not explicitly stated on this sheet C1
Drawing / Rear foot-hole centre to fan end 199 drawing units; not explicitly stated on this sheet C1
Drawing / Foot slot-group width callout 45 drawing units; not explicitly stated on this sheet C1
Drawing / Foot thickness callout 16 drawing units; not explicitly stated on this sheet C1
Drawing / Lower terminal enclosure height above mounting plane 54 drawing units; not explicitly stated on this sheet C1
Drawing / Foot mounting holes 4-Ø12 Holes drawing units; not explicitly stated on this sheet C1
Drawing / Front-view body width callout 273 drawing units; not explicitly stated on this sheet C1
Drawing note / 1 FOOT MOUNTED IM1001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 FOR BELT OR DIRECT DRIVE. as printed —
Drawing note / 4 Dimensional units are not explicitly stated on this sheet; values and tolerances are transcribed as printed. as printed —
Drawing note / 5 SYNCH RPM is synchronous speed, not a measured full-load speed. Slash-separated ratings are retained as alternatives, not numeric ranges. as printed —
Drawing note / 6 Another collected PDF has the same visible BECY D132S BE ratings and selected dimensions but a different file identity. Both sources are retained; no hash-based identity is inferred from visual similarity. as printed —

Electrical ratings as printed — P048, 5.5BE2 , 7.5BE2 , 5.5BE4.pdf, page 1

Conditions for this section:

  • C1: Each row belongs only to this exact drawing and mounting; slash-separated alternatives are retained as printed. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 5.5/7.5 kW 7.5/10 HP 3000 rpm (synchronous) C1
2 4 poles 5.5 kW 7.5 HP 1500 rpm (synchronous) C1

5.5BF2 , 7.5BF2 , 5.5BF4.pdf

Associated selection rows: 424, 425

PDFdrawings-499.zip > 132S FRAME/5.5BF2 , 7.5BF2 , 5.5BF4.pdf.

Source page 1

Conditions for this section:

  • C1: Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

  • C2: Applies to the view and mounting printed on this source only. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

Specification Value Unit / basis Conditions
Identity / drawing_title OUTLINE DIMENSIONS — 1-PHASE INDUCTION MOTOR as printed —
Identity / frame D132S as printed —
Identity / drawing_number 5.5BF2 / 7.5BF2 / 5.5BF4 as printed —
Identity / construction Totally Enclosed Fan Cooled Capacitor-Start & Run Type; Squirrel-Cage Rotor as printed —
Identity / date_as_printed 01.10.09 as printed —
Drawing / Overall axial length 558 drawing units; not explicitly stated on this sheet C1
Drawing / Flange face to fan end 478 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft extension 80 drawing units; not explicitly stated on this sheet C1
Drawing / Key length callout 56 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to terminal enclosure outer edge 294 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to cable-entry axis 192 drawing units; not explicitly stated on this sheet C1
Drawing / Cable-entry diameter Ø28 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft diameter and fit Ø38 k6 drawing units; not explicitly stated on this sheet C1
Drawing / Key width 10 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-and-key top height 41 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft keyseat lower-height callout 33 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-end thread and depth M12 TAP DEEP 18 drawing units; not explicitly stated on this sheet C1
Drawing / Flange outer diameter Ø300 drawing units; not explicitly stated on this sheet C1
Drawing / Flange pilot diameter and fit Ø230 h7 drawing units; not explicitly stated on this sheet C1
Drawing / Flange bolt pitch-circle diameter Ø265 drawing units; not explicitly stated on this sheet C1
Drawing / Flange thickness 20 drawing units; not explicitly stated on this sheet C1
Drawing / Flange register projection 4 drawing units; not explicitly stated on this sheet C1
Drawing / Height from foot mounting plane to topmost drawn projection 310 drawing units; not explicitly stated on this sheet C2
Drawing / Flange bolt holes 4-Ø15 Holes as printed C1
Drawing / Flange hole angular offset 45 degrees C1
Drawing / Additional flange tapped holes 2-M12 Tap as printed C1
Drawing / Shaft height and tolerance 132 +0/-0.5 drawing units; not explicitly stated on this sheet C1
Drawing / Transverse mounting-hole centres 216 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall width 250 drawing units; not explicitly stated on this sheet C1
Drawing / Axial mounting-hole centres 140 drawing units; not explicitly stated on this sheet C1
Drawing / Foot overall axial length 175 drawing units; not explicitly stated on this sheet C1
Drawing / Flange face to nearer foot-hole centre 139 drawing units; not explicitly stated on this sheet C1
Drawing / Foot slot-group width callout 45 drawing units; not explicitly stated on this sheet C1
Drawing / Foot thickness callout 16 drawing units; not explicitly stated on this sheet C1
Drawing / Lower terminal enclosure height above mounting plane 54 drawing units; not explicitly stated on this sheet C1
Drawing / Foot mounting holes 4-Ø12 Holes drawing units; not explicitly stated on this sheet C1
Drawing note / 1 FOOT & FLANGE MOUNTED IM2001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 FOR BELT OR DIRECT DRIVE. as printed —
Drawing note / 4 Dimensional units are not explicitly stated on this sheet; values and tolerances are transcribed as printed. as printed —
Drawing note / 5 SYNCH RPM is synchronous speed, not a measured full-load speed. Slash-separated ratings are retained as alternatives, not numeric ranges. as printed —

Electrical ratings as printed — P048, 5.5BF2 , 7.5BF2 , 5.5BF4.pdf, page 1

Conditions for this section:

  • C1: Each row belongs only to this exact drawing and mounting; slash-separated alternatives are retained as printed. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 5.5/7.5 kW 7.5/10 HP 3000 rpm (synchronous) C1
2 4 poles 5.5 kW 7.5 HP 1500 rpm (synchronous) C1

5.5BV2 , 7.5BV2 , 5.5BV4.pdf

Associated selection rows: 424, 425

PDFdrawings-499.zip > 132S FRAME/5.5BV2 , 7.5BV2 , 5.5BV4.pdf.

Source page 1

Conditions for this section:

  • C1: Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

  • C2: Applies to the view and mounting printed on this source only. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.

Specification Value Unit / basis Conditions
Identity / drawing_title OUTLINE DIMENSIONS — 1-PHASE INDUCTION MOTOR as printed —
Identity / frame D132S as printed —
Identity / drawing_number 5.5BV2 / 7.5BV2 / 5.5BV4 as printed —
Identity / construction Totally Enclosed Fan Cooled Capacitor-Start & Run Type; Squirrel-Cage Rotor as printed —
Identity / date_as_printed 01.10.09 as printed —
Drawing / Overall axial length 508 drawing units; not explicitly stated on this sheet C1
Drawing / Flange face to fan end 428 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft extension 80 drawing units; not explicitly stated on this sheet C1
Drawing / Key length callout 56 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to terminal enclosure outer edge 294 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-centre to cable-entry axis 192 drawing units; not explicitly stated on this sheet C1
Drawing / Cable-entry diameter Ø28 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft diameter and fit Ø38 k6 drawing units; not explicitly stated on this sheet C1
Drawing / Key width 10 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-and-key top height 41 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft keyseat lower-height callout 33 drawing units; not explicitly stated on this sheet C1
Drawing / Shaft-end thread and depth M12 TAP DEEP 18 drawing units; not explicitly stated on this sheet C1
Drawing / Flange outer diameter Ø300 drawing units; not explicitly stated on this sheet C1
Drawing / Flange pilot diameter and fit Ø230 h7 drawing units; not explicitly stated on this sheet C1
Drawing / Flange bolt pitch-circle diameter Ø265 drawing units; not explicitly stated on this sheet C1
Drawing / Flange thickness 20 drawing units; not explicitly stated on this sheet C1
Drawing / Flange register projection 4 drawing units; not explicitly stated on this sheet C1
Drawing / Side-view vertical envelope including projections 336 drawing units; not explicitly stated on this sheet C2
Drawing / Flange bolt holes 4-Ø15 Holes as printed C1
Drawing / Flange hole angular offset 45 degrees C1
Drawing / Additional flange tapped holes 2-M12 Tap as printed C1
Drawing note / 1 FLANGE MOUNTED IM3001. as printed —
Drawing note / 2 TYPICAL DIMENSIONS ONLY. FOR CERTIFIED DIMENSIONS REFER TO TECO. as printed —
Drawing note / 3 FOR BELT OR DIRECT DRIVE. as printed —
Drawing note / 4 Dimensional units are not explicitly stated on this sheet; values and tolerances are transcribed as printed. as printed —
Drawing note / 5 SYNCH RPM is synchronous speed, not a measured full-load speed. Slash-separated ratings are retained as alternatives, not numeric ranges. as printed —

Electrical ratings as printed — P048, 5.5BV2 , 7.5BV2 , 5.5BV4.pdf, page 1

Conditions for this section:

  • C1: Each row belongs only to this exact drawing and mounting; slash-separated alternatives are retained as printed. Ratings and named mechanical dimensions apply only to this source configuration. Refer to the drawing for graphical shape and unnamed symbols. Typical dimensions only; refer to TECO for certified dimensions.
Configuration / printed row POLES kW HP SYNCH RPM Conditions
1 2 poles 5.5/7.5 kW 7.5/10 HP 3000 rpm (synchronous) C1
2 4 poles 5.5 kW 7.5 HP 1500 rpm (synchronous) C1

Datasheet-492.pdf

Associated selection rows: 424

Datasheet-492.pdf.

Source differences and limitations

  • Website/source difference — VOLTAGE: website 240; PDF page 1 240/480. Website row IDs: 424. Neither is automatically substituted for the other.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BECY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 5.5 —
VOLTAGE 240/480 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 2 —
FRAME D132S —
SPEED / SYNCHRONOUS 3000 (rpm) —
SPEED / FULL LOAD 2930 (rpm) —
CURRENT / FULL LOAD 30 / 15 (Amps) —
CURRENT / LOCKED ROTOR 800 % —
TORQUE / FULL LOAD TORQUE 18 (Nm) —
TORQUE / STARTING TORQUE 280 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 260 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 79.2 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 96 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING 44 —
WEIGHT OF MOTOR 77 kgs —
BEARINGS / DRIVE END 6308ZZ —
BEARINGS / NON DRIVE END 6306 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

Datasheet-499.pdf

Associated selection rows: 425

Datasheet-499.pdf.

Source differences and limitations

  • Website/source difference — VOLTAGE: website 240; PDF page 1 240/480. Website row IDs: 425. Neither is automatically substituted for the other.

Source page 1

Specification Value Unit / basis Conditions
MOTOR SERIES TECO BECY SINGLE PHASE TEFC —
START METHOD DIRECT ONLINE —
KW RATING 5.5 —
VOLTAGE 240/480 (V) —
PHASES 1 —
FREQUENCY 50 (Hz) —
NO OF POLES 4 —
FRAME D132S —
SPEED / SYNCHRONOUS 1500 (rpm) —
SPEED / FULL LOAD 1465 (rpm) —
CURRENT / FULL LOAD 33 / 16.5 (Amps) —
CURRENT / LOCKED ROTOR 590 % —
TORQUE / FULL LOAD TORQUE 36 (Nm) —
TORQUE / STARTING TORQUE 250 % —
TORQUE / MINIMUM TORQUE Not stated (blank in source) % —
TORQUE / BREAKDOWN TORQUE 220 % —
ROTOR INERTIA (J = GD²/4) Not stated (blank in source) (Kgm²) —
EFFICIENCY / 100% LOAD 80.5 % —
EFFICIENCY / 75% LOAD Not stated (blank in source) % —
EFFICIENCY / 50% LOAD Not stated (blank in source) % —
POWER FACTOR / 100% LOAD 88 % —
POWER FACTOR / 75% LOAD Not stated (blank in source) % —
POWER FACTOR / 50% LOAD Not stated (blank in source) % —
INSULATION CLASS Not stated (blank in source) —
ENCLOSURE TYPE TEFC —
IP RATING 44 —
WEIGHT OF MOTOR 75 kgs —
BEARINGS / DRIVE END 6308ZZ —
BEARINGS / NON DRIVE END 6306 ZZ —
NO LOAD SOUND PRESSURE LEVEL @ 1M Not stated (blank in source) dbA —
DESIGN STANDARD AS1359 —
CERTIFICATION Not stated (blank in source) —
TEMPERATURE RISE ABOVE AMBIENT Not stated (blank in source) —

Downloads, customisation and support

Download our single-phase catalogue. Individual datasheets, PDF archives and CAD downloads are linked with the selections above. We can help with mounting options, terminal-box arrangements, 3D files and certified dimensions.

No separate operating manual is attached in the collected BECY product pack. Contact our team for the installation instructions and modifications relevant to your motor. Historical catalogue contact details are replaced here by our current contact-page link.

Company documents

These company references have their own scope; they are not motor-specific approvals.

Source editions: TECO1PH-032014 catalogue and individual configuration sheets collected 15 October 2026. Product-page wording checked 27 October 2026. Source differences and original document identities remain traceable.